A114 of 18
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

A1 · Lesson 14 · Tolerance, significant figures and error

Why a 5% resistor is fine

Measure ten resistors marked 10 kΩ with a gold band and you'll get ten different readings, anywhere from 9.5 kΩ to 10.5 kΩ. The gold band means ±5%. Yet circuits built from parts like these work, and work repeatably. How much does that 5% really matter?

Play

  • This divider splits 10 V between two 10 kΩ resistors. Each slider covers that resistor's whole ±5% range.
  • Find the settings that make the output as high as possible, and as low as possible.
  • Then set both resistors 5% high together, and both 5% low together. What happens to the output?

Predict

Each resistor can be up to 5% off. How far from 5 V can the output get?

Name it

Tolerance, worst cases and honest digits

A part's tolerance says how far its real value may be from the value printed on it. A 10 kΩ ±5% resistor is somewhere from 9.5 kΩ to 10.5 kΩ.

The worst case for a circuit comes from pushing each part to whichever end of its range hurts most. Two rules give the worst case quickly:

  • When quantities multiply or divide, their percentage errors add. Current is I=V/R, so a voltage known to 2% across a 5% resistor gives a current known to 7%.
  • When quantities add or subtract, their absolute errors add. Two 10 kΩ ±5% resistors in series make 20 kΩ ± 1 kΩ, still ±5%.

The divider in the sim does better than the first rule suggests. Its output is Vout=V⋅R2/(R1+R2), and each resistor appears both on top and on the bottom, so half of each error cancels: 2.5% + 2.5% = 5% in the worst case.

Significant figures are how you say how well you know a number. If you measure 3.3 V and 0.47 mA, the resistance is 3.3/0.00047=7021.27… Ω, but the inputs only had two digits each, so the honest answer is 7.0 kΩ. Writing 7021.27 Ω claims a precision you don't have.

Standard values are spaced to match tolerances. The E12 series, for 10% parts, has twelve values per decade (1.0, 1.2, 1.5, 1.8, 2.2, 2.7, 3.3, 3.9, 4.7, 5.6, 6.8 and 8.2, times any power of ten), each about 21% above the last. The ±10% band around each value overlaps or nearly meets its neighbors', so between them they cover almost every value. The E24 series does the same for 5% parts with 24 values per decade, and E96 for 1% parts with 96.

Most good circuits are designed so that their behavior depends on ratios of parts, or on feedback, more than on any one part's exact value. That's why a 5% resistor is usually fine, and why it's worth asking which parts really need 1%.

Worked example

A 3.3 V regulator, accurate to ±2%, feeds a 10 kΩ ±1% resistor. What range can the current fall in?

Show the solution
  1. Highest current. It comes from the highest voltage and the lowest resistance: Imax⁡=3.3×1.0210000×0.99=3.3669900=0.340mA
  2. Lowest current. It comes from the opposite corner: Imin⁡=3.3×0.9810000×1.01=3.23410100=0.320mA
  3. Compare with the nominal value. The nominal value is 0.330 mA, so the current is within about ±3%: the two tolerances roughly add.

Answer the current can fall anywhere from 0.320 to 0.340 mA, about ±3% around 0.330 mA.

Worked example

A meter on its 20 V range reads 12.06 V. Its accuracy is ±(0.5% of the reading + 2 digits), and the last digit is 0.01 V. How should you report the voltage?

Show the solution
  1. Percent of the reading. 0.005×12.06V=0.060V
  2. The digits. Two digits of the last place is 2×0.01V=0.02V
  3. Add them. Together they come to ±0.08 V.
  4. Report it. Writing 12.060 V would claim a precision the meter can't deliver, and writing 12 V would throw away what it does tell you.

Answer report 12.06±0.08 V.

Check

A resistor is marked 4.7 kΩ with a tolerance of ±1%.

(a)

What is the lowest value it could really have?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

And the highest?

Check

A divider splits 9 V between two equal resistors, each with a tolerance of ±1%. What is the highest the output could be?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

You measure 3.3 V across a resistor and 0.47 mA through it. Which is the best way to report its resistance?

Check

Your design calls for a 3.5 kΩ resistor, and you only stock E12 values. Which do you pick?

Check

A 3.9 kΩ and a 1.5 kΩ resistor, each with a tolerance of ±5%, are connected in series. What is the highest the total resistance could be?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A meter on its 20 V range reads 3.26 V. Its accuracy is ±(0.5% of the reading + 5 digits), and its last digit is 0.01 V.

(a)

What is the largest possible error, in volts?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What is that as a percentage of the reading?

Explain why

Two 5% resistors from the same reel make a divider. Why is its output often much better than 5% off?

Practice

Keep practicing

7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.