A1 · Lesson 14 · Tolerance, significant figures and error
Why a 5% resistor is fine
Measure ten resistors marked 10 kΩ with a gold band and you'll get ten different readings, anywhere from 9.5 kΩ to 10.5 kΩ. The gold band means ±5%. Yet circuits built from parts like these work, and work repeatably. How much does that 5% really matter?
Play
- This divider splits 10 V between two 10 kΩ resistors. Each slider covers that resistor's whole ±5% range.
- Find the settings that make the output as high as possible, and as low as possible.
- Then set both resistors 5% high together, and both 5% low together. What happens to the output?
Predict
Each resistor can be up to 5% off. How far from 5 V can the output get?
Up to 5%, from 4.75 V to 5.25 V. The worst case is one resistor high and the other low: with R1 at 9.5 kΩ and R2 at 10.5 kΩ, the output is 10 V × 10.5 / 20 = 5.25 V. But when both are off in the same direction, the output doesn't move at all, because it depends only on the ratio of the two resistors. Parts from the same batch, or parts warming up side by side, tend to drift together, so a real divider usually does better than its worst case.
Name it
Tolerance, worst cases and honest digits
A part's tolerance says how far its real value may be from the value printed on it. A 10 kΩ ±5% resistor is somewhere from 9.5 kΩ to 10.5 kΩ.
The worst case for a circuit comes from pushing each part to whichever end of its range hurts most. Two rules give the worst case quickly:
- When quantities multiply or divide, their percentage errors add. Current is , so a voltage known to 2% across a 5% resistor gives a current known to 7%.
- When quantities add or subtract, their absolute errors add. Two 10 kΩ ±5% resistors in series make 20 kΩ ± 1 kΩ, still ±5%.
The divider in the sim does better than the first rule suggests. Its output is , and each resistor appears both on top and on the bottom, so half of each error cancels: 2.5% + 2.5% = 5% in the worst case.
Significant figures are how you say how well you know a number. If you measure 3.3 V and 0.47 mA, the resistance is Ω, but the inputs only had two digits each, so the honest answer is 7.0 kΩ. Writing 7021.27 Ω claims a precision you don't have.
Standard values are spaced to match tolerances. The E12 series, for 10% parts, has twelve values per decade (1.0, 1.2, 1.5, 1.8, 2.2, 2.7, 3.3, 3.9, 4.7, 5.6, 6.8 and 8.2, times any power of ten), each about 21% above the last. The ±10% band around each value overlaps or nearly meets its neighbors', so between them they cover almost every value. The E24 series does the same for 5% parts with 24 values per decade, and E96 for 1% parts with 96.
Most good circuits are designed so that their behavior depends on ratios of parts, or on feedback, more than on any one part's exact value. That's why a 5% resistor is usually fine, and why it's worth asking which parts really need 1%.
Worked example
A 3.3 V regulator, accurate to ±2%, feeds a 10 kΩ ±1% resistor. What range can the current fall in?
Show the solution
- Highest current. It comes from the highest voltage and the lowest resistance:
- Lowest current. It comes from the opposite corner:
- Compare with the nominal value. The nominal value is 0.330 mA, so the current is within about ±3%: the two tolerances roughly add.
Answer the current can fall anywhere from 0.320 to 0.340 mA, about ±3% around 0.330 mA.
Worked example
A meter on its 20 V range reads 12.06 V. Its accuracy is ±(0.5% of the reading + 2 digits), and the last digit is 0.01 V. How should you report the voltage?
Show the solution
- Percent of the reading.
- The digits. Two digits of the last place is
- Add them. Together they come to ±0.08 V.
- Report it. Writing 12.060 V would claim a precision the meter can't deliver, and writing 12 V would throw away what it does tell you.
Answer report V.
Check
A resistor is marked 4.7 kΩ with a tolerance of ±1%.
(a)
What is the lowest value it could really have?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
And the highest?
Check
A divider splits 9 V between two equal resistors, each with a tolerance of ±1%. What is the highest the output could be?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
You measure 3.3 V across a resistor and 0.47 mA through it. Which is the best way to report its resistance?
Check
Your design calls for a 3.5 kΩ resistor, and you only stock E12 values. Which do you pick?
Check
A 3.9 kΩ and a 1.5 kΩ resistor, each with a tolerance of ±5%, are connected in series. What is the highest the total resistance could be?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A meter on its 20 V range reads 3.26 V. Its accuracy is ±(0.5% of the reading + 5 digits), and its last digit is 0.01 V.
(a)
What is the largest possible error, in volts?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is that as a percentage of the reading?
Explain why
Two 5% resistors from the same reel make a divider. Why is its output often much better than 5% off?
The divider's output depends on the ratio of the two resistors. Resistors made in the same batch tend to be off by similar amounts in the same direction, and when both are high or both are low by the same percentage, the ratio doesn't change. Only the difference between their errors moves the output, and for matched parts that difference is usually much smaller than either error.
Practice
Keep practicing
7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.