A3 · Problem set 5
Problem set 5: the whole course
Multi-step problems that use complex numbers the way circuits will, drawing on the whole course and especially lessons 23 to 25: three-phase arithmetic, signals at several frequencies, and notation. Each one has your own numbers.
Check
Find for , and .
(a)
What is its amplitude?
(b)
And its phase, between −180° and 180°?
Check
A 470 nF capacitor has the voltage phasor V at 50 Hz across it.
(a)
What is the magnitude of its current phasor?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And its angle?
Check
. (This is an RC voltage divider.)
(a)
What is the magnitude of ?
(b)
And its angle?
Check
A load has V and A (amplitude phasors).
(a)
What average power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is its power factor?
Check
Multiply by (angles in radians) and give the result in rectangular form.
(a)
Real part?
(b)
Imaginary part?
Check
Work out in rectangular form.
(a)
Real part?
(b)
Imaginary part?
Check
A three-phase supply has 230 V from each phase to neutral.
(a)
What is the voltage between two phases?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
By how many degrees does lead ?
Check
A building's three phases carry 12 A, 9 A and 7 A, each in phase with its own voltage.
(a)
What current flows in the neutral?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
At what angle is it, relative to phase a?
Check
A balanced three-phase load draws 20 A per line at 400 V line voltage, power factor 0.92.
(a)
What real power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What reactive power?
Check
A supply puts out 5 V DC plus a 0.5 V amplitude ripple into a 50 Ω load.
(a)
What is the RMS voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What average power does the load take?
Check
A low-pass with its corner at 200 Hz gets 1 V at 100 Hz plus 3 V at 4000 Hz.
(a)
What amplitude of the 100 Hz tone comes out?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And of the 4000 Hz tone?
Check
A phasor is written .
(a)
What angle do you give Python's cmath.rect, which wants radians?
(b)
What real part does it print?
Check
Three 20 Ω resistors are connected in a delta across a three-phase supply of 400 V (line, RMS).
(a)
What current flows in each resistor?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What current flows in each line?
(c)
What total power do they take?
Check
A power supply draws a current with a fundamental of 10 A amplitude, a third harmonic of 2 A and a fifth of 1.5 A, through a wire of 5 Ω total.
(a)
What is the RMS current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is its total harmonic distortion, in percent? (THD is the RMS of the harmonics over the RMS of the fundamental.)
(c)
What power does the wire waste?
Check
In a Y-connected load, phase 1 carries A, phase 2 carries 8 A lagging its voltage by 30° (so at ), and phase 3 carries A.
(a)
What is the real part of the neutral current, the sum of the three?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is its imaginary part?
(c)
What is its amplitude?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.