A517 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

A5 · Lesson 17 · Hyperbolic functions

The shape of a hanging power line

A power line strung between two towers doesn't hang in a parabola, though it looks like one. Its exact shape is a catenary, y=acosh⁡(x/a), built from exponentials. The same family of functions shows up when a transistor pair steers current from one side to the other, and when voltage travels along a long transmission line. They're called hyperbolic functions, and their calculus looks almost exactly like that of sine and cosine.

  • The solid curve is acosh⁡(x/a)−a, a cable hanging between towers 200 m apart, measured from its lowest point. The dashed curve is the parabola x2/2a that matches it at the bottom.
  • Change a, the ratio of the cable's tension to its weight per meter. A tighter cable has a bigger a and sags less.
  • Where do the two curves part company? For a tight cable, the parabola is almost exact; for a slack one, it isn't.

Predict

What is the slope of cosh⁡x?

Name it

The definitions

cosh⁡x=ex+e−x2,sinh⁡x=ex−e−x2,tanh⁡x=sinh⁡xcosh⁡x

cosh⁡ is even, with its minimum cosh⁡0=1; sinh⁡ is odd, through the origin; tanh⁡ climbs from −1 to 1, an S-shaped curve. For large x, both cosh⁡x and sinh⁡x are close to ex/2.

Identity and derivatives

Multiplying out the definitions gives

cosh2⁡x−sinh2⁡x=1

which is why they're "hyperbolic": the point (cosh⁡t,sinh⁡t) traces the hyperbola x2−y2=1, just as (cos⁡t,sin⁡t) traces a circle. The derivatives are

ddxsinh⁡x=cosh⁡x,ddxcosh⁡x=sinh⁡x,ddxtanh⁡x=1cosh2⁡x=1−tanh2⁡x

The inverse functions

sinh−1⁡x=ln⁡(x+x2+1) and tanh−1⁡x=12ln⁡1+x1−x (for |x|<1). They undo the hyperbolic functions the way ln⁡ undoes exp⁡.

Where they appear

  • The catenary. A flexible cable under its own weight hangs as y=acosh⁡(x/a), where a is its horizontal tension divided by its weight per meter. For a span L, the sag is a(cosh⁡L2a−1) and the cable's length is 2asinh⁡L2a.
  • The differential pair. Two matched transistors sharing a tail current I split it as ΔI=Itanh⁡vd2VT for a differential input vd. Small inputs give a linear response; large ones steer all the current to one side.
  • Long lines. Voltage along a lossy transmission line follows cosh⁡ and sinh⁡ of the distance, which you'll meet in C10.

Worked example

A cable with a = 100 m hangs between towers 200 m apart. What is its sag, and how long is it?

Show the solution
  1. Sag. sag=a(cosh⁡L2a−1)=100(cosh⁡1−1)=100×0.543=54.3m
  2. Length. length=2asinh⁡L2a=200sinh⁡1=200×1.1752=235.0m 35 m more than the span.
  3. Compare with real lines. A cable this slack sags a lot; real power lines run with a in the hundreds or thousands of meters.

Answer the cable sags 54.3 m and is 235.0 m long.

Worked example

A tight line with a = 500 m spans 300 m. Compare its sag with the parabola's estimate L2/8a.

Show the solution
  1. Exact sag. sag=500(cosh⁡0.3−1)=500×0.04534=22.67m
  2. Parabola's estimate. L28a=30028×500=22.5m
  3. Compare. They differ by 0.8%. The parabola comes from the first terms of cosh⁡u≈1+u2/2, so it's excellent when L/2a is small, which is why sag tables for tight lines use it.

Answer the exact sag is 22.67 m and the parabola gives 22.5 m, 0.8% less.

Worked example

A differential pair with a 1 mA tail sees a 10 mV differential input (VT = 25.85 mV). How much of the current does it steer? What input steers 90%?

Show the solution
  1. Fraction steered. ΔII=tanh⁡1051.7=tanh⁡0.193=0.191 so 19.1% of the tail current shifts to one side.
  2. Check. That's almost exactly 0.193, since tanh⁡u≈u for small u.
  3. Input for 90%. vd=2VTtanh−1⁡0.9=51.7×1.472=76.1mV
  4. Full switching. Past about 100 mV the pair is fully switched, which is how a comparator decides.

Answer a 10 mV input steers 19.1% of the tail current, and 76.1 mV steers 90%.

Check

What is cosh⁡1?

Check

What is the slope of cosh⁡(2x) at x = 0.5?

Check

A cable with a = 300 m hangs across a 150 m span. What is its sag?

Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.

Check

A differential pair with a 1 mA tail current gets 50 mV of differential input (VT = 25.85 mV). How much current, ΔI, does it steer?

Write units the way you normally would: 1.5 mA, 1500 µA and 0.0015 A are the same answer.

Check

What is sinh−1⁡1?

Check

A power line has a = 200 m across a 200 m span.

(a)

What is its exact sag?

Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.

(b)

How long is the cable?

(c)

What is the slope of the cable where it meets the tower?

Check

Derive the identity and a derivative from the definitions.

Step 1

Square cosh⁡x and sinh⁡x from their definitions and subtract: what is cosh2⁡x−sinh2⁡x?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a tight power line hang almost exactly like a parabola, while a slack one doesn't?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.