A8 · Lesson 21 · Repeated roots
The fastest settle without overshoot
A meter needle, a car's suspension, a scope probe's compensation: each wants to settle as quickly as possible without overshooting. Too little damping and it rings; too much and it creeps. The boundary between the two is critical damping, where the characteristic equation's two roots merge into one. The exponential trick then gives only one solution, , and the second one turns out to be something new: .
- The solid curve is a critically damped response, , starting at 1 with zero slope. The dashed curves are its two pieces, and .
- The second piece rises and falls. Where does it peak?
- Change . Everything scales in time, and nothing ever overshoots zero.
Predict
For , the characteristic equation is . Besides , what is the second solution?
. Check it: gives and , and . A repeated root always brings a factor of , the same pattern you'll see whenever a system is driven exactly at its own natural rate.
Name it
Repeated roots
If has a double root, (which happens when ), the two independent solutions are
and the general solution is . Matching and gives and .
Where comes from (reduction of order). Try . Substituting, the terms in and cancel because is a double root, leaving : .
Critical damping in circuits
In damping-ratio form, has a double root at , . For a series RLC circuit (), that means
Released from rest, a critically damped system settles to within 2% in about , the fastest of any response that never crosses zero. With a little less damping () it settles sooner still, at the price of a small overshoot; many designs accept that trade.
Worked example
Solve with , .
Show the solution
- Double root. , so
- Fit the start. and give so .
Answer .
Worked example
A series RLC has = 10 mH and = 1 µF. What damps it critically, and how fast does it settle?
Show the solution
- Critical resistance.
- Natural frequency.
- Settling time. It settles to 2% in about
Answer 200 Ω damps it critically, and it settles to 2% in about 0.58 ms.
Worked example
A critically damped system has s⁻¹. How long does its step response take to get within 2% of the final value?
Show the solution
- Write the error. The step response is , so with the error is
- Solve for 2%. Set it to 0.02 and solve numerically (Newton's method converges in a few steps):
- Convert to time.
- Compare first order. A first-order system with the same time constant would need time constants; the critically damped one needs more because it starts out flat.
Answer it gets within 2% after 0.583 ms.
Check
What resistance damps a series RLC with = 10 mH and = 0.1 µF critically?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A critically damped system with = 1 starts at 1 with zero slope. What is ?
Check
For a double root = −2, with and . What is ?
Check
At what time does reach its peak?
Check
For which does have a repeated root?
Check
A system is critically damped. You add a little more resistance. What happens?
Check
A critically damped system starts at with = 1.
(a)
When does peak?
(b)
What is the peak value?
Check
Check that solves .
Step 1
What is ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is ?
Explain why
Why is critical damping the fastest response that never overshoots?
With less damping than critical, the roots are complex and the response oscillates, so it crosses zero and overshoots. With more, the roots are real and distinct, and the one closer to zero decays slowly, stretching the tail. Critical damping is exactly the boundary: the two roots meet at , as far from zero as real roots can get together, so the response decays as fast as possible while still having no oscillation to cause an overshoot.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.