B1 · Lesson 44 · Vibration isolation

Driving an oscillator through its base: isolators, seismometers and MEMS sensors

Lesson 43 drove an oscillator by pushing on its mass. Often the shaking comes from below instead: a pump shakes the floor, a road shakes a car, the ground shakes a building. The same spring-mass-damper then becomes either a shield or a sensor. Mounted on soft springs, sensitive equipment barely moves while the floor vibrates. Turned around, a mass on a stiff spring inside a chip moves relative to its frame in proportion to acceleration: that's every accelerometer in a phone, a car's airbag sensor and a drone's flight controller.

  • The curve is the transmissibility: how much of the base's vibration reaches the mass, against the ratio r of the driving frequency to the natural frequency.
  • Below r = √2 the springs amplify the vibration, enormously near r = 1. Above √2 they reduce it, and the more so the higher r.
  • Lower the damping: the resonance peak grows, but isolation at high r gets better. Isolators trade one against the other.

Predict

Equipment sits on springs with a natural frequency of 10 Hz. The floor vibrates at 10 Hz. What happens?

Name it

Base excitation

A mass on a spring k and damper c whose base moves as y=Ysin⁡ωt responds with amplitude TY, where, with r=ωωn and damping ratio ζ,

T=1+(2ζr)2(1−r2)2+(2ζr)2.

T = 1 at r = 0 and at r=2, peaks near 12ζ at r = 1, and falls like 1r2 (for light damping) at high r.

Isolators

To isolate a disturbance at frequency f, choose fn≤f/3 or so. A spring loaded by its mass sags by δ=gωn2, so a low natural frequency means a soft spring with a large static deflection: 5 Hz needs about 1 cm, 1 Hz about 25 cm. That's why serious isolation tables use air springs.

Seismometers and accelerometers

The motion of the mass relative to its base, z, tells about the base:

  • Far above resonance (r ≫ 1), the mass stays still and z equals the base displacement: a seismometer.
  • Far below resonance (r ≪ 1), z≈−aωn2, proportional to the base's acceleration: an accelerometer. Its sensitivity is 1ωn2, so a higher resonance gives more bandwidth but less motion per g, the central trade-off in accelerometer design. Damping near ζ = 0.7 keeps the response flat almost to resonance.

Worked example

A pump runs at 1500 rpm on isolators with a natural frequency of 5 Hz and ζ = 0.05. What fraction of its vibration reaches the floor, and how much do the isolators sag?

Show the solution
  1. Frequency ratio. 1500 rpm is 25 Hz, so r=5.
  2. Transmissibility. T=1+0.25242+0.25=0.047 so 4.7% gets through. (The same T applies whether the floor shakes the machine or the machine shakes the floor.)
  3. Static sag. δ=gωn2=9.8(2π×5)2=9.9mm
  4. Starting up. When the pump starts up, it passes through 5 Hz on the way, briefly resonating, which is why isolators include some damping.

Answer 4.7% of the vibration reaches the floor, and the isolators sag 9.9 mm.

Worked example

A MEMS accelerometer's proof mass resonates at 5 kHz. How far does it move per g of acceleration? And with a 1 kHz resonance?

Show the solution
  1. At 5 kHz. z=aωn2=9.8(2π×5000)2=9.9×10−9m about 10 nm per g.
  2. At 1 kHz. 9.8(2π×1000)2=0.25µm per g, 25 times more.
  3. The trade. Capacitive electrodes resolve motions far below a nanometer, so even the stiff design works; but halving the resonance quadruples the signal, so low-noise accelerometers accept less bandwidth.

Answer about 10 nm per g at 5 kHz, and 0.25 µm per g at 1 kHz.

Worked example

With ζ = 0.05, how much does a base vibration grow at exact resonance?

Show the solution
  1. Transmissibility at r=1. T=1+(2×0.05)20+(2×0.05)2=1.010.1=10.05
  2. What it means. A tenfold amplification is why equipment must never run at its mount's natural frequency, and why rotating machinery passes through such speeds quickly or adds damping.
  3. More damping. With ζ = 0.5 the peak would be only about 1.5, at the cost of poorer isolation at high r.

Answer the vibration grows by a factor of 10.05 at resonance.

Check

What is the transmissibility at frequency ratio r = 3 with ζ = 0.05?

Check

An isolator should have a natural frequency of 5 Hz. How much does it sag under its load?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

Check

An accelerometer's proof mass resonates at 5 kHz. How far does it move per g?

Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.

Check

Springs with a natural frequency of 10 Hz carry a machine. Above what disturbing frequency do they start to isolate?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A proof mass of 1 × 10⁻⁶ kg resonates at 2 kHz.

(a)

What is its spring's stiffness?

Write units the way you normally would: 1.5 N/m, 1500 mN/m and 0.0015 kN/m are the same answer.

(b)

How far does it move per g?

Check

A seismometer is built to measure ground displacement directly. How should its natural frequency compare with the vibrations it records?

Check

Far below resonance, the proof mass of an accelerometer follows its frame except for a small lag z.

Step 1

With spring force mωn2z supplying the mass's acceleration a (write ωn as w), what is z?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why do vibration isolators only work above 2 times their natural frequency?

Practice