title: Vibration isolation and accelerometers
heading: Driving an oscillator through its base: isolators, seismometers and MEMS sensors
eyebrow: B1 · Lesson 44 · Vibration isolation
xp: 40
---

::: hook
Lesson 43 drove an oscillator by pushing on its mass. Often the shaking comes from below instead: a pump shakes the floor, a road shakes a car, the ground shakes a building. The same spring-mass-damper then becomes either a shield or a sensor. Mounted on soft springs, sensitive equipment barely moves while the floor vibrates. Turned around, a mass on a stiff spring inside a chip moves relative to its frame in proportion to acceleration: that's every accelerometer in a phone, a car's airbag sensor and a drone's flight controller.
:::

::: play
- The curve is the **transmissibility**: how much of the base's vibration reaches the mass, against the ratio r of the driving frequency to the natural frequency.
- Below r = √2 the springs amplify the vibration, enormously near r = 1. Above √2 they reduce it, and the more so the higher r.
- Lower the damping: the resonance peak grows, but isolation at high r gets better. Isolators trade one against the other.
:::

```sim plot
view: graph
x: r = 0.1..10 log
y: T = 0.01..30 log
slider: z = 0.01..0.5 step 0.01 = 0.05
plot: sqrt((1 + (2*z*r)^2)/((1 - r^2)^2 + (2*z*r)^2)) | label: transmissibility | samples: 600
plot: 1 | dashed
readout: transmissibility at five times the natural frequency = sqrt((1 + (10*z)^2)/(576 + (10*z)^2)) | digits: 3
```

::: predict
## Equipment sits on springs with a natural frequency of 10 Hz. The floor vibrates at 10 Hz. What happens?

- [ ] The springs block the vibration
- [x] The springs make it far worse: the equipment resonates
- [ ] Nothing changes
- [ ] The vibration is halved

::: reveal
It resonates: at r = 1 the transmissibility is about $\frac{1}{2\zeta}$, 10 times for light damping. Isolation only starts above $r = \sqrt2$, so isolators are made soft enough that their natural frequency sits well below the disturbing frequency, usually by a factor of three or more.
:::
:::

::: nameit
## Base excitation

A mass on a spring k and damper c whose base moves as $y = Y\sin\omega t$ responds with amplitude $TY$, where, with $r = \frac{\omega}{\omega_n}$ and damping ratio ζ,

$$T = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}}.$$

T = 1 at r = 0 and at $r = \sqrt2$, peaks near $\frac{1}{2\zeta}$ at r = 1, and falls like $\frac{1}{r^2}$ (for light damping) at high r.

## Isolators

To isolate a disturbance at frequency f, choose $f_n \le f/3$ or so. A spring loaded by its mass sags by $\delta = \frac{g}{\omega_n^2}$, so a low natural frequency means a soft spring with a large static deflection: 5 Hz needs about 1 cm, 1 Hz about 25 cm. That's why serious isolation tables use air springs.

## Seismometers and accelerometers

The motion of the mass relative to its base, z, tells about the base:

- **Far above resonance** (r ≫ 1), the mass stays still and z equals the base displacement: a **seismometer**.
- **Far below resonance** (r ≪ 1), $z \approx -\frac{a}{\omega_n^2}$, proportional to the base's acceleration: an **accelerometer**. Its sensitivity is $\frac{1}{\omega_n^2}$, so a higher resonance gives more bandwidth but less motion per g, the central trade-off in accelerometer design. Damping near ζ = 0.7 keeps the response flat almost to resonance.
:::

::: example
## A pump runs at 1500 rpm on isolators with a natural frequency of 5 Hz and ζ = 0.05. What fraction of its vibration reaches the floor, and how much do the isolators sag?

::: solution
1. **Frequency ratio.** 1500 rpm is 25 Hz, so $r = 5$.
2. **Transmissibility.**
   $$\begin{aligned} T &= \sqrt{\frac{1 + 0.25}{24^2 + 0.25}} \\ &= 0.047 \end{aligned}$$
   so 4.7% gets through. (The same $T$ applies whether the floor shakes the machine or the machine shakes the floor.)
3. **Static sag.**
   $$\begin{aligned} \delta &= \frac{g}{\omega_n^2} \\ &= \frac{9.8}{(2\pi \times 5)^2} \\ &= 9.9\ \text{mm} \end{aligned}$$
4. **Starting up.** When the pump starts up, it passes through 5 Hz on the way, briefly resonating, which is why isolators include some damping.

**Answer:** 4.7% of the vibration reaches the floor, and the isolators sag 9.9 mm.
:::
:::

::: example
## A MEMS accelerometer's proof mass resonates at 5 kHz. How far does it move per g of acceleration? And with a 1 kHz resonance?

::: solution
1. **At 5 kHz.**
   $$\begin{aligned} z &= \frac{a}{\omega_n^2} \\ &= \frac{9.8}{(2\pi \times 5000)^2} \\ &= 9.9 \times 10^{-9}\ \text{m} \end{aligned}$$
   about 10 nm per g.
2. **At 1 kHz.**
   $$\frac{9.8}{(2\pi \times 1000)^2} = 0.25\ \text{µm}$$
   per g, 25 times more.
3. **The trade.** Capacitive electrodes resolve motions far below a nanometer, so even the stiff design works; but halving the resonance quadruples the signal, so low-noise accelerometers accept less bandwidth.

**Answer:** about 10 nm per g at 5 kHz, and 0.25 µm per g at 1 kHz.
:::
:::

::: example
## With ζ = 0.05, how much does a base vibration grow at exact resonance?

::: solution
1. **Transmissibility at $r = 1$.**
   $$\begin{aligned} T &= \sqrt{\frac{1 + (2 \times 0.05)^2}{0 + (2 \times 0.05)^2}} \\ &= \frac{\sqrt{1.01}}{0.1} \\ &= 10.05 \end{aligned}$$
2. **What it means.** A tenfold amplification is why equipment must never run at its mount's natural frequency, and why rotating machinery passes through such speeds quickly or adds damping.
3. **More damping.** With ζ = 0.5 the peak would be only about 1.5, at the cost of poorer isolation at high $r$.

**Answer:** the vibration grows by a factor of 10.05 at resonance.
:::
:::

::: check
given: r = 2 | 3 | 5; z = 0.05 | 0.2
answer: sqrt((1 + (2*z*r)^2)/((1 - r^2)^2 + (2*z*r)^2))
tolerance: 0.5%

## What is the transmissibility at frequency ratio r = {r} with ζ = {z}?

::: right
Right. Below 1, so the mount isolates.
:::

::: misses
- [1/(r^2 - 1)] That's the undamped value; include the damping terms.
- [any] $\sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}}$.
:::
:::

::: check
given: f = 2 | 5 | 10
answer: 9.8/(2*pi*f)^2*1000
unit: mm
tolerance: 0.5%

## An isolator should have a natural frequency of {f} Hz. How much does it sag under its load?

::: right
Right. $\delta = \frac{g}{\omega_n^2}$: softer mounts sag more.
:::

::: misses
- [9.8/f^2*1000] Use $\omega_n = 2\pi f$.
- [any] Static deflection $g/\omega_n^2$.
:::
:::

::: check
given: f = 1 | 5 | 20
answer: 9.8/(2*pi*f*1000)^2*1e9
unit: nm
tolerance: 0.5%

## An accelerometer's proof mass resonates at {f} kHz. How far does it move per g?

::: right
Right. $\frac{g}{\omega_n^2}$: sensitivity falls as the square of the resonance.
:::

::: misses
- [9.8/(2*pi*f*1000)*1e9] Divide by $\omega_n^2$.
- [any] $z = a/\omega_n^2$.
:::
:::

::: check
given: f = 3 | 10 | 25
answer: sqrt(2)*f
unit: Hz
tolerance: 0.5%

## Springs with a natural frequency of {f} Hz carry a machine. Above what disturbing frequency do they start to isolate?

::: right
Right. $\sqrt2f_n$, where the transmissibility crosses 1, whatever the damping.
:::

::: misses
- [f] At resonance they amplify.
- [any] T = 1 at $r = \sqrt2$.
:::
:::

::: check
kind: parts
given: m = 0.000001 | 0.00001; f = 2 | 10

## A proof mass of {m} kg resonates at {f} kHz.

::: part
answer: m*(2*pi*f*1000)^2
unit: N/m
tolerance: 0.5%

### What is its spring's stiffness?

::: misses
- [any] $k = m\omega_n^2$.
:::
:::

::: part
answer: 9.8/(2*pi*f*1000)^2*1e9
unit: nm
tolerance: 0.5%

### How far does it move per g?

::: misses
- [any] $g/\omega_n^2$, independent of the mass.
:::
:::
:::

::: check
kind: choice

## A seismometer is built to measure ground displacement directly. How should its natural frequency compare with the vibrations it records?

- [x] Well below them, so the mass stays nearly still while the frame moves
- [ ] Well above them, like an accelerometer
- [ ] Equal, for the largest response
- [ ] It doesn't matter

::: right
Right. Far above resonance the mass can't follow, so its motion relative to the frame equals the ground's displacement.
:::

::: misses
- [2] Then it measures acceleration, not displacement.
- [3] At resonance the response depends sharply on frequency and damping.
- [4] Which quantity it measures depends on that ratio.
:::
:::

::: check
kind: derivation
vars: a = 1..100, w = 100..100000

## Far below resonance, the proof mass of an accelerometer follows its frame except for a small lag z.

::: step
answer: a/w^2

### With spring force $m\omega_n^2z$ supplying the mass's acceleration a (write $\omega_n$ as w), what is z?
:::

::: step
answer: 1/w^2

### What is the sensitivity, z per unit acceleration?
:::

::: right
Right. A tenfold higher resonance gives a hundredfold smaller signal.
:::
:::

::: explain
## Why do vibration isolators only work above $\sqrt2$ times their natural frequency?

::: model
The springs pass the base's motion to the mass, and the mass's inertia resists it. At low frequency the spring is stiff compared with the inertia, so the mass simply follows the base. Near the natural frequency the forces from the spring and the inertia nearly cancel, so a small base motion builds up a large response. Well above it, the inertia dominates: the mass can't accelerate fast enough to follow, so it moves less than the base. The crossover where the mass moves exactly as much as the base falls at $\sqrt2$ times the natural frequency for any damping, and only above it does the mount protect anything.
:::
:::

::: practice

::: check
given: r = 4 | 8; z = 0.02 | 0.1
answer: sqrt((1 + (2*z*r)^2)/((1 - r^2)^2 + (2*z*r)^2))
tolerance: 0.5%

## Transmissibility at r = {r}, ζ = {z}?

::: misses
- [any] The base-excitation formula.
:::
:::

::: check
given: f = 0.2 | 0.5 | 1 | 2 | 3 | 5
answer: 9.8/(2*pi*f*1000)^2*1e9
unit: nm
tolerance: 0.5%

## Accelerometer motion per g at {f} kHz?

::: misses
- [any] $g/\omega_n^2$.
:::
:::
:::