B1046 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B10 · Lesson 46 · Quantum limits on measurement and amplification

Half a photon of noise that no amplifier can avoid

A radio astronomer cools her receiver to a few kelvin to cut its noise. A quantum-computing lab reads its qubits through amplifiers at 20 mK. An optical link's erbium amplifier has a noise figure no better than 3 dB, however well it's built. Each runs into the same wall: an amplifier that boosts both quadratures of a signal equally must add at least half a photon of noise, a consequence of lesson 3's uncertainty principle applied to a field (lesson 8's coherent states). At microwave frequencies that's a fraction of a kelvin; at optical frequencies it's thousands of kelvin, which is why optical and radio receivers are built so differently.

  • The curve is the quantum limit on a phase-insensitive amplifier's noise temperature, hf/2k, against frequency in GHz, with the noise temperature of a good cryogenic transistor amplifier for comparison.
  • At a few GHz the limit is a tenth of a kelvin, well below what transistors reach; by a few hundred GHz it rises past them, and at optical frequencies it's thousands of kelvin.

Predict

An ideal, noiseless amplifier is impossible for a phase-insensitive amplifier. At 5 GHz, roughly how much noise temperature must it add at the very least?

Name it

A mode's noise, in photons

A single mode of the field at frequency f, like a harmonic oscillator (lesson 7), holds on average

n¯=1ehf/kT−1

thermal photons, plus a zero-point half photon that's always there. When kT≫hf, n¯≈kT/hf and the noise is the classical kTB; when kT≪hf, thermal photons vanish and only the zero-point remains. At 5 GHz the crossover, hf/k, is 0.24 K: a qubit at 20 mK sees almost no thermal photons, while one at 4 K sees about 16.

The amplifier limit

A phase-insensitive amplifier, one that amplifies both quadratures of the field with the same power gain G, must add noise. Referred to its input, the added noise is at least half a photon per mode in the high-gain limit, a noise temperature

TN≥hf2k

The reason: if it added nothing, its output would be a copy of the input field, amplified, whose two quadratures could then be measured simultaneously with less uncertainty than the input allows. Phase-sensitive amplifiers, which amplify one quadrature and squeeze the other, escape the limit for that one quadrature.

In practice

Frequencyhf/2kWhat reaches it
5 GHz0.12 KJosephson parametric amplifiers, near the limit; transistor amplifiers at 4 K reach about 2 K
1 THz24 K
193 THz (1550 nm)4640 KErbium amplifiers: noise figure 3 dB at the limit

For optical amplifiers the limit appears as a noise figure of 3 dB: a quantum-limited amplifier halves the signal-to-noise ratio of a coherent signal, whose own shot noise is that half photon.

Worked example

A superconducting qubit's readout runs at 6 GHz. What is the quantum limit on its amplifier's noise temperature? If a quantum-limited parametric amplifier with 20 dB of gain feeds a 3 K transistor amplifier, what's the system noise temperature?

Show the solution
  1. Quantum limit. TQ=hf2k=6.626×10−34×6×1092×1.381×10−23K=0.144K
  2. System noise, by Friis's formula. The second stage's 3 K is divided by the first stage's gain of 100: Tsys=0.144+3/100=0.174K
  3. Without the parametric amplifier. The system would sit at 3 K, seventeen times noisier: that's why single-shot qubit readout depends on near-quantum-limited first stages.

Answer the quantum limit is 0.144 K, and the system noise temperature is 0.174 K.

Worked example

How many thermal photons occupy a 5 GHz mode at 20 mK, and at 4 K?

Show the solution
  1. Photon energy over kT at 20 mK. hf/kT=0.24/0.02=12.0
  2. Photons at 20 mK. n¯=1/(e12−1)=6.2×10−6 essentially none.
  3. At 4 K. hf/kT=0.060 and n¯=16.2, close to the classical kT/hf=16.7.
  4. What it means for a qubit. A qubit at 4 K would be scrambled by thermal photons continually; at 20 mK it starts in its ground state with near certainty, which is why dilution refrigerators exist.

Answer 6.2×10−6 thermal photons at 20 mK, and 16.2 at 4 K.

Worked example

Why can't an erbium-doped fiber amplifier have a noise figure below 3 dB at high gain?

Show the solution
  1. The signal's own noise. A coherent optical signal carries shot noise equivalent to half a photon per mode.
  2. The amplifier's noise. A phase-insensitive amplifier must add at least another half photon, referred to its input.
  3. The noise figure. The output's signal-to-noise ratio is therefore at most half the input's: a noise figure of 10log10⁡2=3.01dB
  4. Real amplifiers. Real EDFAs reach 3.5 to 5 dB. The way around it is a phase-sensitive amplifier, which amplifies one quadrature noiselessly, a technique still mostly in the lab.

Answer the amplifier must add at least as much noise as the signal already carries, halving the signal-to-noise ratio, so the noise figure is at least 3.01 dB.

Check

What is the quantum-limited noise temperature, hf/2k, of a phase-insensitive amplifier at 5 GHz?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

On average, how many thermal photons occupy a 6 GHz mode at 0.02 K?

Check

A quantum-limited amplifier at 5 GHz with 15 dB of gain feeds a second amplifier whose noise temperature is 5 K.

(a)

What noise temperature does the first stage add?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

(b)

What is the cascade's noise temperature?

Check

For a mode at f = 10 GHz, compute n¯(T) for T = np.logspace(-3, 3, 601) K. Set n to the array, Tc to the temperature where n¯ first exceeds 1, and ratio to n¯ at the highest temperature divided by the classical kT/hf there.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Show that n¯=1/(ex−1), with x=hf/kT, approaches the classical kT/hf=1/x when x is small.

Step 1

Expand ex−1 to second order in x.

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Check

Why must a phase-insensitive amplifier add noise?

Explain why

Microwave receivers for quantum computing approach the quantum limit, while optical amplifiers sit right on it. Why is the same half-photon limit easy to ignore at radio frequencies but impossible to ignore in optics?

Practice

Keep practicing

6 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.