title: Quantum limits on measurement and amplification
heading: Half a photon of noise that no amplifier can avoid
eyebrow: B10 · Lesson 46 · Quantum limits on measurement and amplification
xp: 40
---

::: hook
A radio astronomer cools her receiver to a few kelvin to cut its noise. A quantum-computing lab reads its qubits through amplifiers at 20 mK. An optical link's erbium amplifier has a noise figure no better than 3 dB, however well it's built. Each runs into the same wall: an amplifier that boosts both quadratures of a signal equally must add at least half a photon of noise, a consequence of lesson 3's uncertainty principle applied to a field (lesson 8's coherent states). At microwave frequencies that's a fraction of a kelvin; at optical frequencies it's thousands of kelvin, which is why optical and radio receivers are built so differently.
:::

::: play
- The curve is the quantum limit on a phase-insensitive amplifier's noise temperature, $hf/2k$, against frequency in GHz, with the noise temperature of a good cryogenic transistor amplifier for comparison.
- At a few GHz the limit is a tenth of a kelvin, well below what transistors reach; by a few hundred GHz it rises past them, and at optical frequencies it's thousands of kelvin.
:::

```sim plot
view: graph
x: f = 1..1000000 log
y: kelvin = 0.01..100000 log
plot: 6.626e-34*f*1e9/(2*1.381e-23) | label: quantum limit, hf/2k
plot: 2 + 0*f | dashed | label: a good 4 K transistor amplifier, about 2 K
```

::: predict
## An ideal, noiseless amplifier is impossible for a phase-insensitive amplifier. At 5 GHz, roughly how much noise temperature must it add at the very least?

- [x] About 0.12 K
- [ ] About 4 K
- [ ] About 300 K
- [ ] Zero, in principle

::: reveal
About 0.12 K, which is $hf/2k$ at 5 GHz: half a photon's energy expressed as a temperature. An amplifier that multiplies both quadratures of the field by the same gain would otherwise shrink the uncertainty of the field it measures below what the uncertainty principle allows, so it must add noise to compensate. Tiny at microwave frequencies, the same half photon is about 4600 K at 1550 nm.
:::
:::

::: nameit
## A mode's noise, in photons

A single mode of the field at frequency $f$, like a harmonic oscillator (lesson 7), holds on average

$$\bar n = \frac{1}{e^{hf/kT} - 1}$$

thermal photons, plus a zero-point half photon that's always there. When $kT \gg hf$, $\bar n \approx kT/hf$ and the noise is the classical $kTB$; when $kT \ll hf$, thermal photons vanish and only the zero-point remains. At 5 GHz the crossover, $hf/k$, is 0.24 K: a qubit at 20 mK sees almost no thermal photons, while one at 4 K sees about 16.

## The amplifier limit

A **phase-insensitive** amplifier, one that amplifies both quadratures of the field with the same power gain $G$, must add noise. Referred to its input, the added noise is at least half a photon per mode in the high-gain limit, a noise temperature

$$T_{N} \ge \frac{hf}{2k}$$

The reason: if it added nothing, its output would be a copy of the input field, amplified, whose two quadratures could then be measured simultaneously with less uncertainty than the input allows. **Phase-sensitive** amplifiers, which amplify one quadrature and squeeze the other, escape the limit for that one quadrature.

## In practice

| Frequency | $hf/2k$ | What reaches it |
|---|---|---|
| 5 GHz | 0.12 K | Josephson parametric amplifiers, near the limit; transistor amplifiers at 4 K reach about 2 K |
| 1 THz | 24 K | |
| 193 THz (1550 nm) | 4640 K | Erbium amplifiers: noise figure 3 dB at the limit |

For optical amplifiers the limit appears as a **noise figure of 3 dB**: a quantum-limited amplifier halves the signal-to-noise ratio of a coherent signal, whose own shot noise is that half photon.
:::

::: example
## A superconducting qubit's readout runs at 6 GHz. What is the quantum limit on its amplifier's noise temperature? If a quantum-limited parametric amplifier with 20 dB of gain feeds a 3 K transistor amplifier, what's the system noise temperature?

::: solution
1. **Quantum limit.**
   $$\begin{aligned} T_Q &= \frac{hf}{2k} \\ &= \frac{6.626 \times 10^{-34} \times 6 \times 10^9}{2 \times 1.381 \times 10^{-23}}\ \text{K} \\ &= 0.144\ \text{K} \end{aligned}$$
2. **System noise, by Friis's formula.** The second stage's 3 K is divided by the first stage's gain of 100:
   $$\begin{aligned} T_\text{sys} &= 0.144 + 3/100 \\ &= 0.174\ \text{K} \end{aligned}$$
3. **Without the parametric amplifier.** The system would sit at 3 K, seventeen times noisier: that's why single-shot qubit readout depends on near-quantum-limited first stages.

**Answer:** the quantum limit is 0.144 K, and the system noise temperature is 0.174 K.
:::
:::

::: example
## How many thermal photons occupy a 5 GHz mode at 20 mK, and at 4 K?

::: solution
1. **Photon energy over kT at 20 mK.**
   $$\begin{aligned} hf/kT &= 0.24/0.02 \\ &= 12.0 \end{aligned}$$
2. **Photons at 20 mK.**
   $$\begin{aligned} \bar n &= 1/(e^{12} - 1) \\ &= 6.2 \times 10^{-6} \end{aligned}$$
   essentially none.
3. **At 4 K.** $hf/kT = 0.060$ and $\bar n = 16.2$, close to the classical $kT/hf = 16.7$.
4. **What it means for a qubit.** A qubit at 4 K would be scrambled by thermal photons continually; at 20 mK it starts in its ground state with near certainty, which is why dilution refrigerators exist.

**Answer:** $6.2 \times 10^{-6}$ thermal photons at 20 mK, and 16.2 at 4 K.
:::
:::

::: example
## Why can't an erbium-doped fiber amplifier have a noise figure below 3 dB at high gain?

::: solution
1. **The signal's own noise.** A coherent optical signal carries shot noise equivalent to half a photon per mode.
2. **The amplifier's noise.** A phase-insensitive amplifier must add at least another half photon, referred to its input.
3. **The noise figure.** The output's signal-to-noise ratio is therefore at most half the input's: a noise figure of
   $$10\log_{10}2 = 3.01\ \text{dB}$$
4. **Real amplifiers.** Real EDFAs reach 3.5 to 5 dB. The way around it is a phase-sensitive amplifier, which amplifies one quadrature noiselessly, a technique still mostly in the lab.

**Answer:** the amplifier must add at least as much noise as the signal already carries, halving the signal-to-noise ratio, so the noise figure is at least 3.01 dB.
:::
:::

::: check
given: f = 1 | 5 | 10 | 300
answer: 6.62607e-34*f*1e9/(2*1.380649e-23)
unit: K
tolerance: 0.5%

## What is the quantum-limited noise temperature, $hf/2k$, of a phase-insensitive amplifier at {f} GHz?

::: right
Right. $hf/2k$ = {answer}.
:::

::: misses
- [6.62607e-34*f*1e9/1.380649e-23] That's $hf/k$, a whole photon. The limit is half a photon.
- [6.62607e-34*f/(2*1.380649e-23)] Convert GHz to Hz.
- [any] Not yet. Compute $hf/(2k)$ in SI units.
:::
:::

::: check
given: f = 5 | 6 | 8; T = 0.02 | 0.05 | 0.1 | 4
answer: 1/(exp(6.62607e-34*f*1e9/(1.380649e-23*T)) - 1)
tolerance: 1%

## On average, how many thermal photons occupy a {f} GHz mode at {T} K?

::: right
Right. $\bar n = 1/(e^{hf/kT} - 1)$ = {answer}.
:::

::: misses
- [1.380649e-23*T/(6.62607e-34*f*1e9)] That's the classical $kT/hf$, valid only when $kT \gg hf$.
- [any] Not yet. Use the Bose-Einstein occupation $1/(e^{hf/kT} - 1)$.
:::
:::

::: check
kind: parts
given: f = 5 | 7; G = 15 | 20; T2 = 2 | 5

## A quantum-limited amplifier at {f} GHz with {G} dB of gain feeds a second amplifier whose noise temperature is {T2} K.

::: part
answer: 6.62607e-34*f*1e9/(2*1.380649e-23)
unit: K
tolerance: 0.5%

### What noise temperature does the first stage add?

::: misses
- [0] A phase-insensitive amplifier can't be noiseless: it adds at least $hf/2k$.
- [any] Not yet. Use $hf/2k$.
:::
:::

::: part
answer: 6.62607e-34*f*1e9/(2*1.380649e-23) + T2/10^(G/10)
unit: K
tolerance: 0.5%

### What is the cascade's noise temperature?

::: misses
- [6.62607e-34*f*1e9/(2*1.380649e-23) + T2] Divide the second stage's noise by the first stage's power gain (Friis).
- [6.62607e-34*f*1e9/(2*1.380649e-23) + T2/G] Convert the gain from dB to a ratio first.
- [any] Not yet. $T = T_1 + T_2/G_1$ with $G_1$ as a ratio.
:::
:::

::: right
Right. The first stage's gain hides the second stage's noise, so it pays to put the quietest amplifier first, even one with modest gain.
:::
:::

::: check
kind: python
given: f = 5 | 10 | 100 | 1000

## For a mode at `f` = {f} GHz, compute $\bar n(T)$ for `T = np.logspace(-3, 3, 601)` K. Set `n` to the array, `Tc` to the temperature where $\bar n$ first exceeds 1, and `ratio` to $\bar n$ at the highest temperature divided by the classical $kT/hf$ there.

```python starter
import numpy as np
T = np.logspace(-3, 3, 601)
n = T
Tc = 1
ratio = 1
print(Tc, ratio)
```

```python solution
import numpy as np
h, k = 6.62607015e-34, 1.380649e-23
T = np.logspace(-3, 3, 601)
x = h * f * 1e9 / (k * T)
n = 1 / np.expm1(x)
Tc = T[np.argmax(n > 1)]
ratio = n[-1] / (k * T[-1] / (h * f * 1e9))
print(Tc, ratio)
```

```python tests
import numpy as np
h, k = 6.62607015e-34, 1.380649e-23
TT = np.logspace(-3, 3, 601); nn = 1 / np.expm1(h * f * 1e9 / (k * TT))
assert np.allclose(n, nn, rtol=1e-12), "n is 1/(exp(hf/kT) - 1); np.expm1 avoids losing digits when hf/kT is small."
assert abs(Tc - TT[np.argmax(nn > 1)]) < 1e-12, "Tc is the first temperature on the grid where n exceeds 1."
assert abs(Tc - h * f * 1e9 / (k * np.log(2))) / Tc < 0.03, "n = 1 when hf/kT = ln 2, so Tc ≈ hf/(k ln 2)."
assert abs(ratio - nn[-1] / (k * TT[-1] / (h * f * 1e9))) < 1e-9 and ratio < 1, "At high temperature n approaches kT/hf from below."
```

::: right
Right. The mode holds about one photon at $T = hf/(k\ln 2)$; below that it empties exponentially, above it the classical $kT/hf$ takes over. Where that crossover falls decides whether a system is "quantum" at a given temperature.
:::
:::

::: check
kind: derivation
vars: x = 0.01..0.2

## Show that $\bar n = 1/(e^{x} - 1)$, with $x = hf/kT$, approaches the classical $kT/hf = 1/x$ when $x$ is small.

::: step
answer: x + x^2/2

### Expand $e^x - 1$ to second order in $x$.
:::

::: step
answer: 1/x - 1/2

### Then $1/(e^x - 1) \approx \frac{1}{x}\left(1 - \frac{x}{2}\right)$ to first order. What is it?
:::

::: right
Right. $\bar n \approx kT/hf - \frac12$: the classical value, less half a photon. Adding back the zero-point half photon gives exactly $kT/hf$, which is why the classical $kTB$ noise formula already includes it.
:::
:::

::: check
kind: choice

## Why must a phase-insensitive amplifier add noise?

- [x] If it amplified both quadratures without adding noise, measuring its output would beat the uncertainty principle for the input field
- [ ] Because every real component has resistance
- [ ] Because amplifiers get warm
- [ ] It doesn't; better engineering could make it noiseless

::: right
Right. The input's two quadratures can't both be known precisely; a noiseless copy, amplified, would let you measure both with relative precision as good as you like. The added half photon is exactly what restores the limit. It's a law, not an engineering shortfall.
:::

::: misses
- [2] Resistive loss adds thermal noise, but even a lossless, perfect amplifier must add the half photon.
- [3] Cooling removes thermal noise, but the quantum limit remains at absolute zero.
- [4] It's required by quantum mechanics; only phase-sensitive amplifiers, working on one quadrature, avoid it.
:::
:::

::: explain
## Microwave receivers for quantum computing approach the quantum limit, while optical amplifiers sit right on it. Why is the same half-photon limit easy to ignore at radio frequencies but impossible to ignore in optics?

::: model
The limit is half a photon, whose energy is proportional to frequency: $hf/2k$ is 0.12 K at 5 GHz but about 4600 K at 193 THz. At radio frequencies everything else is far noisier: room-temperature thermal noise is 300 K, and even cryogenic transistor amplifiers add a few kelvin, so the quantum limit hides beneath them. At optical frequencies thermal photons vanish at any practical temperature, so the zero-point half photon is the only noise left, and it dominates: an optical amplifier can't do better than a 3 dB noise figure, and photon counting replaces amplification for the faintest signals.
:::
:::

::: practice

::: check
given: f = 1 | 2 | 5 | 10 | 20 | 100
answer: 6.62607e-34*f*1e9/1.380649e-23
unit: K
tolerance: 0.5%

## What is $hf/k$, the temperature equivalent of one photon, at {f} GHz?

::: misses
- [6.62607e-34*f*1e9/(2*1.380649e-23)] That's half a photon.
- [any] $hf/k$ in kelvin.
:::
:::

::: check
given: G = 10 | 15 | 20 | 25 | 30 | 40
answer: 10*log(2)
unit: dB
tolerance: 0.05

## What is the minimum noise figure of a high-gain, phase-insensitive optical amplifier ({G} dB of gain)?

::: misses
- [0] A phase-insensitive amplifier must add noise.
- [any] Halving the SNR is $10\log_{10}2$ dB.
:::
:::
:::