title: Bolometers and thermal detectors
heading: Detecting light by the heat it leaves behind, from thermal-camera pixels to cryogenic X-ray calorimeters
eyebrow: B11 · Lesson 45 · Thermal detectors
xp: 40
---

::: hook
A thermal camera's sensor is an array of tiny plates, each hanging on two thin legs above a silicon readout chip. Infrared light warms a plate by a few millikelvin, and the plate's resistance changes. Nothing about it is quantum: it's lesson 44's thermal circuit, a heat capacity and a thermal conductance, made as small as lithography allows. The same idea, cooled to a tenth of a kelvin, measures single X-ray photons' energies to a few electronvolts. How sensitive and how fast such a detector can be is set by thermal physics, and so is the noise that limits it.
:::

::: play
- The curve is a thermal detector's temperature rise for each nanowatt absorbed, against how fast the light is chopped.
- Below the corner $f = \frac{1}{2\pi\tau}$ the response is flat at $\frac{1}{G}$; above it, the heat capacity can't keep up and the response falls as 1/f.
- Shrink G (thinner legs) and the response rises, but τ = C/G grows and the corner moves down. Shrinking C is the only way to gain both.
:::

```sim plot
view: graph
x: f = 0.1..10000 Hz log
y: r = 0.0001..100 log
slider: G = 10..1000 = 100 log
slider: C = 0.1..10 = 1 log
plot: 1000/G/sqrt(1 + (2*pi*f*C/G)^2) | label: temperature rise per nW absorbed, mK | samples: 300
marker: f = G/(2*pi*C) | label: corner
readout: time constant C/G, ms = 1000*C/G | digits: 3
readout: DC rise per nW, mK = 1000/G | digits: 3
```

::: predict
## A thermal camera pixel is made with half the leg conductance G and the same heat capacity. What happens?

- [ ] It gets more sensitive and faster
- [x] It gets twice as sensitive but twice as slow
- [ ] Nothing changes, because the light is the same
- [ ] It gets less sensitive

::: reveal
Twice as sensitive and twice as slow. The steady temperature rise is $\Delta T = \frac{P}{G}$, so halving G doubles it; but the time constant $\tau = \frac{C}{G}$ doubles too. Camera pixels are designed for a time constant of about 10 ms, short enough for 30 frames a second, which fixes G for a given C. Making the plates thinner and lighter lowers C, and that's what improves both.
:::
:::

::: nameit
## The thermal detector

An absorber with heat capacity C hangs from a bath at $T_0$ by a weak thermal link of conductance G (W/K). Absorbing power P warms it by

$$\Delta T = \frac{P}{G}\quad\text{(steady)}, \qquad \frac{\Delta T}{P} = \frac{1}{G\sqrt{1 + (\omega\tau)^2}}\quad\text{at frequency }\omega,$$

with time constant $\tau = \frac{C}{G}$: the RC circuit of lesson 44, with heat for charge.

## Reading the temperature

A **bolometer** reads ΔT as a resistance change. With temperature coefficient $\alpha = \frac{1}{R}\frac{dR}{dT}$ (about −2%/K for vanadium oxide, which most camera pixels use), a bias current I turns it into a voltage, giving a responsivity

$$S = \frac{|\alpha|IR}{G}\ \text{V/W}$$

below the corner. Thermopiles read ΔT with thermocouples (lesson 28), and pyroelectric detectors with a crystal whose polarization changes with temperature.

## Noise

The link carries heat in random packets, so even in the dark the absorber's temperature fluctuates, with $\langle\delta T^2\rangle = \frac{kT^2}{C}$ (the canonical ensemble's energy spread divided by $C^2$). Seen as noise on the input power, this **phonon noise** has a noise-equivalent power

$$\text{NEP} = \sqrt{4kT^2G}\ \text{W}/\sqrt{\text{Hz}}:$$

the absorbed power, in a 1 Hz band, that would give a signal equal to the noise. The resistor's Johnson noise adds $\frac{\sqrt{4kTR}}{S}$, and in practice 1/f noise of the material often adds more.

## Going cold

At 0.1 K, $T^2$ in the noise falls by about ten million and heat capacities shrink, so cryogenic detectors are far more sensitive. A **transition-edge sensor** sits on a superconductor's transition, where α is in the hundreds, and as a calorimeter it measures each absorbed photon's energy as a pulse of height $\frac{E}{C}$, with fluctuations of order $\sqrt{kT^2C}$.
:::

::: example
## A microbolometer pixel has C = 1 nJ/K and G = 100 nW/K, and its vanadium oxide (α = −2%/K, R = 100 kΩ) is biased at 20 µA. Find its time constant, its temperature rise per nanowatt and its responsivity.

::: solution
1. **Time constant.**
   $$\begin{aligned} \tau &= \frac{C}{G} \\ &= \frac{10^{-9}}{10^{-7}} \\ &= 10\ \text{ms} \end{aligned}$$
   so its corner is at 16 Hz.
2. **Temperature rise per nanowatt.**
   $$\frac{10^{-9}}{10^{-7}} = 10\ \text{mK}$$
3. **Voltage change per kelvin.** The resistance changes by 2% of 100 kΩ per kelvin, so at 20 µA the voltage changes by
   $$0.02 \times 2\ \text{V} = 40\ \text{mV}$$
   per kelvin.
4. **Responsivity.**
   $$\begin{aligned} S &= \frac{|\alpha|IR}{G} \\ &= \frac{0.04}{10^{-7}} \\ &= 4 \times 10^5\ \text{V/W} \end{aligned}$$
   or 0.4 mV per nanowatt.
5. **Bias heating.** The bias heats the pixel too ($I^2R$ = 40 µW), which is why cameras pulse the bias briefly during readout.

**Answer:** the time constant is 10 ms, the pixel warms 10 mK per nanowatt, and its responsivity is 4 × 10⁵ V/W (0.4 mV per nanowatt).
:::
:::

::: example
## For the same pixel at 300 K, how large are its temperature fluctuations, its phonon-noise NEP, and its Johnson-noise NEP?

::: solution
1. **Temperature fluctuations.** Spread over the detector's whole bandwidth,
   $$\begin{aligned} \delta T_{rms} &= \sqrt{\frac{kT^2}{C}} \\ &= \sqrt{\frac{1.38 \times 10^{-23} \times 9 \times 10^4}{10^{-9}}} \\ &= 35\ \mu\text{K} \end{aligned}$$
2. **Phonon-noise NEP.**
   $$\sqrt{4kT^2G} = 7.0 \times 10^{-13}\ \text{W}/\sqrt{\text{Hz}}$$
3. **Johnson-noise NEP.** The resistor's Johnson noise, $\sqrt{4kTR}$ = 40.7 nV/√Hz, divided by S gives $1.0 \times 10^{-13}$ W/√Hz, seven times smaller.
4. **Combined.** In quadrature they're $7.1 \times 10^{-13}$ W/√Hz, so here the thermal link itself sets the floor: no amount of electronics can beat it.

**Answer:** the temperature fluctuates by 35 µK RMS, the phonon-noise NEP is 7.0 × 10⁻¹³ W/√Hz and the Johnson-noise NEP is 1.0 × 10⁻¹³ W/√Hz.
:::
:::

::: example
## A transition-edge sensor at 0.1 K has C = 1 pJ/K. How much does a 6 keV X-ray photon warm it, and how large are its intrinsic energy fluctuations?

::: solution
1. **Photon energy.**
   $$\begin{aligned} E &= 6000 \times 1.602 \times 10^{-19} \\ &= 9.6 \times 10^{-16}\ \text{J} \end{aligned}$$
2. **Temperature rise.**
   $$\frac{E}{C} = 0.96\ \text{mK}$$
3. **Temperature fluctuations.**
   $$\sqrt{kT^2/C} = 3.7 \times 10^{-7}\ \text{K}$$
4. **Energy fluctuations.** That's 0.04% of the photon's energy:
   $$\begin{aligned} \sqrt{kT^2C} &= 3.7 \times 10^{-19}\ \text{J} \\ &= 2.3\ \text{eV} \end{aligned}$$
5. **In practice.** Real sensors reach about 2 eV resolution at 6 keV, enough to separate X-ray lines that semiconductor detectors blur together. At 300 K the same calculation gives about 7 keV, which is why such calorimeters only work cold.

**Answer:** the photon warms the sensor by 0.96 mK, and its intrinsic energy fluctuations are about 2.3 eV.
:::
:::

::: check
kind: parts
given: C = 0.5 | 2; G = 50 | 200

## A thermal detector has C = {C} nJ/K and G = {G} nW/K.

::: part
answer: C/G*1000
unit: ms
tolerance: 0.5%

### What's its time constant?

::: misses
- [G/C*1000] τ = C/G, like RC.
- [any] $\tau = \frac{C}{G}$.
:::
:::

::: part
answer: 1000/G
unit: mK
tolerance: 0.5%

### How much does 1 nW warm it, in steady state?

::: misses
- [any] $\Delta T = \frac{P}{G}$.
:::
:::

::: part
answer: 1/sqrt(1 + (2*pi*30*C/G)^2)
tolerance: 0.5%

### At 30 Hz chopping, what fraction of that steady response remains?

::: misses
- [any] $\frac{1}{\sqrt{1 + (\omega\tau)^2}}$.
:::
:::
:::

::: check
given: a = 1 | 2 | 3; I = 10 | 30; R = 50 | 100
answer: a/100*I*1e-6*R*1e3/1e-7
unit: V/W
tolerance: 0.5%

## A bolometer with |α| = {a}%/K and R = {R} kΩ is biased at {I} µA, with G = 100 nW/K. What's its responsivity?

::: right
Right. $S = \frac{|\alpha|IR}{G}$.
:::

::: misses
- [a*I*1e-6*R*1e3/1e-7] α is a percentage per kelvin; use it as a fraction.
- [any] $\frac{|\alpha|IR}{G}$.
:::
:::

::: check
given: T = 0.1 | 4 | 300; C = 1 | 1000
answer: sqrt(1.380649e-23*T^2/(C*1e-12))*1e6
unit: µK
tolerance: 0.5%

## An absorber with heat capacity {C} pJ/K sits in equilibrium at {T} K. How large are its RMS temperature fluctuations?

::: right
Right. $\sqrt{kT^2/C}$.
:::

::: misses
- [sqrt(1.380649e-23*T/(C*1e-12))*1e6] It's $kT^2$, from the energy variance $kT^2C$.
- [any] $\delta T_{rms} = \sqrt{kT^2/C}$.
:::
:::

::: check
given: T = 0.1 | 300; G = 1 | 100
answer: sqrt(4*1.380649e-23*T^2*G*1e-9)*1e15
unit: fW/√Hz
tolerance: 0.5%

## A thermal link of G = {G} nW/K sits at {T} K. What's its phonon-noise NEP, in fW/√Hz?

::: right
Right. $\sqrt{4kT^2G}$.
:::

::: misses
- [sqrt(4*1.380649e-23*T*G*1e-9)*1e15] Phonon noise scales as T, not $\sqrt T$: it's $\sqrt{4kT^2G}$.
- [any] $\text{NEP} = \sqrt{4kT^2G}$.
:::
:::

::: check
kind: choice

## Why do thermal camera pixels hang on long, thin legs over the chip?

- [ ] To keep them flat
- [ ] To carry more current
- [x] To make the thermal conductance G small, so absorbed light warms them measurably
- [ ] To make them faster

::: right
Right. A tiny G turns nanowatts into millikelvins. The cost is a longer time constant, C/G, so the plates are made as light as possible.
:::

::: misses
- [1] The legs are for thermal isolation; flatness comes from the process.
- [2] Thin legs carry less current, which is fine for a few microamps of bias.
- [4] A smaller G makes the pixel slower, not faster.
:::
:::

::: check
given: T = 0.05 | 0.1; C = 0.5 | 2
answer: sqrt(1.380649e-23*T^2*C*1e-12)/1.602176634e-19
unit: eV
tolerance: 0.5%

## A calorimeter at {T} K has C = {C} pJ/K. How large are its intrinsic energy fluctuations?

::: right
Right. $\sqrt{kT^2C}$, the canonical spread of its energy.
:::

::: misses
- [sqrt(1.380649e-23*T^2/(C*1e-12))/1.602176634e-19] That's the temperature spread; multiply by C for energy.
- [any] $\delta E = \sqrt{kT^2C}$.
:::
:::

::: check
given: E = 1 | 6; C = 0.5 | 2
answer: E*1000*1.602176634e-19/(C*1e-12)*1000
unit: mK
tolerance: 0.5%

## A calorimeter with C = {C} pJ/K absorbs a {E} keV photon. How much does it warm?

::: right
Right. $\Delta T = \frac{E}{C}$.
:::

::: misses
- [any] Convert keV to joules, then divide by C.
:::
:::

::: check
kind: derivation
vars: C = 0.000000001..0.000001, G = 0.00000001..0.000001, w = 0.1..10000

## A thermal detector with heat capacity C (J/K) and link conductance G (W/K), illuminated at angular frequency w.

::: step
answer: C/G

### What's its time constant?
:::

::: step
answer: 1/(G*sqrt(1 + (w*C/G)^2))

### What's its temperature rise per watt absorbed?
:::

::: step
answer: atan(w*C/G)

### By what phase, in radians, does the temperature lag the light?
:::

::: right
Right. It's a one-pole low-pass, like an RC circuit with G as conductance and C as capacitance.
:::
:::

::: explain
## Why does making a thermal detector's heat capacity smaller improve it, when its steady response doesn't depend on C at all?

::: model
The steady response, $\Delta T = P/G$, depends only on the link, so a smaller G gives more signal. But the detector must also respond quickly, and its time constant is $\tau = C/G$. For a required speed, such as 30 frames a second, τ is fixed, so G can be made only as small as C allows: $G = C/\tau$. A lighter absorber lets G shrink in proportion, raising the response without slowing the detector. The phonon noise, $\sqrt{4kT^2G}$, also falls as G falls, so a smaller C improves both signal and noise. That's why pixels are made of the thinnest membranes that can still absorb the light.
:::
:::

::: practice

::: check
given: C = 1 | 5; G = 20 | 300
answer: C/G*1000
unit: ms
tolerance: 0.5%

## Time constant for C = {C} nJ/K, G = {G} nW/K?

::: misses
- [any] $\tau = \frac{C}{G}$.
:::
:::

::: check
given: T = 0.1 | 300; G = 5 | 50
answer: sqrt(4*1.380649e-23*T^2*G*1e-9)*1e15
unit: fW/√Hz
tolerance: 0.5%

## Phonon NEP in fW/√Hz at {T} K, G = {G} nW/K?

::: misses
- [any] $\sqrt{4kT^2G}$.
:::
:::
:::