title: Cryogenics and low-temperature electronics
heading: Getting cold, staying cold, and keeping room-temperature noise out
eyebrow: B11 · Lesson 49 · Cryogenics and low-temperature electronics
xp: 50
---

::: hook
Superconducting qubits run at about 15 mK, superconducting detectors at a few hundred millikelvin, radio-astronomy amplifiers at 4 K, and infrared imagers at 77 K. Cold electronics are quieter (lessons 12 and 46), but every wire that reaches the cold stage carries heat down from room temperature and, if it's a signal line, room-temperature noise too. Cryogenic engineering is the thermal physics of this course put to work: latent heats that set how fast a dewar boils off, Carnot limits that make every milliwatt at the coldest stage precious, and attenuators placed at each stage so that thermal photons from 300 K are absorbed and re-emitted at a colder, quieter temperature.
:::

::: play
- A 5 GHz control line runs from 300 K to a qubit at 15 mK through attenuators at 4 K, 100 mK and 15 mK. The curve is the average number of thermal photons reaching the qubit, against the attenuation at the last stage.
- Each attenuator passes a fraction 1/A of the noise arriving from above and adds its own stage's thermal noise times (1 − 1/A): it acts as a partial blackbody at its own temperature.
- With 20 dB at each stage the qubit sees about 0.004 thermal photons. Take out the 4 K attenuator and room-temperature noise floods through; that's why every stage gets its share.
:::
:::

```sim plot
view: graph
x: c = 0..40 dB
y: n = 0.00001..100 log
slider: a = 0..30 step 1 = 20 dB
slider: b = 0..30 step 1 = 20 dB
plot: ((1249.71/10^(a/10) + 16.1744*(1 - 1/10^(a/10)))/10^(b/10) + 0.0998127*(1 - 1/10^(b/10)))/10^(c/10) + 0.000000112836*(1 - 1/10^(c/10)) | label: thermal photons at the qubit
readout: after the 4 K stage = 1249.71/10^(a/10) + 16.1744*(1 - 1/10^(a/10))
readout: after the 100 mK stage = (1249.71/10^(a/10) + 16.1744*(1 - 1/10^(a/10)))/10^(b/10) + 0.0998127*(1 - 1/10^(b/10))
```

::: predict
## A liquid-helium dewar has a 1 W heat leak. How fast does it boil off?

- [ ] About 1 mL per hour
- [ ] About 0.02 L per hour
- [x] About 1.4 L per hour
- [ ] About 40 L per hour

::: reveal
Helium's latent heat is tiny: 20.8 J/g, and with a density of 0.125 g/cm³ that's only 2.6 kJ per liter. One watt for an hour is 3.6 kJ, so 1.4 L/h. Liquid nitrogen, at 161 kJ/L, would lose only 0.022 L/h. That's why helium dewars are shielded by nitrogen-cooled or vacuum-insulated layers, and why modern systems use closed-cycle cryocoolers instead.
:::
:::

::: nameit
## Cryogens

| | boils at | latent heat |
|---|---|---|
| nitrogen | 77 K | 161 kJ/L |
| helium-4 | 4.2 K | 2.6 kJ/L |

Pumping on a liquid lowers its vapor pressure and, by Clausius–Clapeyron, its temperature: helium-4 reaches about 1.2 K, helium-3 about 0.3 K.

## Below 1 K: dilution refrigerators

A mixture of helium-3 and helium-4 separates into two phases below about 0.8 K. Driving helium-3 atoms across the phase boundary absorbs heat, like evaporation, continuously and without a limiting vapor pressure. The cooling power falls as $T^2$: a fridge with 100 µW at 100 mK has about 2 µW at 15 mK.

## Heat leaks

- **Conduction** down a wire of cross section A and length L: $\dot Q = \frac AL\int_{T_c}^{T_h}\kappa(T)\,dT$. Thin, long wires of poor conductors (phosphor bronze, stainless steel, superconducting NbTi) keep it small, and every wire is thermally anchored at each stage.
- **Radiation**, $\varepsilon\sigma A(T_h^4 - T_c^4)$, is blocked by nested shields at intermediate temperatures.

## Noise on signal lines

A matched attenuator with loss A at physical temperature T passes 1/A of the incoming noise and adds its own:

$$n_{out} = \frac{n_{in}}A + n(T)\left(1 - \frac1A\right), \qquad n(T) = \frac{1}{e^{hf/kT} - 1}$$

In temperature terms, a lossy element at T has noise temperature $T(A - 1)$ referred to its input. That's why receivers put their LNA before any lossy cable, and why qubit lines are attenuated in steps.

## Cold amplifiers

Transistor amplifiers (HEMTs) at 4 K reach noise temperatures of 2 to 5 K at microwave frequencies. Quantum-limited parametric amplifiers, operating at millikelvin, approach the quantum limit of half a photon of added noise, $hf/2k$ = 0.12 K at 5 GHz.
:::

::: example
## Follow room-temperature noise at 5 GHz through 20 dB attenuators at 4 K, 100 mK and 15 mK.

::: solution
1. **At 300 K.** n = 1250 photons per mode.
2. **After the 4 K attenuator.**
   $$\begin{aligned} n &= 1250/100 + 16.2 \times 0.99 \\ &= 28.5 \end{aligned}$$
3. **After 100 mK.**
   $$\begin{aligned} n &= 0.285 + 0.0998 \times 0.99 \\ &= 0.384 \end{aligned}$$
4. **After 15 mK.**
   $$\begin{aligned} n &= 0.00384 + 1.1 \times 10^{-7} \\ &\approx 0.0038 \end{aligned}$$
5. **What sets the result.** Each stage's own emission dominates what it sends on, so the attenuation at the coldest stage sets the result, as long as the warmer stages have cut the flood from above.

**Answer:** the 1250 photons per mode from room temperature become 28.5 after 4 K, 0.384 after 100 mK and 0.0038 after 15 mK.
:::
:::

::: example
## A cable at 300 K has 3 dB of loss before an LNA. What noise temperature does it add, referred to its input?

::: solution
1. **Noise added by the cable.** A = 2, so
   $$T(A - 1) = 300\ \text{K}$$
2. **With an amplifier behind it.** A 30 K amplifier behind it becomes a system of
   $$300 + 2 \times 30 = 360\ \text{K}$$
3. **The better order.** Put the LNA at the antenna and the same cable adds only 300/G of noise behind the amplifier's gain.

**Answer:** the cable adds 300 K, referred to its input.
:::
:::

::: example
## A 4 K stage with 0.1 m² of surface and an effective emissivity of 0.05 faces a 300 K vacuum can. How much heat does radiation bring in? How much if a 50 K shield surrounds it instead?

::: solution
1. **Radiation from the 300 K can.**
   $$\begin{aligned} P &= \varepsilon\sigma A(T_h^4 - T_c^4) \\ &= 0.05 \times 5.67 \times 10^{-8} \times 0.1 \\ &\quad \times 300^4 \\ &= 2.30\ \text{W} \end{aligned}$$
   That would boil about 3 L of liquid helium an hour.
2. **With a 50 K shield.** The 4 K stage sees $50^4$ instead of $300^4$, 1296 times less: 1.8 mW.
3. **Where the heat goes instead.** The shield itself takes the 2.3 W, but at 50 K it can be cooled by a cryocooler's first stage or by the helium's cold exhaust gas, where removing heat costs far less work.

**Answer:** radiation brings in 2.30 W from the 300 K can, and 1.8 mW with a 50 K shield in between.
:::
:::

::: check
given: Q = 0.1 | 0.5 | 2; L = 2.6 | 161
answer: Q*3600/(L*1000)
unit: L/h
tolerance: 0.5%

## A cryostat bath has a {Q} W heat load. How fast does it boil off a cryogen whose latent heat is {L} kJ/L?

::: right
Right. $\frac{Q \times 3600\text{ s}}{L}$ = {answer} L/h.
:::

::: misses
- [Q/(L*1000)] Convert seconds to hours: the rate per hour is 3600 times the rate per second.
- [any] Not yet. Heat per hour divided by heat per liter.
:::
:::

::: check
given: n = 28.5 | 0.4 | 3; A = 10 | 20 | 30; m = 16.2 | 0.5 | 2
answer: n/10^(A/10) + m*(1 - 1/10^(A/10))
tolerance: 0.5%

## {n} thermal photons per mode arrive at a {A} dB attenuator whose own temperature corresponds to {m} photons per mode. How many leave?

::: right
Right. $\frac{n_{in}}A + n(T)\left(1 - \frac1A\right)$ = {answer}.
:::

::: misses
- [n/10^(A/10)] Add the attenuator's own thermal emission.
- [any] Not yet. Convert dB to a ratio: A = $10^{dB/10}$.
:::
:::

::: check
given: P = 50 | 200 | 1000; T = 10 | 20 | 50
answer: P*(T/100)^2
unit: µW
tolerance: 0.5%

## A dilution refrigerator has {P} µW of cooling power at 100 mK. About how much does it have at {T} mK?

::: right
Right. Cooling power ∝ $T^2$: {answer} µW.
:::

::: misses
- [P*(T/100)] It falls as the square of the temperature.
- [any] Not yet. Scale by $(T/T_0)^2$.
:::
:::

::: check
given: T = 4 | 77 | 300; L = 0.5 | 1 | 3
answer: T*(10^(L/10) - 1)
unit: K
tolerance: 0.5%

## A cable at {T} K has {L} dB of loss. What noise temperature does it add, referred to its input?

::: right
Right. $T(A - 1)$ = {answer} K.
:::

::: misses
- [T*(1 - 1/10^(L/10))] That's referred to the output; at the input, divide by the gain 1/A.
- [any] Not yet. A = $10^{L/10}$.
:::
:::

::: check
given: A = 0.01 | 0.1; L = 0.2 | 1; I = 200 | 1500
answer: A*1e-6/L*I*1000
unit: mW
tolerance: 0.5%

## A wire of cross section {A} mm² and length {L} m runs from 300 K to 4 K. Its conductivity integral over that range is {I} W/m. How much heat does it conduct?

::: right
Right. $\frac AL\int\kappa\,dT$ = {answer} mW.
:::

::: misses
- [A/L*I] Convert mm² to m².
- [any] Not yet. Q = (A/L) × integral.
:::
:::

::: check
given: f = 4 | 6 | 8
answer: 0.047992*f/2
unit: K
tolerance: 0.5%

## What's the quantum limit on an amplifier's added noise, hf/2k, at {f} GHz?

::: right
Right. {answer} K.
:::

::: misses
- [0.047992*f] Half a photon: hf/2k.
- [any] Not yet. h/k = 0.048 K per GHz.
:::
:::

::: check
kind: parts
given: A = 0.05 | 0.2; e = 0.02 | 0.1; T = 40 | 77

## A 4 K stage has {A} m² of surface with effective emissivity {e}.

::: part
answer: e*5.670374e-8*A*(300^4 - 4^4)
unit: W
tolerance: 0.5%

### How much heat does it receive by radiation from a 300 K wall?

::: misses
- [any] $\varepsilon\sigma A(T_h^4 - T_c^4)$.
:::
:::

::: part
answer: e*5.670374e-8*A*(T^4 - 4^4)*1000
unit: mW
tolerance: 0.5%

### How much from a {T} K shield instead?

::: misses
- [any] Use the shield's temperature.
:::
:::
:::

::: check
kind: derivation
vars: k = 1..1000, A = 0.00000001..0.00001, L = 0.1..2, d = 1..300

## A wire of average conductivity k (W/(m·K)), cross section A (m²) and length L (m) spans a temperature difference d.

::: step
answer: L/(k*A)

### What's its thermal resistance?
:::

::: step
answer: k*A*d/L

### How much heat does it conduct?
:::

::: right
Right. Cryostat wiring uses thin, long, low-conductivity wire such as stainless steel or phosphor bronze, and is heat-sunk at each stage.
:::
:::

::: explain
## Why are qubit drive lines attenuated in steps at several temperatures, rather than all at once at the coldest stage?

::: model
An attenuator absorbs most of the noise coming from above, but it also emits its own thermal noise at its physical temperature, and the power it absorbs turns into heat at that stage. If all the attenuation sat at the coldest stage, it would have to absorb the full room-temperature noise and signal power, heating a stage whose cooling power is only microwatts. Putting most of the attenuation at 4 K, where cooling power is a watt or so, removes nearly all the room-temperature noise cheaply; the next stage removes the 4 K noise; and the last stage only has to cut the residual noise from 100 mK down to the qubit's level. Each stage's own emission is small because each is cold, so the qubit ends up seeing almost no thermal photons.
:::
:::

::: practice

::: check
given: Q = 0.05 | 5; L = 2.6 | 161
answer: Q*3600/(L*1000)
unit: L/h
tolerance: 0.5%

## Boil-off for {Q} W, latent heat {L} kJ/L?

::: misses
- [any] Q × 3600 / L.
:::
:::

::: check
given: n = 1000 | 10; A = 6 | 30; m = 20 | 0.05
answer: n/10^(A/10) + m*(1 - 1/10^(A/10))
tolerance: 0.5%

## Photons out: {n} in, {A} dB, stage at {m} photons?

::: misses
- [any] $\frac{n}{A} + m(1 - \frac1A)$.
:::
:::

::: check
given: T = 20 | 290; L = 0.3 | 6
answer: T*(10^(L/10) - 1)
unit: K
tolerance: 0.5%

## Noise temperature of {L} dB loss at {T} K?

::: misses
- [any] $T(A - 1)$.
:::
:::
:::