B1127 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B11 · Lesson 27 · Heat engines, refrigerators and the Carnot limit

The price of moving heat, and of erasing a bit

A refrigerator moves heat from cold to hot, against its natural direction, and pays for it in work. The second law sets the minimum price, and it rises steeply as the cold side gets colder: keeping a superconducting chip at 4 K means removing every watt it dissipates with at least 70 W of work at room temperature, and real cryocoolers need ten times that. The same accounting limits power plants, heat pumps and, in the end, computation itself: erasing one bit of information must dump at least kT ln 2 of heat.

  • The curve is the minimum work needed to pump one watt of heat out of a cold space at temperature Tc and reject it at Th, on log scales: Th−TcTc.
  • At 77 K (liquid nitrogen) it's about 3 W per watt; at 4 K (liquid helium, superconducting electronics) about 70; at the 20 mK of a qubit's mixing chamber, 15,000.
  • Real machines reach only a fraction of the Carnot limit, a smaller fraction the colder they go. That's why cryogenic computing is budgeted in microwatts at the coldest stage.

Predict

A computer erases a bit of memory at room temperature. What's the least heat the erasure must release?

Name it

Engines

An engine takes heat Qh from a reservoir at Th, does work W, and rejects Qc=Qh−W at Tc. The entropy it removes from the hot reservoir, Qh/Th, must at least be delivered to the cold one, Qc/Tc, so

η=WQh≤1−TcTh

the Carnot efficiency, reached only by a reversible engine. Any shortfall shows up as entropy generated: Sgen=QcTc−QhTh≥0.

Refrigerators and heat pumps

Run backward: work W pumps Qc out of the cold side and delivers Qh=Qc+W to the hot side.

COPref=QcW≤TcTh−Tc,COPhp=QhW≤ThTh−Tc

The minimum work per unit of heat removed, Th−TcTc, diverges as Tc → 0. Real cryocoolers: about 25–30% of Carnot at 77 K, 1–2% at 4 K, far less at millikelvin.

Landauer's principle

Logically irreversible operations, like erasing or overwriting a bit, reduce the entropy of the information-bearing degrees of freedom by k ln 2 per bit, so they must dissipate at least

Emin=kTln⁡2

per bit. Reversible logic could in principle avoid it, at the cost of keeping every intermediate result.

Worked example

A superconducting circuit dissipates 1 W at 4.2 K. What's the minimum room-temperature power to remove it?

Show the solution
  1. Carnot limit for a refrigerator. W=QcTh−TcTc=1×295.84.2=70W
  2. A real refrigerator. At a realistic 1.5% of Carnot it's about 4.7 kW.
  3. Why it matters. That's why cryogenic systems treat every milliwatt at 4 K as precious, and why wiring is chosen for low thermal conductance.

Answer at least 70 W, and about 4.7 kW in practice.

Worked example

What's the Landauer limit at room temperature, and at 4 K?

Show the solution
  1. At room temperature. kTln⁡2=2.87×10−21J
  2. At 4 K. kTln⁡2=3.8×10−23J
  3. Pumping the heat out. The heat released at 4 K must then be pumped to room temperature, at a cost of at least 2964 times as much work, so the total is kTcln⁡2×ThTc=kThln⁡2=2.9×10−21J
  4. Cooling doesn't help. The total comes back to the room-temperature value, so cooling can't beat the room-temperature limit.

Answer 2.87×10−21 J at 300 K and 3.8×10−23 J at 4 K, but pumping the heat back to room temperature brings the total back to 2.9×10−21 J.

Worked example

A house is kept at 20 °C. Compare a resistive heater with the best possible heat pump when it's 0 °C outside and when it's −10 °C. A real heat pump reaches about 40% of the Carnot limit.

Show the solution
  1. The resistive heater. It turns each joule of electricity into one joule of heat.
  2. The best heat pump at 0 °C. It moves heat in from outside, and its best coefficient of performance is COP=ThTh−Tc=293.1520=14.7
  3. The best heat pump at −10 °C. COP=293.1530=9.8
  4. A real heat pump. At 40% of that, it delivers 5.9 J of heat per joule of electricity at 0 °C and 3.9 J at −10 °C.
  5. Why cold weather costs more. Colder weather costs more twice over: the house loses heat faster, and every joule moved has to climb a larger temperature difference.

Answer the heater gives 1 J of heat per joule of electricity; the best heat pump gives 14.7 J at 0 °C and 9.8 J at −10 °C, and a real one 5.9 J and 3.9 J.

Check

What's the Carnot efficiency between 800 K and 300 K?

Check

What's the best possible coefficient of performance for a refrigerator holding 20 K, rejecting heat at 295 K?

Check

A cryocooler running at 0.3 of the Carnot limit removes 1 W at 0.02 K, rejecting at 300 K. What input power does it need?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

At 4 K, what's the minimum power to erase 1 × 10⁹ bits per second?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

An engine between 600 K and 300 K takes 100 J and has efficiency 0.3. How much entropy does it generate?

Write units the way you normally would: 1.5 J/K, 1500 mJ/K and 0.0015 kJ/K are the same answer.

Check

A heat pump moves heat from outdoors at 255 K into a house at 295 K. What's its best possible COP?

Check

An engine between 600 K and 300 K delivers 1000 W at 0.6 of the Carnot efficiency.

(a)

How much heat does it draw from the hot side?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

How much heat does it reject?

(c)

At what rate does it make entropy?

Check

Heat flows between a hot side at H and a cold side at C (kelvin).

Step 1

What's the Carnot efficiency of an engine between them?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does cooling get so much more expensive as the cold side approaches absolute zero?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.