B11 · Lesson 44 · Heat flow in electronics: thermal resistance and capacitance
Junction temperatures, heat sinks and power pulses
Every watt a transistor dissipates has to reach the air, and the junction runs as much hotter than the air as the heat's path demands. Too hot, and leakage runs away (lesson 37), the Arrhenius clock of lesson 3 eats the part's lifetime, and eventually the silicon fails. Thermal design treats heat flow exactly like current in a circuit: temperature differences are voltages, heat flow is current, each layer of silicon, solder, pad and heat sink is a thermal resistance, and each mass is a thermal capacitance. A short power pulse sees only the small capacitance of the die, so it can be far stronger than the steady power the heat sink could handle.
- A power transistor on a heat sink, modeled as two stages: the die and case (0.5 K/W, time constant 10 ms) and the heat sink (2 K/W, 30 s). A power pulse of height P and length starts at t = 0; the curve is the junction's rise above ambient, against time on a log scale.
- A 1 ms pulse heats only the die: the rise is a few kelvin even at 100 W. Lengthen the pulse past a few tens of milliseconds and the die saturates at P × 0.5 K/W; past tens of seconds the heat sink fills too.
- After the pulse ends the junction cools on the same time scales. Datasheets give exactly this as a "transient thermal impedance" curve.
Predict
A MOSFET's junction-to-ambient path is 0.5 K/W (junction to case) + 0.5 K/W (insulating pad) + 5 K/W (heat sink). It dissipates 10 W with 40 °C air. How hot is the junction?
The resistances are in series, like resistors: 6 K/W total, so the junction is 60 K above the air, at 100 °C. Most of the rise is in the heat sink, so that's where a better design pays off; halving the pad's resistance saves only 2.5 K.
Name it
Thermal resistance
Fourier's law, , makes a slab of thickness L, area A and conductivity κ a resistance
Convection from a surface of area A with coefficient h (5–25 W/(m²·K) in still air, 50–500 with a fan) is ; radiation adds roughly in parallel (lesson 11).
The thermal circuit
In steady state, resistances add in series and combine in parallel, exactly like electrical ones:
with θ the datasheet's names for junction-to-case, case-to-sink and sink-to-ambient. The largest power allowed is .
Thermal capacitance
A body of mass m and specific heat c stores heat with capacitance (J/K). A resistance feeding a capacitance has time constant τ = , so a step of power P raises the temperature as .
Transient thermal impedance
Real packages have several layers, each with its own R and C. Datasheets fit them as a sum of independent stages (a Foster network):
A pulse of power P lasting raises the junction by , far less than when is short compared with the slow stages. Linearity lets you add delayed copies of for any power waveform, the thermal version of convolution with a step response.
Worked example
A 100 W, 1 ms pulse hits a die modeled as 0.5 K/W with τ = 10 ms (the heat sink is too slow to matter). How much does the junction heat?
Show the solution
- Junction rise during the pulse.
- Compare with steady state. In steady state the same 100 W would raise it by 250 K through the whole path, so pulsed ratings can be tens of times the continuous ones.
- Long faults. The opposite case matters too: a long fault lasting seconds heats the heat sink as well.
Answer the junction heats by about 4.8 K.
Worked example
What's the conduction resistance of a silicon die 0.5 mm thick and 5 mm square (κ = 150 W/(m·K))?
Show the solution
- Conduction resistance.
- Its place in the whole path. The die itself is a small part of the path; the solder, the package base and the interface to the heat sink usually dominate θ_jc and θ_cs.
Answer the die's conduction resistance is about 0.13 K/W.
Worked example
A power part sits on a 1.6 mm FR-4 board with thermal vias under it: 0.3 mm holes plated with 25 µm of copper (κ = 385 W/(m·K)). What's one via's thermal resistance, and that of an array of 20?
Show the solution
- Copper area of one via. The copper is a tube with outer radius 0.15 mm and inner radius 0.125 mm:
- One via.
- Twenty in parallel.
- Compare with bare board. FR-4 itself conducts about 0.3 W/(m·K), so the same 0.43 mm² of board without vias would be over 10 000 K/W; the vias carry nearly all the heat.
- Doing better. Filling them with solder or copper, or adding more of them, is the cheap way to cut this resistance further.
Answer one via is 192 K/W, and an array of 20 is 9.6 K/W.
Check
What's the thermal resistance of a layer 0.5 mm thick, area 100 mm², conductivity 1 W/(m·K)?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
Check
A part dissipates 5 W with θ_jc = 1.2, θ_cs = 0.6 and θ_sa = 1.5 K/W, in 40 °C air. What's its junction temperature?
Check
A part's junction may reach 150 °C. With 12 K/W from junction to ambient and 40 °C air, how much can it dissipate continuously?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A pulse of 100 W lasts 10 ms. The die stage has R = 0.3 K/W and τ = 20 ms. How much does the junction rise?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
A 50 g heat sink with specific heat 385 J/(kg·K) sits behind 3 K/W to ambient. What's its thermal time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A surface of 20 cm² has a convection coefficient of 50 W/(m²·K). What's its convective thermal resistance?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
Check
Thermal vias of 0.3 mm drill, plated with 25 µm of copper (385 W/(m·K)), pass through a 1.6 mm board.
(a)
What's one via's thermal resistance?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
(b)
What's the resistance of 9 of them in parallel?
Check
A part with thermal resistance R (K/W) and heat capacity C (J/K) starts dissipating P (W) at t = 0.
Step 1
What's its thermal time constant?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
How much has it warmed after time t?
Step 3
How fast does it warm at the start, in K/s?
Explain why
Why can a power transistor safely handle a much larger pulse than its continuous power rating?
A transistor's continuous rating is set by the full thermal resistance from junction to ambient: the heat has to flow all the way out, and the junction settles at ambient plus power times that resistance. But each layer along the path also stores heat, and it takes a time of order RC for a layer to warm up. During a pulse much shorter than the heat sink's time constant, the heat goes mostly into raising the temperature of the die and package, which has a small capacitance but also a small resistance to fill, and the heat sink never warms appreciably. The junction's rise is the transient thermal impedance at the pulse length, which can be a few percent of the steady value, so the allowed pulse power is correspondingly larger, as long as the pulses are spaced out enough to let the average stay within the continuous limit.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.