title: "Heat flow in electronics: thermal resistance and capacitance"
heading: Junction temperatures, heat sinks and power pulses
eyebrow: "B11 · Lesson 44 · Heat flow in electronics: thermal resistance and capacitance"
xp: 50
---

::: hook
Every watt a transistor dissipates has to reach the air, and the junction runs as much hotter than the air as the heat's path demands. Too hot, and leakage runs away (lesson 37), the Arrhenius clock of lesson 3 eats the part's lifetime, and eventually the silicon fails. Thermal design treats heat flow exactly like current in a circuit: temperature differences are voltages, heat flow is current, each layer of silicon, solder, pad and heat sink is a **thermal resistance**, and each mass is a **thermal capacitance**. A short power pulse sees only the small capacitance of the die, so it can be far stronger than the steady power the heat sink could handle.
:::

::: play
- A power transistor on a heat sink, modeled as two stages: the die and case (0.5 K/W, time constant 10 ms) and the heat sink (2 K/W, 30 s). A power pulse of height P and length $t_p$ starts at t = 0; the curve is the junction's rise above ambient, against time on a log scale.
- A 1 ms pulse heats only the die: the rise is a few kelvin even at 100 W. Lengthen the pulse past a few tens of milliseconds and the die saturates at P × 0.5 K/W; past tens of seconds the heat sink fills too.
- After the pulse ends the junction cools on the same time scales. Datasheets give exactly this as a "transient thermal impedance" curve.
:::
:::

```sim plot
view: graph
x: t = 0.0001..1000 s log
y: T = 0..50 K
slider: P = 1..200 = 50 W log
slider: tp = 0.001..300 = 0.01 s log
plot: P*(0.5*(1 - exp(-t/0.01)) + 2*(1 - exp(-t/30)) - step(t - tp)*(0.5*(1 - exp(-(t - tp)/0.01)) + 2*(1 - exp(-(t - tp)/30)))) | samples: 1500 | label: junction rise above ambient, K
readout: peak rise, K = P*(0.5*(1 - exp(-tp/0.01)) + 2*(1 - exp(-tp/30)))
readout: steady rise at this power, K = P*2.5
```

::: predict
## A MOSFET's junction-to-ambient path is 0.5 K/W (junction to case) + 0.5 K/W (insulating pad) + 5 K/W (heat sink). It dissipates 10 W with 40 °C air. How hot is the junction?

- [ ] 45 °C
- [ ] 60 °C
- [x] 100 °C
- [ ] 150 °C

::: reveal
The resistances are in series, like resistors: 6 K/W total, so the junction is 60 K above the air, at 100 °C. Most of the rise is in the heat sink, so that's where a better design pays off; halving the pad's resistance saves only 2.5 K.
:::
:::

::: nameit
## Thermal resistance

Fourier's law, $q = -\kappa\nabla T$, makes a slab of thickness L, area A and conductivity κ a resistance

$$R_{th} = \frac{L}{\kappa A}\quad\text{(K/W)}$$

Convection from a surface of area A with coefficient h (5–25 W/(m²·K) in still air, 50–500 with a fan) is $\frac{1}{hA}$; radiation adds roughly $\frac{1}{h_{rad}A}$ in parallel (lesson 11).

## The thermal circuit

In steady state, resistances add in series and combine in parallel, exactly like electrical ones:

$$T_j = T_a + P(\theta_{jc} + \theta_{cs} + \theta_{sa})$$

with θ the datasheet's names for junction-to-case, case-to-sink and sink-to-ambient. The largest power allowed is $P_{max} = \frac{T_{j,max} - T_a}{\sum\theta}$.

## Thermal capacitance

A body of mass m and specific heat c stores heat with capacitance $C_{th} = mc$ (J/K). A resistance feeding a capacitance has time constant τ = $R_{th}C_{th}$, so a step of power P raises the temperature as $PR_{th}(1 - e^{-t/\tau})$.

## Transient thermal impedance

Real packages have several layers, each with its own R and C. Datasheets fit them as a sum of independent stages (a Foster network):

$$Z_{th}(t) = \sum_iR_i\left(1 - e^{-t/\tau_i}\right)$$

A pulse of power P lasting $t_p$ raises the junction by $PZ_{th}(t_p)$, far less than $PR_{th}$ when $t_p$ is short compared with the slow stages. Linearity lets you add delayed copies of $Z_{th}$ for any power waveform, the thermal version of convolution with a step response.
:::

::: example
## A 100 W, 1 ms pulse hits a die modeled as 0.5 K/W with τ = 10 ms (the heat sink is too slow to matter). How much does the junction heat?

::: solution
1. **Junction rise during the pulse.**
   $$\begin{aligned} \Delta T &= 100 \times 0.5 \times (1 - e^{-0.1}) \\ &= 4.8\ \text{K} \end{aligned}$$
2. **Compare with steady state.** In steady state the same 100 W would raise it by 250 K through the whole path, so pulsed ratings can be tens of times the continuous ones.
3. **Long faults.** The opposite case matters too: a long fault lasting seconds heats the heat sink as well.

**Answer:** the junction heats by about 4.8 K.
:::
:::

::: example
## What's the conduction resistance of a silicon die 0.5 mm thick and 5 mm square (κ = 150 W/(m·K))?

::: solution
1. **Conduction resistance.**
   $$\begin{aligned} R &= \frac{L}{\kappa A} \\ &= \frac{0.5 \times 10^{-3}}{150 \times 2.5 \times 10^{-5}} \\ &= 0.13\ \text{K/W} \end{aligned}$$
2. **Its place in the whole path.** The die itself is a small part of the path; the solder, the package base and the interface to the heat sink usually dominate θ_jc and θ_cs.

**Answer:** the die's conduction resistance is about 0.13 K/W.
:::
:::

::: example
## A power part sits on a 1.6 mm FR-4 board with thermal vias under it: 0.3 mm holes plated with 25 µm of copper (κ = 385 W/(m·K)). What's one via's thermal resistance, and that of an array of 20?

::: solution
1. **Copper area of one via.** The copper is a tube with outer radius 0.15 mm and inner radius 0.125 mm:
   $$\begin{aligned} A &= \pi(0.15^2 - 0.125^2) \\ &= 0.0216\ \text{mm}^2 \end{aligned}$$
2. **One via.**
   $$\begin{aligned} R &= \frac{L}{\kappa A} \\ &= \frac{1.6 \times 10^{-3}}{385 \times 2.16 \times 10^{-8}} \\ &= 192\ \text{K/W} \end{aligned}$$
3. **Twenty in parallel.**
   $$\frac{192}{20} = 9.6\ \text{K/W}$$
4. **Compare with bare board.** FR-4 itself conducts about 0.3 W/(m·K), so the same 0.43 mm² of board without vias would be over 10 000 K/W; the vias carry nearly all the heat.
5. **Doing better.** Filling them with solder or copper, or adding more of them, is the cheap way to cut this resistance further.

**Answer:** one via is 192 K/W, and an array of 20 is 9.6 K/W.
:::
:::

::: check
given: L = 0.1 | 0.5 | 2; k = 1 | 150 | 400; A = 10 | 25 | 100
answer: L*1e-3/(k*A*1e-6)
unit: K/W
tolerance: 0.5%

## What's the thermal resistance of a layer {L} mm thick, area {A} mm², conductivity {k} W/(m·K)?

::: right
Right. $\frac{L}{\kappa A}$ = {answer} K/W.
:::

::: misses
- [L/(k*A)] Convert to SI: mm to m and mm² to m².
- [any] Not yet. $R_{th} = L/\kappa A$.
:::
:::

::: check
given: a = 25 | 40 | 55; P = 5 | 15 | 40; j = 0.5 | 1.2; s = 0.2 | 0.6; h = 1.5 | 4
answer: a + P*(j + s + h)
unit: °C
tolerance: 0.5%

## A part dissipates {P} W with θ_jc = {j}, θ_cs = {s} and θ_sa = {h} K/W, in {a} °C air. What's its junction temperature?

::: right
Right. $T_a + P\sum\theta$ = {answer} °C.
:::

::: misses
- [P*(j + s + h)] Add the ambient temperature.
- [any] Not yet. Series thermal resistances.
:::
:::

::: check
given: j = 125 | 150 | 175; a = 40 | 70; r = 2 | 5 | 12
answer: (j - a)/r
unit: W
tolerance: 0.5%

## A part's junction may reach {j} °C. With {r} K/W from junction to ambient and {a} °C air, how much can it dissipate continuously?

::: right
Right. $\frac{T_{j,max} - T_a}{\sum\theta}$ = {answer} W.
:::

::: misses
- [j/r] Use the temperature rise allowed, not the absolute temperature.
- [any] Not yet. Invert $T_j = T_a + P\theta$.
:::
:::

::: check
given: P = 20 | 100 | 300; R = 0.3 | 0.8; t = 0.5 | 2 | 10; u = 5 | 20
answer: P*R*(1 - exp(-t/u))
unit: K
tolerance: 0.5%

## A pulse of {P} W lasts {t} ms. The die stage has R = {R} K/W and τ = {u} ms. How much does the junction rise?

::: right
Right. $PR(1 - e^{-t_p/\tau})$ = {answer} K.
:::

::: misses
- [P*R] That's the steady-state rise; a short pulse only partly charges the thermal capacitance.
- [any] Not yet. Single-stage step response.
:::
:::

::: check
given: m = 10 | 50 | 200; c = 385 | 900; R = 1 | 3
answer: m/1000*c*R
unit: s
tolerance: 0.5%

## A {m} g heat sink with specific heat {c} J/(kg·K) sits behind {R} K/W to ambient. What's its thermal time constant?

::: right
Right. τ = $R\,mc$ = {answer} s.
:::

::: misses
- [m*c*R] Convert grams to kilograms.
- [any] Not yet. $C_{th} = mc$, τ = RC.
:::
:::

::: check
given: h = 10 | 50 | 200; A = 20 | 100 | 400
answer: 1/(h*A*1e-4)
unit: K/W
tolerance: 0.5%

## A surface of {A} cm² has a convection coefficient of {h} W/(m²·K). What's its convective thermal resistance?

::: right
Right. $\frac{1}{hA}$ = {answer} K/W.
:::

::: misses
- [1/(h*A)] Convert cm² to m².
- [any] Not yet. $R = 1/hA$.
:::
:::

::: check
kind: parts
given: d = 0.3 | 0.5; n = 9 | 20 | 40

## Thermal vias of {d} mm drill, plated with 25 µm of copper (385 W/(m·K)), pass through a 1.6 mm board.

::: part
answer: 1.6e-3/(385*pi*((d/2)^2 - (d/2 - 0.025)^2)*1e-6)
unit: K/W
tolerance: 0.5%

### What's one via's thermal resistance?

::: misses
- [1.6e-3/(385*pi*(d/2)^2*1e-6)] Only the copper tube conducts well, not the whole hole.
- [any] $\frac{L}{\kappa A}$ with the plating's ring area.
:::
:::

::: part
answer: 1.6e-3/(385*pi*((d/2)^2 - (d/2 - 0.025)^2)*1e-6)/n
unit: K/W
tolerance: 0.5%

### What's the resistance of {n} of them in parallel?

::: misses
- [any] Divide by the number of vias.
:::
:::
:::

::: check
kind: derivation
vars: R = 0.1..10, C = 0.01..100, P = 1..100, t = 0.001..100

## A part with thermal resistance R (K/W) and heat capacity C (J/K) starts dissipating P (W) at t = 0.

::: step
answer: R*C

### What's its thermal time constant?
:::

::: step
answer: P*R*(1 - exp(-t/(R*C)))

### How much has it warmed after time t?
:::

::: step
answer: P/C

### How fast does it warm at the start, in K/s?
:::

::: right
Right. At first all the heat goes into C; R only matters once the part has warmed enough to push heat out.
:::
:::

::: explain
## Why can a power transistor safely handle a much larger pulse than its continuous power rating?

::: model
A transistor's continuous rating is set by the full thermal resistance from junction to ambient: the heat has to flow all the way out, and the junction settles at ambient plus power times that resistance. But each layer along the path also stores heat, and it takes a time of order RC for a layer to warm up. During a pulse much shorter than the heat sink's time constant, the heat goes mostly into raising the temperature of the die and package, which has a small capacitance but also a small resistance to fill, and the heat sink never warms appreciably. The junction's rise is the transient thermal impedance at the pulse length, which can be a few percent of the steady value, so the allowed pulse power is correspondingly larger, as long as the pulses are spaced out enough to let the average stay within the continuous limit.
:::
:::

::: practice

::: check
given: L = 0.05 | 3; k = 0.5 | 300; A = 4 | 400
answer: L*1e-3/(k*A*1e-6)
unit: K/W
tolerance: 0.5%

## R_th for {L} mm, {k} W/(m·K), {A} mm²?

::: misses
- [any] $L/\kappa A$.
:::
:::

::: check
given: a = 20 | 60; P = 2 | 60; r = 0.8 | 7
answer: a + P*r
unit: °C
tolerance: 0.5%

## Junction temperature: {a} °C, {P} W, {r} K/W?

::: misses
- [any] $T_a + P\theta$.
:::
:::

::: check
given: P = 10 | 500; R = 0.1 | 1.5; t = 0.1 | 50; u = 2 | 40
answer: P*R*(1 - exp(-t/u))
unit: K
tolerance: 0.5%

## Pulse rise: {P} W for {t} ms, R = {R} K/W, τ = {u} ms?

::: misses
- [any] $PR(1 - e^{-t/\tau})$.
:::
:::
:::