B1128 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B11 · Lesson 28 · Thermoelectric effects: Seebeck, Peltier and ZT

Turning heat into voltage, and current into cooling

Charge carriers carry heat as well as charge. Push a current through a junction of two materials and heat is absorbed on one side and released on the other: the Peltier effect, which cools the laser diodes in fiber-optic transmitters and the sensors in thermal cameras with no moving parts. Run it backward, hold the junctions at different temperatures, and a voltage appears: the Seebeck effect, which every thermocouple uses and which powers deep-space probes from the heat of decaying plutonium. One figure of merit, ZT, decides how well a material does either job, and it comes straight from transport and entropy.

  • A Peltier cooler module (Seebeck coefficient 0.051 V/K, resistance 2 Ω, thermal conductance 0.5 W/K) holds its hot side at 300 K. The curve is the heat pumped from the cold side against current, for the temperature difference you set.
  • Small currents pump in proportion to I (the Peltier term). Large currents waste power as I2R Joule heat, half of which flows back to the cold side. In between there's an optimum (readout).
  • Raise ΔT: heat leaking back through the module lowers the whole curve, until at about 69 K it can't pump anything: the module's maximum ΔT.

Predict

A type K thermocouple has a Seebeck coefficient of about 41 µV/K. Its measuring junction is in boiling water and the reference junction at 0 °C. What voltage does it produce?

Name it

Seebeck

A temperature gradient across a conductor drives carriers from hot to cold until an electric field balances them. The open-circuit voltage per kelvin is the Seebeck coefficient S: a few µV/K in metals, hundreds of µV/K in semiconductors (positive for holes, negative for electrons). A loop of two materials A and B with junctions at different temperatures produces

V=(SA−SB)ΔT

Peltier

A current I through a junction carries heat at rate ΠI on each side, with a jump at the junction of (ΠA−ΠB)I. Kelvin's relation, from the second law, links the two effects:

Π=ST

S is the entropy carried per unit charge; Π is the heat.

The thermoelectric cooler

A module with total Seebeck coefficient S, resistance R and thermal conductance K, cold side at Tc, ΔT across it:

Qc=STcI−12I2R−KΔT

Best current I=STc/R, giving Qc,max=(STc)22R−KΔT. The largest ΔT it can hold (with Qc = 0) is ΔTmax=12ZTc2, with

Z=S2RK(module),ZT=S2σTκ(material)

Figure of merit

Good thermoelectrics need a large S, high electrical conductivity σ (low Joule loss) and low thermal conductivity κ (little heat leaking back). Bismuth telluride reaches ZT ≈ 1 near room temperature. A generator's best efficiency is

ηmax=(1−TcTh)1+ZT−11+ZT+Tc/Th

with T the mean temperature: about a fifth of Carnot at ZT = 1.

Worked example

For the module in the sim, find Z, ZT at 300 K and the maximum temperature difference.

Show the solution
  1. Figure of merit. Z=0.050822×0.5=2.58×10−3K−1 so ZT = 0.77 at 300 K.
  2. Maximum temperature difference. Solve ΔT=12ZTc2 with Tc=300−ΔT, which gives Tc = 231 K and ΔT = 69 K.
  3. Compare with real modules. Commercial single-stage modules quote about 70 K; for more, stack stages.

Answer Z = 2.58 × 10⁻³ K⁻¹, ZT = 0.77 at 300 K, and the maximum temperature difference is 69 K.

Worked example

A thermoelectric generator with ZT = 1 runs between 500 K and 300 K. What's its best efficiency?

Show the solution
  1. Carnot efficiency. ηC=1−300500=0.40
  2. Best thermoelectric efficiency. ηmax=0.40×2−12+0.6=0.40×0.206=8.2%
  3. Where they're used. That's why thermoelectric generators are used where reliability matters more than efficiency: space probes, remote sensors, waste-heat recovery.

Answer the best efficiency is 8.2%.

Worked example

A thermoelectric generator module has S = 0.05 V/K and internal resistance 2 Ω. With 100 K across it, what's its open-circuit voltage, and what's the most power it can deliver?

Show the solution
  1. Open-circuit voltage. SΔT=5V
  2. Matched load. The module behaves like a 5 V source behind 2 Ω, so the most power goes into a matched 2 Ω load: Pmax=(SΔT)24R=258=3.1W at a current of 1.25 A and 2.5 V across the load.
  3. The best-efficiency load. Because the current also carries Peltier heat back from the hot side and adds Joule heat, the load that gives the best efficiency is a little larger than the matched one: RL=R1+ZT

Answer the open-circuit voltage is 5 V, and the module delivers at most 3.1 W, into a matched 2 Ω load.

Check

A thermocouple pair has relative Seebeck coefficient 52 µV/K. What voltage appears for a 50 K difference between its junctions?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

A junction with Seebeck coefficient difference 200 µV/K carries 3 A at 250 K. At what rate does it absorb Peltier heat?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

Check

A Peltier module has S = 0.04 V/K, R = 1.5 Ω and K = 0.6 W/K. With its cold side at 280 K, what's the largest temperature difference it can hold?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

The same kind of module (S = 0.04 V/K, R = 1.5 Ω, K = 0.6 W/K) runs at 2 A with its cold side at 290 K and hot side at 300 K. How much heat does it pump?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

A material has S = 150 µV/K, σ = 500 S/cm and κ = 1.5 W/(m·K). What's its ZT at 400 K?

Check

A generator with ZT = 1 runs between 450 K and 320 K. What's its best efficiency?

Check

A generator module has S = 0.02 V/K and internal resistance 1 Ω, with 150 K across it.

(a)

What's its open-circuit voltage?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What's the most power it can deliver?

(c)

What current flows then?

Check

A material with Seebeck coefficient S (V/K), conductivity s (S/m) and thermal conductivity k (W/(m·K)), at T.

Step 1

What's its power factor, in W/(m·K²)?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a good thermoelectric material need low thermal conductivity as well as a large Seebeck coefficient?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.