B11 · Lesson 28 · Thermoelectric effects: Seebeck, Peltier and ZT
Turning heat into voltage, and current into cooling
Charge carriers carry heat as well as charge. Push a current through a junction of two materials and heat is absorbed on one side and released on the other: the Peltier effect, which cools the laser diodes in fiber-optic transmitters and the sensors in thermal cameras with no moving parts. Run it backward, hold the junctions at different temperatures, and a voltage appears: the Seebeck effect, which every thermocouple uses and which powers deep-space probes from the heat of decaying plutonium. One figure of merit, ZT, decides how well a material does either job, and it comes straight from transport and entropy.
- A Peltier cooler module (Seebeck coefficient 0.051 V/K, resistance 2 Ω, thermal conductance 0.5 W/K) holds its hot side at 300 K. The curve is the heat pumped from the cold side against current, for the temperature difference you set.
- Small currents pump in proportion to I (the Peltier term). Large currents waste power as Joule heat, half of which flows back to the cold side. In between there's an optimum (readout).
- Raise ΔT: heat leaking back through the module lowers the whole curve, until at about 69 K it can't pump anything: the module's maximum ΔT.
Predict
A type K thermocouple has a Seebeck coefficient of about 41 µV/K. Its measuring junction is in boiling water and the reference junction at 0 °C. What voltage does it produce?
V = SΔT = 41 µV/K × 100 K = 4.1 mV (the standard table gives 4.096 mV). It's a small signal, which is why thermocouple amplifiers are high-gain, low-offset designs, and why the reference-junction temperature has to be measured too (cold-junction compensation).
Name it
Seebeck
A temperature gradient across a conductor drives carriers from hot to cold until an electric field balances them. The open-circuit voltage per kelvin is the Seebeck coefficient S: a few µV/K in metals, hundreds of µV/K in semiconductors (positive for holes, negative for electrons). A loop of two materials A and B with junctions at different temperatures produces
Peltier
A current I through a junction carries heat at rate ΠI on each side, with a jump at the junction of . Kelvin's relation, from the second law, links the two effects:
S is the entropy carried per unit charge; Π is the heat.
The thermoelectric cooler
A module with total Seebeck coefficient S, resistance R and thermal conductance K, cold side at , ΔT across it:
Best current , giving . The largest ΔT it can hold (with = 0) is , with
Figure of merit
Good thermoelectrics need a large S, high electrical conductivity σ (low Joule loss) and low thermal conductivity κ (little heat leaking back). Bismuth telluride reaches ZT ≈ 1 near room temperature. A generator's best efficiency is
with T the mean temperature: about a fifth of Carnot at ZT = 1.
Worked example
For the module in the sim, find Z, ZT at 300 K and the maximum temperature difference.
Show the solution
- Figure of merit. so ZT = 0.77 at 300 K.
- Maximum temperature difference. Solve with , which gives = 231 K and ΔT = 69 K.
- Compare with real modules. Commercial single-stage modules quote about 70 K; for more, stack stages.
Answer Z = 2.58 × 10⁻³ K⁻¹, ZT = 0.77 at 300 K, and the maximum temperature difference is 69 K.
Worked example
A thermoelectric generator with ZT = 1 runs between 500 K and 300 K. What's its best efficiency?
Show the solution
- Carnot efficiency.
- Best thermoelectric efficiency.
- Where they're used. That's why thermoelectric generators are used where reliability matters more than efficiency: space probes, remote sensors, waste-heat recovery.
Answer the best efficiency is 8.2%.
Worked example
A thermoelectric generator module has S = 0.05 V/K and internal resistance 2 Ω. With 100 K across it, what's its open-circuit voltage, and what's the most power it can deliver?
Show the solution
- Open-circuit voltage.
- Matched load. The module behaves like a 5 V source behind 2 Ω, so the most power goes into a matched 2 Ω load: at a current of 1.25 A and 2.5 V across the load.
- The best-efficiency load. Because the current also carries Peltier heat back from the hot side and adds Joule heat, the load that gives the best efficiency is a little larger than the matched one:
Answer the open-circuit voltage is 5 V, and the module delivers at most 3.1 W, into a matched 2 Ω load.
Check
A thermocouple pair has relative Seebeck coefficient 52 µV/K. What voltage appears for a 50 K difference between its junctions?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A junction with Seebeck coefficient difference 200 µV/K carries 3 A at 250 K. At what rate does it absorb Peltier heat?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A Peltier module has S = 0.04 V/K, R = 1.5 Ω and K = 0.6 W/K. With its cold side at 280 K, what's the largest temperature difference it can hold?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
The same kind of module (S = 0.04 V/K, R = 1.5 Ω, K = 0.6 W/K) runs at 2 A with its cold side at 290 K and hot side at 300 K. How much heat does it pump?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A material has S = 150 µV/K, σ = 500 S/cm and κ = 1.5 W/(m·K). What's its ZT at 400 K?
Check
A generator with ZT = 1 runs between 450 K and 320 K. What's its best efficiency?
Check
A generator module has S = 0.02 V/K and internal resistance 1 Ω, with 150 K across it.
(a)
What's its open-circuit voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What's the most power it can deliver?
(c)
What current flows then?
Check
A material with Seebeck coefficient S (V/K), conductivity s (S/m) and thermal conductivity k (W/(m·K)), at T.
Step 1
What's its power factor, in W/(m·K²)?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's its figure of merit ZT?
Explain why
Why does a good thermoelectric material need low thermal conductivity as well as a large Seebeck coefficient?
A Peltier cooler pumps heat with the current, but heat also flows back from the hot side to the cold side by ordinary conduction through the same material, and Joule heating adds more. The pumped heat grows with the Seebeck coefficient, the Joule loss falls with higher electrical conductivity, and the back-leakage falls with lower thermal conductivity, so the best material combines all three, which is what measures. The difficulty is that electrons carry heat too, so raising σ tends to raise κ; good thermoelectrics are heavily doped semiconductors with heavy atoms that scatter phonons, cutting the lattice's share of κ while keeping the electrons mobile.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.