title: "Thermoelectric effects: Seebeck, Peltier and ZT"
heading: Turning heat into voltage, and current into cooling
eyebrow: "B11 · Lesson 28 · Thermoelectric effects: Seebeck, Peltier and ZT"
xp: 50
---

::: hook
Charge carriers carry heat as well as charge. Push a current through a junction of two materials and heat is absorbed on one side and released on the other: the **Peltier effect**, which cools the laser diodes in fiber-optic transmitters and the sensors in thermal cameras with no moving parts. Run it backward, hold the junctions at different temperatures, and a voltage appears: the **Seebeck effect**, which every thermocouple uses and which powers deep-space probes from the heat of decaying plutonium. One figure of merit, ZT, decides how well a material does either job, and it comes straight from transport and entropy.
:::

::: play
- A Peltier cooler module (Seebeck coefficient 0.051 V/K, resistance 2 Ω, thermal conductance 0.5 W/K) holds its hot side at 300 K. The curve is the heat pumped from the cold side against current, for the temperature difference you set.
- Small currents pump in proportion to I (the Peltier term). Large currents waste power as $I^2R$ Joule heat, half of which flows back to the cold side. In between there's an optimum (readout).
- Raise ΔT: heat leaking back through the module lowers the whole curve, until at about 69 K it can't pump anything: the module's maximum ΔT.
:::
:::

```sim plot
view: graph
x: I = 0..15 A
y: Q = -20..50 W
slider: d = 0..75 step 1 = 20 K
plot: 0.0508*(300 - d)*I - 0.5*I^2*2 - 0.5*d | label: heat pumped from the cold side, W
plot: 0 | dashed
readout: best current, A = 0.0508*(300 - d)/2
readout: most heat pumped, W = (0.0508*(300 - d))^2/4 - 0.5*d
readout: ZT at 300 K = 0.0508^2/(2*0.5)*300
```

::: predict
## A type K thermocouple has a Seebeck coefficient of about 41 µV/K. Its measuring junction is in boiling water and the reference junction at 0 °C. What voltage does it produce?

- [ ] 41 µV
- [x] About 4.1 mV
- [ ] About 0.41 V
- [ ] Nothing until a current flows

::: reveal
V = SΔT = 41 µV/K × 100 K = 4.1 mV (the standard table gives 4.096 mV). It's a small signal, which is why thermocouple amplifiers are high-gain, low-offset designs, and why the reference-junction temperature has to be measured too (cold-junction compensation).
:::
:::

::: nameit
## Seebeck

A temperature gradient across a conductor drives carriers from hot to cold until an electric field balances them. The open-circuit voltage per kelvin is the **Seebeck coefficient** S: a few µV/K in metals, hundreds of µV/K in semiconductors (positive for holes, negative for electrons). A loop of two materials A and B with junctions at different temperatures produces

$$V = (S_A - S_B)\Delta T$$

## Peltier

A current I through a junction carries heat at rate ΠI on each side, with a jump at the junction of $(\Pi_A - \Pi_B)I$. Kelvin's relation, from the second law, links the two effects:

$$\Pi = ST$$

S is the entropy carried per unit charge; Π is the heat.

## The thermoelectric cooler

A module with total Seebeck coefficient S, resistance R and thermal conductance K, cold side at $T_c$, ΔT across it:

$$Q_c = ST_cI - \frac12I^2R - K\Delta T$$

Best current $I = ST_c/R$, giving $Q_{c,max} = \frac{(ST_c)^2}{2R} - K\Delta T$. The largest ΔT it can hold (with $Q_c$ = 0) is $\Delta T_{max} = \frac12ZT_c^2$, with

$$Z = \frac{S^2}{RK} \quad\text{(module)}, \qquad ZT = \frac{S^2\sigma T}{\kappa}\quad\text{(material)}$$

## Figure of merit

Good thermoelectrics need a large S, high electrical conductivity σ (low Joule loss) and low thermal conductivity κ (little heat leaking back). Bismuth telluride reaches ZT ≈ 1 near room temperature. A generator's best efficiency is

$$\eta_{max} = \left(1 - \frac{T_c}{T_h}\right)\frac{\sqrt{1 + ZT} - 1}{\sqrt{1 + ZT} + T_c/T_h}$$

with T the mean temperature: about a fifth of Carnot at ZT = 1.
:::

::: example
## For the module in the sim, find Z, ZT at 300 K and the maximum temperature difference.

::: solution
1. **Figure of merit.**
   $$\begin{aligned} Z &= \frac{0.0508^2}{2 \times 0.5} \\ &= 2.58 \times 10^{-3}\ \text{K}^{-1} \end{aligned}$$
   so ZT = 0.77 at 300 K.
2. **Maximum temperature difference.** Solve
   $$\Delta T = \frac12ZT_c^2$$
   with $T_c = 300 - \Delta T$, which gives $T_c$ = 231 K and ΔT = 69 K.
3. **Compare with real modules.** Commercial single-stage modules quote about 70 K; for more, stack stages.

**Answer:** Z = 2.58 × 10⁻³ K⁻¹, ZT = 0.77 at 300 K, and the maximum temperature difference is 69 K.
:::
:::

::: example
## A thermoelectric generator with ZT = 1 runs between 500 K and 300 K. What's its best efficiency?

::: solution
1. **Carnot efficiency.**
   $$\begin{aligned} \eta_C &= 1 - \frac{300}{500} \\ &= 0.40 \end{aligned}$$
2. **Best thermoelectric efficiency.**
   $$\begin{aligned} \eta_{max} &= 0.40 \times \frac{\sqrt2 - 1}{\sqrt2 + 0.6} \\ &= 0.40 \times 0.206 \\ &= 8.2\% \end{aligned}$$
3. **Where they're used.** That's why thermoelectric generators are used where reliability matters more than efficiency: space probes, remote sensors, waste-heat recovery.

**Answer:** the best efficiency is 8.2%.
:::
:::

::: example
## A thermoelectric generator module has S = 0.05 V/K and internal resistance 2 Ω. With 100 K across it, what's its open-circuit voltage, and what's the most power it can deliver?

::: solution
1. **Open-circuit voltage.**
   $$S\Delta T = 5\ \text{V}$$
2. **Matched load.** The module behaves like a 5 V source behind 2 Ω, so the most power goes into a matched 2 Ω load:
   $$\begin{aligned} P_{max} &= \frac{(S\Delta T)^2}{4R} \\ &= \frac{25}{8} \\ &= 3.1\ \text{W} \end{aligned}$$
   at a current of 1.25 A and 2.5 V across the load.
3. **The best-efficiency load.** Because the current also carries Peltier heat back from the hot side and adds Joule heat, the load that gives the best efficiency is a little larger than the matched one:
   $$R_L = R\sqrt{1 + ZT}$$

**Answer:** the open-circuit voltage is 5 V, and the module delivers at most 3.1 W, into a matched 2 Ω load.
:::
:::

::: check
given: S = 41 | 52 | 6.5; d = 50 | 100 | 400
answer: S*d/1000
unit: mV
tolerance: 0.5%

## A thermocouple pair has relative Seebeck coefficient {S} µV/K. What voltage appears for a {d} K difference between its junctions?

::: right
Right. V = SΔT = {answer} mV.
:::

::: misses
- [S*d] Convert µV to mV.
- [any] Not yet. V = SΔT.
:::
:::

::: check
given: S = 200 | 400; T = 250 | 300; I = 1 | 3
answer: S*1e-6*T*I*1000
unit: mW
tolerance: 0.5%

## A junction with Seebeck coefficient difference {S} µV/K carries {I} A at {T} K. At what rate does it absorb Peltier heat?

::: right
Right. ΠI = STI = {answer} mW.
:::

::: misses
- [S*1e-6*I*1000] The Peltier coefficient is ST, not S.
- [any] Not yet. Kelvin's relation Π = ST.
:::
:::

::: check
given: S = 0.04 | 0.05; R = 1.5 | 3; K = 0.3 | 0.6; c = 250 | 280
answer: 0.5*S^2/(R*K)*c^2
unit: K
tolerance: 0.5%

## A Peltier module has S = {S} V/K, R = {R} Ω and K = {K} W/K. With its cold side at {c} K, what's the largest temperature difference it can hold?

::: right
Right. $\frac12ZT_c^2$ with $Z = \frac{S^2}{RK}$: {answer} K.
:::

::: misses
- [S^2/(R*K)*c^2] Include the ½: half the Joule heat flows to the cold side.
- [any] Not yet. Set $Q_c$ = 0 at the best current.
:::
:::

::: check
given: S = 0.04 | 0.05; R = 1.5 | 3; K = 0.3 | 0.6; c = 270 | 290; I = 2 | 5
answer: S*c*I - 0.5*I^2*R - K*(300 - c)
unit: W
tolerance: 0.5%

## The same kind of module (S = {S} V/K, R = {R} Ω, K = {K} W/K) runs at {I} A with its cold side at {c} K and hot side at 300 K. How much heat does it pump?

::: right
Right. $ST_cI - \frac12I^2R - K\Delta T$ = {answer} W.
:::

::: misses
- [S*c*I - I^2*R - K*(300 - c)] Only half the Joule heat ends up on the cold side.
- [any] Not yet. Peltier term minus half the Joule heat minus conduction.
:::
:::

::: check
given: S = 150 | 220; s = 500 | 1000; k = 1.2 | 1.5; T = 300 | 400
answer: (S*1e-6)^2*s*100*T/k
tolerance: 0.5%

## A material has S = {S} µV/K, σ = {s} S/cm and κ = {k} W/(m·K). What's its ZT at {T} K?

::: right
Right. $\frac{S^2\sigma T}{\kappa}$ = {answer}.
:::

::: misses
- [(S*1e-6)^2*s*T/k] Convert S/cm to S/m (×100).
- [any] Not yet. Use SI units throughout.
:::
:::

::: check
given: Z = 0.5 | 1 | 2; H = 450 | 700; C = 300 | 320
answer: (1 - C/H)*(sqrt(1 + Z) - 1)/(sqrt(1 + Z) + C/H)
tolerance: 0.5%

## A generator with ZT = {Z} runs between {H} K and {C} K. What's its best efficiency?

::: right
Right. {answer}.
:::

::: misses
- [1 - C/H] That's Carnot; thermoelectrics reach only a fraction of it.
- [any] Not yet. $\eta_C\frac{\sqrt{1 + ZT} - 1}{\sqrt{1 + ZT} + T_c/T_h}$.
:::
:::

::: check
kind: parts
given: S = 0.02 | 0.05; R = 1 | 3; d = 50 | 150

## A generator module has S = {S} V/K and internal resistance {R} Ω, with {d} K across it.

::: part
answer: S*d
unit: V
tolerance: 0.5%

### What's its open-circuit voltage?

::: misses
- [any] $V = S\Delta T$.
:::
:::

::: part
answer: (S*d)^2/(4*R)
unit: W
tolerance: 0.5%

### What's the most power it can deliver?

::: misses
- [(S*d)^2/R] That's into a short; the most power goes into a matched load.
- [any] $\frac{(S\Delta T)^2}{4R}$.
:::
:::

::: part
answer: S*d/(2*R)
unit: A
tolerance: 0.5%

### What current flows then?

::: misses
- [any] $\frac{S\Delta T}{2R}$.
:::
:::
:::

::: check
kind: derivation
vars: S = 0.0001..0.0005, s = 10000..1000000, k = 0.5..5, T = 200..800

## A material with Seebeck coefficient S (V/K), conductivity s (S/m) and thermal conductivity k (W/(m·K)), at T.

::: step
answer: S^2*s

### What's its power factor, in W/(m·K²)?
:::

::: step
answer: S^2*s*T/k

### What's its figure of merit ZT?
:::

::: right
Right. A good thermoelectric needs electrons that move easily while phonons don't, which is why heavy, complex semiconductors such as Bi₂Te₃ win.
:::
:::

::: explain
## Why does a good thermoelectric material need low thermal conductivity as well as a large Seebeck coefficient?

::: model
A Peltier cooler pumps heat with the current, but heat also flows back from the hot side to the cold side by ordinary conduction through the same material, and Joule heating adds more. The pumped heat grows with the Seebeck coefficient, the Joule loss falls with higher electrical conductivity, and the back-leakage falls with lower thermal conductivity, so the best material combines all three, which is what $ZT = S^2\sigma T/\kappa$ measures. The difficulty is that electrons carry heat too, so raising σ tends to raise κ; good thermoelectrics are heavily doped semiconductors with heavy atoms that scatter phonons, cutting the lattice's share of κ while keeping the electrons mobile.
:::
:::

::: practice

::: check
given: S = 8 | 60; d = 30 | 900
answer: S*d/1000
unit: mV
tolerance: 0.5%

## Thermocouple voltage: {S} µV/K over {d} K?

::: misses
- [any] SΔT.
:::
:::

::: check
given: S = 0.03 | 0.06; R = 1 | 4; K = 0.2 | 0.8; c = 230 | 290
answer: 0.5*S^2/(R*K)*c^2
unit: K
tolerance: 0.5%

## Max ΔT: S = {S}, R = {R}, K = {K}, $T_c$ = {c} K?

::: misses
- [any] $\frac12ZT_c^2$.
:::
:::

::: check
given: Z = 0.3 | 1.5; H = 400 | 900; C = 290 | 330
answer: (1 - C/H)*(sqrt(1 + Z) - 1)/(sqrt(1 + Z) + C/H)
tolerance: 0.5%

## Generator efficiency, ZT = {Z}, {H} K to {C} K?

::: misses