title: Ionic transport and electromigration
heading: Ions that move through solids, from oxygen sensors to sodium in gate oxides to wires that wear out
eyebrow: B12 · Lesson 45 · Ionic transport and electromigration
xp: 50
---

::: hook
Most of this course has been about electrons moving through a fixed lattice. But atoms move too, slowly, by hopping into the vacancies of lesson 44, and in the right materials and at the right temperatures they carry real current. A car's oxygen sensor is a ceramic that conducts oxygen ions, reporting the exhaust's oxygen as a voltage. The first MOS transistors drifted for years until engineers found sodium ions wandering through the gate oxide. And every chip's copper wiring slowly wears out because the electron current pushes the metal atoms themselves downstream. All three follow the same two rules: ions hop over a barrier, so their motion is thermally activated, and the Einstein relation ties their conductivity to their diffusion.
:::

::: play
- The conductivity of an ionic conductor against temperature, $\sigma T = A e^{-E_a/kT}$, on a log scale, normalized to 1 S/cm at 1000 K.
- Slide the activation energy: a barrier of 1 eV changes the conductivity by a factor of about 1400 between 1000 K and 600 K. Ionic conductors that work at room temperature need barriers of a few tenths of an eV.
- Black's equation for electromigration has the same exponential, so the same plot reads as a wire's life against temperature, upside down.
:::

```sim plot
view: graph
x: T = 300..1300
y: s = 1e-12..10 log
slider: Ea = 0.3..1.5 step 0.05 = 1
plot: 1000/T*exp(-Ea/(8.617e-5*T) + Ea/(8.617e-5*1000)) | label: σ in S/cm
readout: ratio from 1000 K to 600 K = (600/1000)*exp(Ea/8.617e-5*(1/600 - 1/1000)) | digits: 3
```

::: predict
## An oxygen sensor's ceramic conducts by oxygen vacancies with an activation energy of 1 eV. Going from 700 °C to 300 °C, its conductivity falls by roughly what factor?

- [ ] 2
- [ ] 50
- [x] 2500
- [ ] 10⁸

::: reveal
$\sigma \propto e^{-E_a/kT}/T$, so the ratio is $\frac{573}{973}e^{(1/8.617 \times 10^{-5})(1/573 - 1/973)}$ = 0.589 × $e^{8.33}$ ≈ 2400, more than three orders of magnitude. That's why lambda sensors carry their own heaters: below a few hundred degrees the ceramic stops conducting and the sensor goes blind, which used to make cold starts dirty.
:::
:::

::: nameit
## Hopping and the Einstein relation

An ion moves by jumping to a neighboring vacancy or interstitial site over a barrier $E_a$, so its diffusion coefficient is thermally activated, $D = D_0e^{-E_a/kT}$. A field biases the jumps, and the mobility follows from the Einstein relation $\mu = qD/kT$. With $n$ mobile ions of charge $q$ per volume, the conductivity is the **Nernst–Einstein relation**

$$\sigma = \frac{nq^2D}{kT}, \qquad \text{so} \qquad \sigma T = A\,e^{-E_a/kT}$$

An Arrhenius plot of $\ln(\sigma T)$ against $1/T$ is a straight line whose slope gives $E_a$.

## Solid electrolytes

Doping makes the mobile defects. Adding Y₂O₃ to ZrO₂ replaces Zr⁴⁺ with Y³⁺, and each pair of yttrium ions leaves one oxygen vacancy to keep the crystal neutral. Yttria-stabilized zirconia (YSZ) conducts oxide ions at about 0.1 S/cm near 1000 °C. As a sensor or fuel-cell membrane, it develops the Nernst voltage across it when the oxygen pressures on its two sides differ, with four electrons per O₂ molecule:

$$V = \frac{RT}{4F}\ln\frac{p_{O_2,1}}{p_{O_2,2}}$$

Lithium-ion batteries rely on the same idea with Li⁺ ions in liquid or solid electrolytes, and resistive memories (ReRAM) switch by forming and dissolving filaments of oxygen vacancies or metal ions.

## Mobile ions in gate oxides

Sodium ions in silicon dioxide drift under the gate field at moderate temperatures. Charge $Q$ per area sitting at a distance $x$ from the gate in an oxide of thickness $t_{ox}$ shifts the threshold by

$$\Delta V_T = -\frac{Q}{C_{ox}}\frac{x}{t_{ox}}$$

so ions piled at the silicon interface shift it fully and ions at the gate not at all. A **bias-temperature stress** test heats the device with the gate biased positive, then negative, and measures the shift between them to count the mobile charge.

## Electromigration

In a wire carrying a high current density $j$, electrons transfer momentum to the metal ions, a force called the electron wind. Atoms drift downstream along grain boundaries and interfaces, leaving voids that open the wire and hillocks that short it to a neighbor. **Black's equation** gives the median time to failure:

$$\text{MTTF} = A\,j^{-n}e^{E_a/kT}$$

with $n \approx 2$ and $E_a$ of 0.7 to 0.9 eV or so for aluminum and copper interconnect. Accelerated tests run at high current and temperature, and the equation extrapolates to use conditions.

Short wires survive any current up to a point: the atoms piling up at the downstream end build a stress gradient that pushes back, and below a critical product $(jL)_c$, the **Blech length** criterion, the drift stops. Typical values for copper interconnect are a few thousand amperes per centimeter.
:::

::: example
## 8 mol% Y₂O₃ in ZrO₂ makes a cubic crystal with lattice constant 0.514 nm and four cations per cell. Find its oxygen-vacancy density, then the vacancies' diffusion coefficient if it conducts 0.1 S/cm at 1273 K.

::: solution
1. **Cation density.**
   $$\begin{aligned} n_c &= \frac{4}{(0.514 \times 10^{-7}\ \text{cm})^3} \\ &= 2.95 \times 10^{22}\ \text{cm}^{-3} \end{aligned}$$
2. **Yttrium fraction.** With 8 Y₂O₃ for 92 ZrO₂, the yttrium fraction of cations is
   $$16/108 = 0.148$$
3. **Vacancy density.** There's one vacancy per two yttrium ions:
   $$\begin{aligned} n_v &= \frac{0.148}{2} \times 2.95 \times 10^{22} \\ &= 2.18 \times 10^{21}\ \text{cm}^{-3} \end{aligned}$$
4. **Diffusion coefficient.** A vacancy carries charge 2e, so Nernst–Einstein gives, with $kT/e$ = 0.1097 V,
   $$\begin{aligned} D &= \frac{\sigma kT}{n(2e)^2} \\ &= \frac{0.1 \times 0.1097}{4 \times 2.18 \times 10^{21} \times 1.602 \times 10^{-19}} \\ &= 7.9 \times 10^{-6}\ \text{cm}^2\text{/s} \end{aligned}$$
5. **What it means.** That leaves about 3.7% of the oxygen sites empty, and each vacancy jumps often enough at red heat to make the ceramic a fair conductor.

**Answer:** the oxygen-vacancy density is $2.18 \times 10^{21}$ cm⁻³, and the vacancies' diffusion coefficient is $7.9 \times 10^{-6}$ cm²/s.
:::
:::

::: example
## A zirconia oxygen sensor runs at 1000 K with air (0.21 atm of oxygen) on one side and exhaust on the other. What voltage does it give for rich exhaust with $10^{-20}$ atm of oxygen, and for lean exhaust with 0.01 atm?

::: solution
1. **The voltage scale.**
   $$\begin{aligned} \frac{RT}{4F} &= \frac{8.314 \times 1000}{4 \times 96\,485} \\ &= 21.5\ \text{mV} \end{aligned}$$
2. **Rich exhaust.**
   $$\begin{aligned} V_{rich} &= 21.5\ \text{mV} \times \ln\frac{0.21}{10^{-20}} \\ &= 0.958\ \text{V} \end{aligned}$$
3. **Lean exhaust.**
   $$\begin{aligned} V_{lean} &= 21.5\ \text{mV} \times \ln 21 \\ &= 66\ \text{mV} \end{aligned}$$
4. **The step at stoichiometry.** Around the stoichiometric mixture, the equilibrium oxygen pressure of the exhaust jumps by many orders of magnitude, so the sensor's output swings sharply between about 0.1 V and 0.9 V.
5. **How the engine uses it.** The engine controller doesn't need the voltage to be accurate, only to know which side of the step it's on.

**Answer:** the sensor gives 0.958 V for rich exhaust and 66 mV for lean exhaust.
:::
:::

::: example
## An electromigration test runs copper lines at 2 MA/cm² and 300 °C. The product will run them at 0.5 MA/cm² and 105 °C. With $n$ = 2 and $E_a$ = 0.9 eV, how much longer do they last in use? And with $(jL)_c$ = 3000 A/cm, how short must a line at 1 MA/cm² be to be immune?

::: solution
1. **Current factor.**
   $$\left(\frac{2}{0.5}\right)^2 = 16$$
2. **Temperature factor.** The Arrhenius exponent is
   $$\begin{aligned} \text{exponent} &= \frac{0.9}{8.617 \times 10^{-5}} \\ &\quad \times \left(\frac{1}{378.15} - \frac{1}{573.15}\right) \\ &= 9.40 \end{aligned}$$
3. **Lifetime ratio.**
   $$\begin{aligned} \frac{\text{MTTF}_{use}}{\text{MTTF}_{test}} &= 16 \times e^{9.40} \\ &= 1.93 \times 10^5 \end{aligned}$$
   A test median of 50 hours becomes about 1100 years.
4. **The activation energy matters.** With 0.7 eV the factor is only 2.4 × 10⁴, so a wrong $E_a$ can turn a comfortable margin into a field failure.
5. **Blech length.**
   $$\begin{aligned} L &< (jL)_c/j \\ &= 3000/10^6\ \text{cm} \\ &= 30\ \mu\text{m} \end{aligned}$$
6. **In layout.** Designers exploit this by breaking long power rails into short segments joined by vias.

**Answer:** the lines last $1.93 \times 10^5$ times longer in use, and a line at 1 MA/cm² is immune if it's shorter than 30 µm.
:::
:::

::: check
given: Ea = 0.5 | 0.8 | 1.1; T1 = 900 | 1100; T2 = 500 | 600
answer: (T2/T1)*exp(Ea/8.617e-5*(1/T2 - 1/T1))
tolerance: 1%

## An ionic conductor obeys $\sigma T = Ae^{-E_a/kT}$ with $E_a$ = {Ea} eV. By what factor does its conductivity at {T1} K exceed that at {T2} K?

::: right
Right. $\sigma_1/\sigma_2 = (T_2/T_1)e^{(E_a/k)(1/T_2 - 1/T_1)}$ = {answer}.
:::

::: misses
- [exp(Ea/8.617e-5*(1/T2 - 1/T1))] That's the exponential alone. Since $\sigma = Ae^{-E_a/kT}/T$, the ratio also carries a factor $T_2/T_1$.
- [(T1/T2)*exp(Ea/8.617e-5*(1/T2 - 1/T1))] The $1/T$ prefactor gives $T_2/T_1$, not $T_1/T_2$.
- [any] Not yet. Divide $\sigma = Ae^{-E_a/kT}/T$ at the two temperatures.
:::
:::

::: check
given: s = 0.01 | 0.05 | 0.1; n = 1 | 2 | 4; T = 1000 | 1200
answer: s*8.617e-5*T/(4*n*1e21*1.602e-19)
unit: cm²/s
tolerance: 1%

## A solid conducts {s} S/cm at {T} K by oxygen vacancies (charge 2e) at a density of {n} × 10²¹ cm⁻³. What is their diffusion coefficient, in cm²/s?

::: right
Right. $D = \sigma kT/(nq^2)$ with $q = 2e$: {answer}.
:::

::: misses
- [s*8.617e-5*T/(n*1e21*1.602e-19)] The vacancy's charge is $2e$, so $q^2 = 4e^2$.
- [s*8.617e-5*T/(2*n*1e21*1.602e-19)] Square the charge: $q^2 = 4e^2$, not $2e^2$.
- [any] Not yet. Invert $\sigma = nq^2D/kT$.
:::
:::

::: check
given: T = 600 | 800 | 1000; p = 1e-20 | 1e-10 | 0.01
answer: 8.314*T/(4*96485)*ln(0.21/p)
unit: V
tolerance: 0.5%

## A zirconia sensor at {T} K has air (0.21 atm of oxygen) on one side and {p} atm of oxygen on the other. What voltage does it develop?

::: right
Right. $V = (RT/4F)\ln(p_1/p_2)$ = {answer}.
:::

::: misses
- [8.314*T/(2*96485)*ln(0.21/p)] Each O₂ molecule takes four electrons, not two.
- [8.314*T/(4*96485)*log(0.21/p)] Use the natural logarithm.
- [any] Not yet. $V = \frac{RT}{4F}\ln\frac{0.21}{p}$.
:::
:::

::: check
kind: parts
given: N = 2 | 5 | 10; t = 5 | 10 | 20; f = 0.2 | 0.6 | 0.8

## Sodium ions at {N} × 10¹⁰ cm⁻² sit in a {t} nm SiO₂ gate oxide (κ = 3.9).

::: part
answer: 1.602e-19*N*1e10/(3.9*8.854e-14/(t*1e-7))*1e3
unit: mV
tolerance: 0.5%

### What threshold shift do they cause, in size, piled at the silicon interface?

::: misses
- [1.602e-19*N*1e10/(3.9*8.854e-14/(t*1e-7))] That's in volts; give millivolts.
- [any] Not yet. $|\Delta V_T| = qN/C_{ox}$ with $C_{ox} = \kappa\varepsilon_0/t_{ox}$.
:::
:::

::: part
answer: f*1.602e-19*N*1e10/(3.9*8.854e-14/(t*1e-7))*1e3
unit: mV
tolerance: 0.5%

### And if their centroid sits a fraction {f} of the way from the gate to the silicon?

::: misses
- [(1 - f)*1.602e-19*N*1e10/(3.9*8.854e-14/(t*1e-7))*1e3] Measure from the gate: charge at the gate itself shifts nothing.
- [any] Not yet. Scale the full shift by $x/t_{ox}$.
:::
:::

::: right
Right. Thicker oxides make the same charge matter more, which is why early thick-oxide MOS processes were so sensitive to sodium.
:::
:::

::: check
given: j1 = 1 | 2 | 3; j2 = 0.2 | 0.5; T1 = 250 | 300 | 350; T2 = 85 | 105; Ea = 0.7 | 0.9
answer: (j1/j2)^2*exp(Ea/8.617e-5*(1/(T2 + 273.15) - 1/(T1 + 273.15)))
tolerance: 1%

## An electromigration test runs at {j1} MA/cm² and {T1} °C; the product runs at {j2} MA/cm² and {T2} °C. With $n$ = 2 and $E_a$ = {Ea} eV in Black's equation, by what factor is the use lifetime longer?

::: right
Right. The current ratio squared times the Arrhenius factor: {answer}.
:::

::: misses
- [(j1/j2)^2*exp(Ea/8.617e-5*(1/T2 - 1/T1))] Use kelvins: add 273.15 to each temperature.
- [exp(Ea/8.617e-5*(1/(T2 + 273.15) - 1/(T1 + 273.15)))] Include the current-density factor $(j_1/j_2)^2$.
- [(j1/j2)*exp(Ea/8.617e-5*(1/(T2 + 273.15) - 1/(T1 + 273.15)))] The current exponent is $n$ = 2.
- [any] Not yet. $\text{MTTF} \propto j^{-2}e^{E_a/kT}$.
:::
:::

::: check
given: jl = 2000 | 3000 | 5000; j = 0.5 | 1 | 2
answer: jl/(j*1e6)*1e4
unit: µm
tolerance: 0.5%

## A process has a Blech product $(jL)_c$ = {jl} A/cm. Below what length, in µm, is a line carrying {j} MA/cm² immune to electromigration?

::: right
Right. $L_B = (jL)_c/j$ = {answer}.
:::

::: misses
- [jl/(j*1e6)] That's in centimeters. Multiply by 10⁴ for µm.
- [any] Not yet. Divide the Blech product by the current density.
:::
:::

::: check
kind: choice

## A bias-temperature stress test heats a MOS capacitor with +10 V on the gate, then −10 V, and measures the flat-band voltage after each. What does the difference between them measure?

- [x] The mobile ionic charge in the oxide, moved from one interface to the other
- [ ] The fixed oxide charge
- [ ] The interface-trap density
- [ ] The oxide's dielectric constant

::: right
Right. Heat lets the ions move; the bias sweeps them to the silicon side (full shift) or the gate side (none). Fixed charge and interface traps don't move, so the difference isolates the mobile part.
:::

::: misses
- [2] Fixed charge doesn't move with bias, so it shifts both measurements equally.
- [3] Interface traps stretch the C–V curve; they don't depend on which way the ions were swept.
- [4] The dielectric constant sets $C_{ox}$, which both measurements share.
:::
:::

::: check
kind: derivation
vars: n = 1e20..1e22, D = 1e-8..1e-5, T = 600..1300

## Find an ionic conductor's conductivity from its diffusion, in units of cm, s and S, for singly charged ions.

::: step
answer: D/(8.617e-5*T)

### The Einstein relation gives the mobility $\mu = qD/kT$. What is $\mu$ in cm²/(V·s), with $kT$ = 8.617 × 10⁻⁵$T$ eV?
:::

::: step
answer: n*1.602e-19*D/(8.617e-5*T)

### Then $\sigma = nq\mu$. What is $\sigma$ in S/cm?
:::

::: right
Right. $\sigma = nq^2D/kT$: the same diffusion that spreads ions out also carries current when a field biases their hops.
:::
:::

::: check
kind: python
given: Ea = 0.6 | 0.9 | 1.2

## An Arrhenius plot is how activation energies are measured. A conductor has $\sigma T = A e^{-E_a/kT}$ with $A = 10^6$ S·K/cm and $E_a$ = `Ea` = {Ea} eV. Measured values carry 3% random error: `T = [600, 700, 800, 900, 1000, 1100]` and `sigma` = the true values times `1 + 0.03*e` with `e = [0.5, -1, 0.3, 1, -0.6, -0.2]`. Fit a straight line to $\ln(\sigma T)$ against $1/kT$ by least squares (with `numpy.polyfit`) and set `Ea_fit` (eV) and `A_fit`.

```python starter
import numpy as np
T = np.array([600, 700, 800, 900, 1000, 1100.0])
e = np.array([0.5, -1, 0.3, 1, -0.6, -0.2])
sigma = 1e6 / T * np.exp(-Ea / (8.617e-5 * T)) * (1 + 0.03 * e)
Ea_fit = -np.polyfit(T, np.log(sigma), 1)[0]
A_fit = 1e6
print(Ea_fit)
```

```python solution
import numpy as np
k = 8.617e-5
T = np.array([600, 700, 800, 900, 1000, 1100.0])
e = np.array([0.5, -1, 0.3, 1, -0.6, -0.2])
sigma = 1e6 / T * np.exp(-Ea / (k * T)) * (1 + 0.03 * e)
slope, icpt = np.polyfit(1 / (k * T), np.log(sigma * T), 1)
Ea_fit, A_fit = -slope, np.exp(icpt)
print(Ea_fit, A_fit)
```

```python tests
import numpy as np
k = 8.617e-5
T = np.array([600, 700, 800, 900, 1000, 1100.0])
e = np.array([0.5, -1, 0.3, 1, -0.6, -0.2])
y = np.log(1e6 / T * np.exp(-Ea / (k * T)) * (1 + 0.03 * e) * T)
x = 1 / (k * T)
s, c = np.polyfit(x, y, 1)
assert abs(Ea_fit + s) < 1e-9, f"Fit ln(σT) against 1/kT: the slope is −Ea, giving {-s:.5f} eV."
assert abs(A_fit / np.exp(c) - 1) < 1e-9, "A is the exponential of the intercept."
assert abs(Ea_fit - Ea) < 0.02, "With 3% noise, the fitted Ea should land within 0.02 eV of the true value."
```

::: right
Right. The 1/T prefactor matters: fitting $\ln\sigma$ instead of $\ln(\sigma T)$ lowers the apparent activation energy by about $kT$ at the middle of the range, 0.07 eV here.
:::
:::

::: explain
## Why does a long copper line on a chip fail by electromigration at a current density that a short line of the same width survives indefinitely?

::: model
The electron wind pushes copper atoms toward the anode end of the line. In a short line, the atoms can't leave: they pile up against the barrier at the via, which builds compressive stress there and tensile stress at the cathode end. That stress gradient pushes atoms back upstream, and when it balances the wind, the net drift stops before a void can grow large enough to matter. The back-stress that can build up is limited by what the line and its surroundings can bear, while the wind's push grows with current density, and the stress gradient needed is the tolerable stress divided by the length. So a line shorter than $(jL)_c/j$ reaches balance, while a longer one can't build a steep enough gradient, its atoms keep draining from the cathode end, and a void eventually opens the line.
:::
:::

::: practice

::: check
given: T = 700 | 900 | 1100; p = 1e-15 | 1e-5
answer: 8.314*T/(4*96485)*ln(0.21/p)
unit: V
tolerance: 0.5%

## An oxygen sensor at {T} K sees air on one side and {p} atm of oxygen on the other. What voltage does it give?

::: misses
- [8.314*T/(2*96485)*ln(0.21/p)] Four electrons per O₂ molecule.
- [any] $V = (RT/4F)\ln(0.21/p)$.
:::
:::

::: check
given: j = 1.5 | 2 | 4; Ea = 0.7 | 0.9
answer: j^2*exp(Ea/8.617e-5*(1/358.15 - 1/523.15))
tolerance: 1%

## A test at {j} times the use current density runs at 250 °C against 85 °C in use. With $n$ = 2 and $E_a$ = {Ea} eV, what's the acceleration factor?

::: misses
- [j*exp(Ea/8.617e-5*(1/358.15 - 1/523.15))] Square the current ratio.
- [any] Multiply $(j_1/j_2)^2$ by the Arrhenius factor in kelvins.
:::
:::
:::