B12 · Lesson 43 · Piezoelectric and ferroelectric devices
Crystal resonators, actuators and sensors, and where a ferroelectric's polarization comes from
Every computer, phone and radio keeps time with a sliver of quartz that rings when a voltage squeezes it. Lesson 42 met piezoelectricity and ferroelectrics in a paragraph each; this lesson builds the circuit models engineers actually use. To an oscillator, a quartz crystal is a series RLC with an inductance of millihenries and a Q of tens of thousands, shunted by a few picofarads, and that model explains why the frequency depends on the load capacitance printed on the datasheet. The same physics stretched across a stack of ceramic layers moves a fuel injector or a disk-drive head by micrometers, and turned around it measures force. Ferroelectrics such as PZT get their huge response from a spontaneous polarization, and Landau's free-energy expansion shows where that polarization comes from and why its permittivity spikes near the Curie point.
- The impedance magnitude of a 10 MHz crystal in the Butterworth–Van Dyke model: a motional branch ( = 10 Ω, = 10.1 mH, = 25 fF) in parallel with the electrode capacitance . The horizontal axis is the offset from the series resonance in kHz.
- At zero offset the motional branch's reactances cancel and falls to . A little higher, the motional branch looks inductive and resonates with : the parallel (anti-)resonance, where peaks.
- Raise and the parallel resonance moves toward the series one: the gap is about .
Predict
A 10 MHz crystal has = 25 fF and = 5 pF. It's specified for an 18 pF load capacitance, but the board's load is really 15 pF. Roughly how far off is the frequency?
In a parallel-mode oscillator, the crystal runs where its motional branch resonates with , which is . The offset from is about : 543 ppm at 18 pF and 625 ppm at 15 pF. The smaller load pulls the frequency up by about 80 ppm, while a typical crystal is specified to 20 or 30 ppm. That's why board designers compute the load capacitance, stray capacitance included, before choosing the two capacitors at the oscillator's pins.
Name it
Piezoelectric constitutive equations
In a piezoelectric crystal, strain and polarization are coupled. Along one axis,
where is strain, stress, field, displacement, the compliance at constant field and the piezoelectric coefficient in C/N (equivalently m/V). Read one way, a stress makes charge, for a force on a plate; read the other, a field makes strain, for a voltage across a plate. The coupling coefficient , with , is the fraction of stored energy converted between the electrical and mechanical forms. Quartz has = 2.3 pC/N and small ; PZT ceramics reach hundreds of pC/N and near 0.7.
Only crystals without a center of symmetry can be piezoelectric: squeezing a centrosymmetric crystal can't create a polarization that would have to point in some direction. Silicon is centrosymmetric, so silicon MEMS resonators and filters use deposited films of aluminum nitride or PZT for transduction.
The Butterworth–Van Dyke model
Near one resonance, a piezoelectric resonator is a motional branch , , (the mechanical mass, compliance and loss, seen through the piezoelectric coupling) in parallel with , the ordinary capacitance of the electrodes.
For a thickness-mode plate at its fundamental, , so a weakly coupled material like quartz has its two resonances close together, and the frequency can be pulled only slightly. That's the price of its stability.
With a load capacitance in series, the operating frequency is
and its sensitivity, the trim sensitivity, is about per farad of load.
Ferroelectrics and Landau theory
A ferroelectric has a spontaneous polarization that an applied field can reverse. Landau expanded the free energy density in the polarization:
with . Setting :
- Above , the minimum at zero field is , and the susceptibility is : the Curie–Weiss law, with .
- Below , , and the susceptibility is half what Curie–Weiss gives at the same distance from .
- The curve with turns back on itself; its turning points give the intrinsic coercive field .
Measured coercive fields are far smaller than the intrinsic one, because real crystals switch by nucleating and growing domains instead of reversing everywhere at once. The permittivity peak near is why barium titanate capacitors (X7R and similar classes) pack so much capacitance into a small volume, and why their capacitance drifts with temperature and falls with DC bias.
Worked example
A 10 MHz crystal has = 10 Ω, = 25 fF and = 5 pF. Find , , the parallel resonance and the frequency offset with an 18 pF load, and its trim sensitivity there.
Show the solution
- Motional inductance.
- Quality factor.
- Parallel resonance.
- Offset with an 18 pF load. With = 18 pF, = 23 pF and the crystal runs above .
- Trim sensitivity.
- Why crystals win. A millihenry-scale inductor with a Q of 60 000 is impossible to wind; the crystal gets it from mechanical motion, which is why a crystal oscillator beats any LC oscillator for stability by orders of magnitude.
Answer = 10.13 mH and Q = 63 700, the parallel resonance is 24.97 kHz above , and with an 18 pF load the crystal runs 543 ppm above , with a trim sensitivity of 23.6 ppm per pF.
Worked example
A multilayer PZT stack actuator has 200 layers, each 100 µm thick, with = 500 pC/N. What stroke does 150 V give? And a quartz force sensor ( = 2.3 pC/N) feeds a charge amplifier with a 100 pF feedback capacitor: what output does 10 N give?
Show the solution
- Each layer. Each layer sees the full 150 V, a field of 1.5 kV/mm, and stretches by .
- Stroke.
- Why thin layers. The layers are electrically in parallel and mechanically in series, which is why stacks are built thin-layered: the same stroke from one 20 mm block would need 30 kV.
- Sensor charge.
- Charge amplifier output. independent of the cable's capacitance.
- Why charge amplifiers. That independence is the reason piezoelectric sensors use charge amplifiers instead of voltage amplifiers, whose gain the cable capacitance would divide.
Answer the stack's stroke is 15 µm at 150 V, and the sensor's charge amplifier puts out 0.23 V for 10 N.
Worked example
A ferroelectric follows Landau's second-order model with Curie constant K, = 400 K and J·m⁵/C⁴. Find its permittivity 20 K above , its spontaneous polarization at 300 K, and its intrinsic coercive field there.
Show the solution
- Permittivity 20 K above the transition.
- Landau coefficient. so at 300 K, .
- Spontaneous polarization.
- Coercive field.
- Compare with real ceramics. The polarization is close to barium titanate's, but real ceramics switch at a few kilovolts per centimeter. The intrinsic field is an upper limit that domain-wall motion undercuts.
Answer the permittivity 20 K above is about 7500; at 300 K the spontaneous polarization is 27.4 µC/cm² and the intrinsic coercive field 79.5 kV/cm.
Check
A PZT stack has 200 layers with = 300 pC/N, each driven by 150 V. What stroke does it give, in µm?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
Check
A crystal has series resonance at 10 MHz, = 10 fF, = 7 pF and = 40 Ω.
(a)
What is its motional inductance, in mH?
Write units the way you normally would: 1.5 mH, 1500 µH and 0.0015 H are the same answer.
(b)
What is its Q?
(c)
How far above the series resonance is the parallel resonance, in kHz?
Check
A crystal with = 20 fF and = 3 pF runs with a load capacitance of 18 pF. In ppm, how far above its series resonance does it oscillate?
Check
A quartz force sensor ( = 2.3 pC/N) carries 5 N and feeds a charge amplifier with a 47 pF feedback capacitor. What is the output voltage's size?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A ferroelectric follows Landau's second-order model with Curie constant 1.5 × 10⁵ K and J·m⁵/C⁴.
(a)
What is its relative permittivity 25 K above ?
(b)
What is its spontaneous polarization 50 K below , in µC/cm²?
Write units the way you normally would: 1.5 µC/cm², 1500 nC/cm² and 0.0015 mC/cm² are the same answer.
Check
A designer wants a piezoelectric resonator on a silicon MEMS chip. Why can't the silicon itself be the piezoelectric?
Check
Landau's free energy is with below the transition ( = , ).
Step 1
Set and minimize. What is ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
The field has turning points where . At what ?
Step 3
What is the size of there, the intrinsic coercive field?
Check
Model a crystal in Python. f0 = 10 MHz is the series resonance, C1 = 15 fF and C0 = 6 pF, with = 10 Ω. Write bvd(f) returning the complex impedance at frequency f in Hz; set L1 in henries, fp (the exact lossless parallel resonance, Hz), and write pull_ppm(CL) giving the exact offset above f0 in ppm for a load capacitance CL in pF.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why does a crystal oscillator's frequency depend on the load capacitance, and why does a quartz crystal let the designer pull it only a little, compared with a ceramic resonator?
In a parallel-mode oscillator, the crystal's motional branch resonates in series with , the electrode capacitance plus the circuit's load. That combination is smaller than alone would be in series with nothing, so the frequency rises above the series resonance by about , and changing changes it. How large that offset can be depends on , which for a thickness-mode resonator is , with the coupling coefficient. Quartz couples weakly, so is a tiny fraction of , the frequency moves only hundreds of ppm across the whole range of loads, and stray capacitance barely disturbs it. A PZT-type ceramic resonator couples strongly, so its is much larger: it can be pulled much further, but for the same reason its frequency is far less stable.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.