B4 · Lesson 3 · Resistance from shape and material
Longer is more, thicker is less
Every wire, trace and heating element has a resistance you can predict from three numbers: what it's made of, how long it is, and how thick. Long thin nichrome makes a toaster element; short thick copper makes a battery cable. The rule is the same, and it tells you how thick a cable has to be for a given current, why power lines run at high voltage, and how a strain gauge senses stretching.
Play
- A round wire of length and diameter is made of a material with resistivity ρ. The graph shows its resistance against length.
- Double the length. Double the diameter. What happens to the resistance each time?
- Change the material from copper to nichrome. How long a piece of nichrome has the same resistance as 100 m of copper?
Predict
You replace a wire with one of the same material and length but twice the diameter. What happens to its resistance?
A quarter. The cross-sectional area goes as the diameter squared, so twice the diameter means four times the area: four times as many parallel paths for the current. That's why cable sizes jump quickly in area, and why a wire's current rating grows faster than its diameter.
Name it
Resistance of a conductor
For a uniform piece of material of length and cross-sectional area :
Longer means more resistance (like resistors in series); larger area means less (like resistors in parallel). For a round wire, .
Resistivities at 20 °C:
| Material | ρ (Ω·m) |
|---|---|
| silver | |
| copper | |
| aluminum | |
| nichrome (heating elements) | |
| carbon (graphite) | about |
| pure silicon | about |
| glass | to |
Silver is the best conductor but copper is nearly as good and far cheaper. Aluminum, with 60% more resistivity but a third the density, wins for overhead power lines, where weight matters.
Sheet resistance. Thin films, like copper on a circuit board, are described by their sheet resistance , in ohms per square: a square of any size has the same resistance edge to edge. Standard 35 µm board copper is about 0.5 mΩ per square, so a trace 100 squares long (say 0.25 mm wide and 25 mm long) is 50 mΩ.
Wire gauge. American Wire Gauge numbers go down as wires get thicker; every 3 gauges halves the area. 12 AWG (2.05 mm, for 20 A house circuits) is about 5 mΩ per meter.
Strain gauges use the shape dependence: stretching a thin wire makes it longer and thinner, raising its resistance in proportion to the strain.
Worked example
What is the resistance of 10 m of copper wire with a 0.5 mm² cross-section?
Show the solution
- Resistance from shape.
Answer the wire has 0.34 Ω.
Worked example
A board trace in 1 oz copper (35 µm thick) is 0.25 mm wide and 50 mm long. Find the sheet resistance and the trace's resistance.
Show the solution
- Sheet resistance. per square.
- Count the squares.
- Trace resistance.
Answer the sheet resistance is 0.49 mΩ per square, and the trace has 98 mΩ.
Check
What is the resistance of 36 m of copper wire 0.5 mm in diameter? (ρ = 1.68 × 10⁻⁸ Ω·m.)
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A wire's diameter is made 3 times larger. By what factor does its resistance change?
Check
How long a piece of nichrome wire 0.2 mm in diameter gives 40 Ω? (ρ = 1.1 × 10⁻⁶ Ω·m.)
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
A board trace is 80 squares long, in copper with a sheet resistance of 0.5 mΩ per square. What is its resistance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
10 A flows through 10 m of copper wire 2 mm across. How much power does the wire waste as heat?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A copper wire ( = 1.68 × 10⁻⁸ Ω·m at 20 °C, α = 0.0039 /°C) is 10 m long and 0.25 mm in diameter.
(a)
What is its resistance at 20 °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
And at 80 °C?
Explain why
Why does resistance grow with a conductor's length but fall with its cross-sectional area?
A longer conductor is like several shorter pieces in series: the current has to push through each one in turn, so their resistances add. A thicker conductor is like several thin ones side by side: the current divides among many parallel paths, so the resistance falls in proportion to how many there are, which is to say in proportion to the area. Together these give , with the material's resistivity setting the scale.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.