B5 · Lesson 13 · The Hall effect
A sideways voltage that reveals the charge carriers
Push current along a flat strip with a magnetic field through its face, and the Lorentz force pushes the moving charges toward one edge. They pile up there until their own electric field balances the magnetic push, leaving a small voltage across the strip's width. That voltage tells you the field's strength, the density of carriers, and even whether they're negative electrons or positive holes. It's the basis of the sensors that measure current in power supplies, the position of a brushless motor's rotor, and the speed of a car's wheels.
Play
- Current flows along a strip of thickness in a field . The graph shows the Hall voltage against the field, for a material with carrier density .
- Compare copper ( m⁻³) with a doped semiconductor ( to ). Which gives a usable voltage?
- Make the strip thinner. What happens?
Predict
The same current flows through a copper strip and a doped silicon strip of the same size, in the same field. Which shows the larger Hall voltage?
Silicon, by orders of magnitude. With fewer carriers, each one has to move faster to carry the same current, so the magnetic force on each is larger and a larger field is needed to balance it. Copper's Hall voltage is far too small to use for sensing, which is why Hall sensors are made from semiconductors.
Name it
The Hall effect
The balance. Carriers of charge drifting at through a field feel the sideways force . They pile up on one edge until the electric field across the strip pushes back equally: . Across the strip's width , that's a voltage .
In terms of current. With for a strip of thickness :
Fewer carriers or a thinner strip gives a bigger voltage. The width cancels out.
What it tells you.
- The field: for a known current and material, . That's a Hall-effect magnetometer.
- The carrier density: . Physicists measure it this way.
- The carrier's sign: electrons and holes pile up on opposite edges, so the Hall voltage has opposite signs. The Hall effect is how p-type semiconductors were shown to conduct by positive carriers.
Sensors. A typical linear Hall sensor chip, a thin piece of doped semiconductor with an amplifier built in, gives a few to tens of millivolts per millitesla, enough to sense a small magnet a few millimeters away. They measure current without touching the circuit (by sensing the field around a conductor), detect the position of brushless motors' rotors, count gear teeth for speed, and replace mechanical switches in keyboards and joysticks.
Worked example
A copper strip 0.1 mm thick carries 10 A in a 1 T field. What Hall voltage appears?
Show the solution
- Carrier charge per area.
- Hall voltage.
- Why it's tiny. Copper has so many carriers that each drifts slowly.
Answer only 7.3 µV appears.
Worked example
A semiconductor Hall sensor has carriers per m³ and is 0.1 mm thick. What voltage does 1 mA in 0.1 T give?
Show the solution
- Carrier charge per area.
- Hall voltage.
- Compare with copper. That's nearly a thousand times copper's, at a ten-thousandth of the current. Few carriers drift fast, which is why Hall sensors are made of lightly doped semiconductors.
Answer 1 mA in 0.1 T gives 6.2 mV.
Check
A strip 500 µm thick carries 4 mA in a 0.1 T field. Its carrier density is 10 × 10²¹ m⁻³. What is the Hall voltage, in mV?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A copper strip 0.1 mm thick carries 5 A in a 1 T field. What is its Hall voltage, in nV? (n = 8.5 × 10²⁸ m⁻³.)
Write units the way you normally would: 1.5 nV, 1500 pV and 0.0015 µV are the same answer.
Check
A 200 µm strip carrying 2 mA in 0.5 T shows a Hall voltage of 100 mV. What is its carrier density?
Check
Two samples carry current the same way through the same field. One shows a positive Hall voltage, the other negative. What does that tell you?
Check
A Hall sensor's sensitivity is 20 mV/mT. What does it read in a 2 mT field?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A Hall sample 1 mm thick carries 10 mA in a 0.1 T field and shows a Hall voltage of 50 µV. What is its carrier density?
Explain why
Why does the Hall voltage stop growing once the carriers have piled up?
The magnetic force pushes moving carriers toward one edge, and as they accumulate they create an electric field across the strip that pushes them back. The pile-up continues only while the magnetic push is stronger. Once the electric field is strong enough that equals , the carriers flowing along the strip feel no net sideways force, so no more pile up and the voltage stays steady.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.