B5 · Lesson 11 · Magnetic circuits
Ampere-turns, reluctance, and why inductors have air gaps
A transformer core, a relay, a motor's stator: each guides magnetic flux around a loop of iron, as a wire guides current. Flux is conserved along the core (lesson 9), the coil's ampere-turns push it, and the core resists it, so the whole thing can be solved with Ohm's law, swapping in magnetic quantities. The analogy explains a puzzle about inductors: why would anyone cut a gap in a beautiful high-permeability core? Because a half-millimeter of air can dominate the circuit and make the inductor predictable.
- A coil of turns sits on a ferrite core with a 10 cm path, 1 cm² cross-section and relative permeability . A gap of length is cut in the core.
- The curve is the inductance against the gap. With no gap it's huge but depends entirely on ; with even a small gap, it drops and nearly stops caring about .
- The readout shows what fraction of the circuit's reluctance sits in the gap.
Predict
A ferrite core with a 10 cm magnetic path ( = 2000) has a 0.5 mm air gap cut in it. What share of the circuit's reluctance is in that tiny gap?
About 91%. The core's 100 mm of path, divided by = 2000, acts like 0.05 mm of air; the gap is 0.5 mm of real air, ten times more. So nearly all the reluctance, and nearly all the stored energy, sits in the gap. The inductance then depends mostly on the gap's dimensions, which are easy to make precisely, not on , which drifts with temperature and current.
Name it
The analogy
| Electric circuit | Magnetic circuit |
|---|---|
| EMF (V) | magnetomotive force (ampere-turns) |
| current | flux Φ (Wb) |
| resistance | reluctance (A/Wb) |
with the path length, the cross-section and . It works because flux is conserved around the core (no field lines end) and Ampère's law gives . Reluctances in series add, like resistances.
Core and gap
A core of length with a gap :
Because is in the thousands, a gap a fraction of a millimeter long can outweigh the whole core.
Inductance
With flux linkage ,
Gaps are cut deliberately: they make stable against changes in , they keep the core out of saturation at high current (the same current gives a lower ), and they store the energy in an inductor meant to store it, such as a switching converter's. Transformers, which want the most coupling and least magnetizing current, are built without gaps.
Flux density
must stay below the core's saturation, about 0.3 T for ferrite and 1.5 to 2 T for silicon steel.
Worked example
A 100-turn coil on that core (10 cm path, 1 cm², = 2000, 0.5 mm gap). Find its reluctance, inductance, and the flux density at 1 A.
Show the solution
- Core reluctance.
- Gap reluctance.
- Total reluctance.
- Inductance.
- Flux and flux density at 1 A. just under ferrite's saturation.
Answer the total reluctance is A/Wb, the inductance is 2.3 mH, and at 1 A the flux density is 0.23 T, just under ferrite's saturation.
Worked example
Without the gap, what would the inductance be, and what would happen at 1 A?
Show the solution
- Inductance without the gap. Only the core's reluctance is left: eleven times more.
- Flux density at 1 A. It would be 2.5 T, far past ferrite's saturation near 0.3 T.
- What happens. The core would saturate and the inductance would collapse. The gapped design trades inductance for current-handling.
Answer without the gap the inductance would be 25 mH, but at 1 A the core would saturate and the inductance would collapse.
Check
A core has a 5 cm path, 2 cm² cross-section and = 1000. What is its reluctance?
Write units the way you normally would: 1.5 kA/Wb, 1500 A/Wb and 0.0015 MA/Wb are the same answer.
Check
What is the reluctance of a 0.2 mm air gap across 0.5 cm²?
Write units the way you normally would: 1.5 MA/Wb, 1500 kA/Wb and 0.0015 GA/Wb are the same answer.
Check
A coil of 50 turns sits on a magnetic circuit with a total reluctance of 1 × 10⁶ A/Wb. What is its inductance?
Write units the way you normally would: 1.5 mH, 1500 µH and 0.0015 H are the same answer.
Check
A coil of 50 turns carries 0.5 A on a circuit of reluctance 5 × 10⁶ A/Wb and 2 cm² cross-section. What is the flux density in the core?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
A core with a 10 cm path and = 1000 has a 1 mm gap. What percentage of the reluctance is in the gap?
Check
A coil's turns are multiplied by 3 on the same core. By what factor does its inductance change?
Explain why
Why does cutting an air gap make an inductor's value more stable?
An inductor's value is over the total reluctance of its flux path. The core's reluctance depends on its permeability, which varies a lot with temperature, with the current flowing, and from one core to the next. An air gap adds a reluctance that depends only on its length and area, and because air's permeability is thousands of times lower, even a thin gap can outweigh the whole core. Then the total reluctance, and the inductance, depend mostly on the gap, and the core's wandering permeability hardly matters.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.