title: Magnetic circuits
heading: Ampere-turns, reluctance, and why inductors have air gaps
eyebrow: B5 · Lesson 11 · Magnetic circuits
xp: 40
---

::: hook
A transformer core, a relay, a motor's stator: each guides magnetic flux around a loop of iron, as a wire guides current. Flux is conserved along the core (lesson 9), the coil's ampere-turns push it, and the core resists it, so the whole thing can be solved with Ohm's law, swapping in magnetic quantities. The analogy explains a puzzle about inductors: why would anyone cut a gap in a beautiful high-permeability core? Because a half-millimeter of air can dominate the circuit and make the inductor predictable.
:::

::: play
- A coil of $N$ turns sits on a ferrite core with a 10 cm path, 1 cm² cross-section and relative permeability $\mu_r$. A gap of length $g$ is cut in the core.
- The curve is the inductance against the gap. With no gap it's huge but depends entirely on $\mu_r$; with even a small gap, it drops and nearly stops caring about $\mu_r$.
- The readout shows what fraction of the circuit's reluctance sits in the gap.
:::
:::

```sim plot
view: graph
x: g = 0..2 mm
y: L = 0..30 mH
slider: N = 50..200 step 10 = 100
slider: ur = 500..5000 step 100 = 2000
plot: N^2/(0.1/(ur*4*pi*1e-7*1e-4) + (g/1000)/(4*pi*1e-7*1e-4))*1000 | label: inductance
readout: inductance with a 0.5 mm gap, mH = N^2/(0.1/(ur*4*pi*1e-7*1e-4) + 5e-4/(4*pi*1e-7*1e-4))*1000 | digits: 4
readout: share of reluctance in a 0.5 mm gap, % = 100*(5e-4)/(0.1/ur + 5e-4) | digits: 3
```

::: predict
## A ferrite core with a 10 cm magnetic path ($\mu_r$ = 2000) has a 0.5 mm air gap cut in it. What share of the circuit's reluctance is in that tiny gap?

- [ ] About 0.5%
- [ ] About 9%
- [ ] About 50%
- [x] About 91%

::: reveal
About 91%. The core's 100 mm of path, divided by $\mu_r$ = 2000, acts like 0.05 mm of air; the gap is 0.5 mm of real air, ten times more. So nearly all the reluctance, and nearly all the stored energy, sits in the gap. The inductance then depends mostly on the gap's dimensions, which are easy to make precisely, not on $\mu_r$, which drifts with temperature and current.
:::
:::

::: nameit
## The analogy

| Electric circuit | Magnetic circuit |
|---|---|
| EMF $\mathcal E$ (V) | magnetomotive force $\mathcal F = NI$ (ampere-turns) |
| current $I$ | flux Φ (Wb) |
| resistance $R = \frac{L}{\sigma A}$ | reluctance $\mathcal R = \frac{l}{\mu A}$ (A/Wb) |
| $I = \mathcal E/R$ | $\Phi = \mathcal F/\mathcal R$ |

with $l$ the path length, $A$ the cross-section and $\mu = \mu_r\mu_0$. It works because flux is conserved around the core (no field lines end) and Ampère's law gives $\oint\mathbf H \cdot d\mathbf l = NI$. Reluctances in series add, like resistances.

## Core and gap

A core of length $l_c$ with a gap $g$:

$$\mathcal R = \frac{l_c}{\mu_r\mu_0A} + \frac{g}{\mu_0A}$$

Because $\mu_r$ is in the thousands, a gap a fraction of a millimeter long can outweigh the whole core.

## Inductance

With flux linkage $N\Phi = N\frac{NI}{\mathcal R}$,

$$L = \frac{N^2}{\mathcal R}$$

Gaps are cut deliberately: they make $L$ stable against changes in $\mu_r$, they keep the core out of saturation at high current (the same current gives a lower $B$), and they store the energy in an inductor meant to store it, such as a switching converter's. Transformers, which want the most coupling and least magnetizing current, are built without gaps.

## Flux density

$B = \frac{\Phi}{A}$ must stay below the core's saturation, about 0.3 T for ferrite and 1.5 to 2 T for silicon steel.
:::

::: example
## A 100-turn coil on that core (10 cm path, 1 cm², $\mu_r$ = 2000, 0.5 mm gap). Find its reluctance, inductance, and the flux density at 1 A.

::: solution
1. **Core reluctance.**
   $$\begin{aligned} \mathcal R_\text{core} &= \frac{0.1}{2000 \times 4\pi \times 10^{-7} \times 10^{-4}} \\ &= 3.98 \times 10^5\ \text{A/Wb} \end{aligned}$$
2. **Gap reluctance.**
   $$\begin{aligned} \mathcal R_\text{gap} &= \frac{5 \times 10^{-4}}{4\pi \times 10^{-7} \times 10^{-4}} \\ &= 3.98 \times 10^6\ \text{A/Wb} \end{aligned}$$
3. **Total reluctance.**
   $$\begin{aligned} \mathcal R &= 3.98 \times 10^5 + 3.98 \times 10^6 \\ &= 4.38 \times 10^6\ \text{A/Wb} \end{aligned}$$
4. **Inductance.**
   $$\begin{aligned} L &= \frac{100^2}{4.38 \times 10^6} \\ &= 2.3\ \text{mH} \end{aligned}$$
5. **Flux and flux density at 1 A.**
   $$\begin{aligned} \Phi &= \frac{100}{4.38 \times 10^6} \\ &= 2.3 \times 10^{-5}\ \text{Wb} \\ B &= \frac{\Phi}{A} \\ &= 0.23\ \text{T} \end{aligned}$$
   just under ferrite's saturation.

**Answer:** the total reluctance is $4.38 \times 10^6$ A/Wb, the inductance is 2.3 mH, and at 1 A the flux density is 0.23 T, just under ferrite's saturation.
:::
:::

::: example
## Without the gap, what would the inductance be, and what would happen at 1 A?

::: solution
1. **Inductance without the gap.** Only the core's reluctance is left:
   $$\begin{aligned} L &= \frac{10^4}{3.98 \times 10^5} \\ &= 25\ \text{mH} \end{aligned}$$
   eleven times more.
2. **Flux density at 1 A.** It would be 2.5 T, far past ferrite's saturation near 0.3 T.
3. **What happens.** The core would saturate and the inductance would collapse. The gapped design trades inductance for current-handling.

**Answer:** without the gap the inductance would be 25 mH, but at 1 A the core would saturate and the inductance would collapse.
:::
:::

::: check
given: l = 5 | 15; ur = 1000 | 3000; A = 0.5 | 2
answer: (l/100)/(ur*4*pi*1e-7*A*1e-4)/1000
unit: kA/Wb
tolerance: 0.5%

## A core has a {l} cm path, {A} cm² cross-section and $\mu_r$ = {ur}. What is its reluctance?

::: right
Right. $\frac{l}{\mu_r\mu_0A}$ = {answer}.
:::

::: misses
- [(l/100)/(4*pi*1e-7*A*1e-4)/1000] Include the core's relative permeability.
- [any] Not yet. $\mathcal R = l/(\mu A)$.
:::
:::

::: check
given: g = 0.2 | 1; A = 0.5 | 2
answer: (g/1000)/(4*pi*1e-7*A*1e-4)/1e6
unit: MA/Wb
tolerance: 0.5%

## What is the reluctance of a {g} mm air gap across {A} cm²?

::: right
Right. $\frac{g}{\mu_0A}$ = {answer}.
:::

::: misses
- [any] Not yet. Air has $\mu_r = 1$.
:::
:::

::: check
given: N = 50 | 200; R = 1 | 5
answer: N^2/(R*1e6)*1000
unit: mH
tolerance: 0.5%

## A coil of {N} turns sits on a magnetic circuit with a total reluctance of {R} × 10⁶ A/Wb. What is its inductance?

::: right
Right. $L = N^2/\mathcal R$ = {answer}.
:::

::: misses
- [N/(R*1e6)*1000] Inductance goes as $N^2$.
- [any] Not yet. $L = N^2/\mathcal R$.
:::
:::

::: check
given: N = 50 | 200; I = 0.5 | 2; R = 2 | 5; A = 1 | 2
answer: N*I/(R*1e6)/(A*1e-4)
unit: T
tolerance: 0.5%

## A coil of {N} turns carries {I} A on a circuit of reluctance {R} × 10⁶ A/Wb and {A} cm² cross-section. What is the flux density in the core?

::: right
Right. $\Phi = NI/\mathcal R$, then $B = \Phi/A$ = {answer}.
:::

::: misses
- [N*I/(R*1e6)] That's the flux; divide by the area.
- [any] Not yet. MMF over reluctance gives flux.
:::
:::

::: check
given: l = 10 | 20; ur = 1000 | 4000; g = 0.3 | 1
answer: 100*(g/1000)/((l/100)/ur + g/1000)
tolerance: 0.5%

## A core with a {l} cm path and $\mu_r$ = {ur} has a {g} mm gap. What percentage of the reluctance is in the gap?

::: right
Right. $\frac{g}{l/\mu_r + g}$ = {answer}%.
:::

::: misses
- [100*(g/1000)/((l/100) + g/1000)] Divide the core's length by $\mu_r$ before comparing.
- [any] Not yet. Compare $g$ with $l/\mu_r$.
:::
:::

::: check
given: N = 100 | 300; R = 1 | 4; k = 2 | 3
answer: k^2
tolerance: 0.5%

## A coil's turns are multiplied by {k} on the same core. By what factor does its inductance change?

::: right
Right. $L \propto N^2$: {answer}.
:::

::: misses
- [k] Both the MMF and the flux linkage grow with $N$.
- [any] Not yet. $L = N^2/\mathcal R$.
:::
:::

::: explain
## Why does cutting an air gap make an inductor's value more stable?

::: model
An inductor's value is $N^2$ over the total reluctance of its flux path. The core's reluctance depends on its permeability, which varies a lot with temperature, with the current flowing, and from one core to the next. An air gap adds a reluctance that depends only on its length and area, and because air's permeability is thousands of times lower, even a thin gap can outweigh the whole core. Then the total reluctance, and the inductance, depend mostly on the gap, and the core's wandering permeability hardly matters.
:::
:::

::: practice

::: check
given: N = 100 | 500; I = 0.2 | 1
answer: N*I
unit: A
tolerance: 0.5%

## A coil of {N} turns carries {I} A. What magnetomotive force does it produce, in ampere-turns?

::: misses
- [any] $NI$.
:::
:::

::: check
given: R1 = 1 | 3; R2 = 2 | 4
answer: R1 + R2
unit: MA/Wb
tolerance: 0.5%

## A core section of {R1} MA/Wb and a gap of {R2} MA/Wb carry the same flux. What is the total reluctance?

::: misses
- [any] Series reluctances add.
:::
:::

::: check
given: B = 0.2 | 1.2; A = 1 | 4
answer: B*A*1e-4*1e6
unit: µWb
tolerance: 0.5%

## A core of {A} cm² carries {B} T. What flux is that?

::: misses
- [any] $\Phi = BA$.
:::
:::
:::