title: Magnetic materials and hysteresis
heading: Why iron makes fields stronger, and remembers them
eyebrow: B5 · Lesson 10 · Magnetic materials and hysteresis
xp: 40
---

::: hook
Put an iron core inside a coil and its field jumps by a factor of a thousand or more. Turn the current off, and some iron stays magnetized: it remembers. That memory is a nuisance in a transformer, where the core is pushed back and forth fifty or sixty times a second and wastes energy each time, and the whole point in a permanent magnet or a hard drive. The difference lies in one curve, the hysteresis loop.

::: play
- The curve plots the core's field $B$ against the magnetizing field $H$ from the coil, as $H$ sweeps back and forth.
- Shrink the coercivity: that's a soft material, like transformer steel. Widen it: a hard material, like a permanent magnet.
- Where does the curve cross $H = 0$? That's the field the material keeps with no current: its remanence.
:::
:::

```sim plot
view: complex
range: 2
axes: H, B
slider: Hc = 0.02..1 step 0.02 = 0.3
slider: Hm = 0.5..2 step 0.1 = 1.5
curve: Hm*cos(u) + j*tanh((Hm*cos(u) + Hc*sign(sin(u)))/0.25) | over: u = 0..2*pi
dot: 0 + j*tanh(Hc/0.25) | label: remanence
dot: -Hc | label: coercivity
readout: loop area (energy lost per cycle, relative) = 4*Hc*tanh(Hm/0.25)
```

::: predict
## A transformer core is magnetized back and forth 60 times a second. What kind of core material should it have?

- [x] A soft one: a narrow loop
- [ ] A hard one: a wide loop
- [ ] It doesn't matter
- [ ] No core at all

::: reveal
A soft one. The area inside the hysteresis loop is energy lost as heat on every cycle. A wide loop at 60 Hz would cook the core. Transformer steels and ferrites are made to have the narrowest possible loops. Permanent magnets are the opposite: you want a wide loop, so they hold on to their magnetization against anything that tries to remove it.
:::
:::

::: nameit
## Magnetic materials

**H and B.** In a material, it's useful to separate the field you apply from what the material adds. The coil sets the **magnetizing field** $H$, in amperes per meter (for a long solenoid, $H = nI$). The material responds, and the total field is

$$B = \mu H = \mu_r\mu_0H$$

where μᵣ is the **relative permeability**. In vacuum μᵣ = 1.

**Three kinds of response.**

- **Diamagnetic** materials (copper, water, bismuth) push back very slightly: μᵣ just below 1.
- **Paramagnetic** materials (aluminum, oxygen) line up very slightly with the field: μᵣ just above 1.
- **Ferromagnetic** materials (iron, nickel, cobalt, many alloys and ferrites) line up enormously. Their atoms' magnetic moments are grouped into **domains**, regions already magnetized in one direction. A field makes domains aligned with it grow at the expense of the others. μᵣ runs from about 100 to over 100,000.

**Saturation.** Once nearly all the domains are aligned, there's nothing more to align: B levels off. Silicon steel saturates around 1.5 to 2 T, ferrites around 0.3 to 0.5 T. Inductors and transformers must be designed to stay below saturation, or their inductance collapses.

**Hysteresis.** Domain walls stick on defects, so the material's state depends on its history. Sweep $H$ up and down and $B$ traces a loop. Where the loop crosses $H = 0$ is the **remanence** (field left with no current); where it crosses $B = 0$ is the **coercivity** (reverse field needed to wipe it out). The loop's area is energy lost as heat per cycle per unit volume.

| Material | Use | Loop |
|---|---|---|
| silicon steel, ferrite | transformers, inductors | narrow (soft) |
| neodymium iron boron | permanent magnets, motors | very wide (hard) |
| magnetic recording media | data storage | wide, square |
:::

::: example
## The 1.26 mT solenoid of lesson 8 is filled with iron of $\mu_r$ = 1000. About what field results?

::: solution
1. **Field with the iron.**
   $$\begin{aligned} B &= \mu_r\mu_0nI \\ &= 1000 \times 1.26\ \text{mT} \\ &= 1.26\ \text{T} \end{aligned}$$
2. **Saturation.** In practice iron saturates around 1.5 to 2 T, so pushing the current much higher would gain little.

**Answer:** about 1.26 T, a thousand times more than with an air core.
:::
:::

::: example
## A transformer core of $10^{-4}$ m³ loses 100 J/m³ per cycle to hysteresis. How much power does that waste at 50 Hz?

::: solution
1. **Energy lost per cycle.** Each cycle around the loop loses its area in energy density:
   $$100 \times 10^{-4} = 0.01\ \text{J}$$
2. **Power at 50 Hz.** That happens 50 times a second:
   $$0.01\ \text{J} \times 50\ \text{s}^{-1} = 0.5\ \text{W}$$
3. **Why soft cores.** That's why transformer cores use soft materials with thin loops.

**Answer:** hysteresis wastes 0.5 W.
:::
:::

::: check
given: mur = 100 | 1000 | 5000; n = 500 | 1000; I = 0.1 | 0.5
answer: mur*4*pi*1e-7*n*I
unit: T
tolerance: 0.5%

## A long solenoid with {n} turns per meter carries {I} A around a core with μᵣ = {mur}. What is B in the core (if it isn't saturated)?

::: right
Right. $B = \mu_r\mu_0nI$ = {answer}.
:::

::: misses
- [4*pi*1e-7*n*I] That's without the core. Multiply by μᵣ.
- [any] Not yet. $B = \mu_r\mu_0nI$.
:::
:::

::: check
given: n = 500..2000 step 500; I = 1..5 int
answer: n*I
unit: A/m
tolerance: 0.5%

## A long solenoid has {n} turns per meter carrying {I} A. What is H inside it?

::: right
Right. $H = nI$ = {answer}, whatever the core.
:::

::: misses
- [4*pi*1e-7*n*I] That's B in vacuum. H is just $nI$.
- [any] Not yet. $H = nI$.
:::
:::

::: check
given: B = 1 | 1.5 | 2; H = 100 | 500 | 1000
answer: B/(4*pi*1e-7*H)
tolerance: 1%

## A core shows {B} T with H = {H} A/m. What is its relative permeability there?

::: right
Right. $\mu_r = B/(\mu_0H)$ = {answer}.
:::

::: misses
- [B/H] Divide by $\mu_0$ too: μᵣ is relative to vacuum.
- [any] Not yet. $\mu_r = B/(\mu_0H)$.
:::
:::

::: check
kind: match

## Match each material with its kind of response.

- iron :: ferromagnetic
- copper :: diamagnetic
- aluminum :: paramagnetic
- neodymium magnet :: hard ferromagnet

::: right
Right. Only ferromagnets respond strongly; the other two are tiny effects.
:::
:::

::: check
kind: choice

## A transformer core is driven so hard that it saturates at the peaks. What happens?

- [ ] Its inductance rises
- [x] Its inductance collapses at the peaks, and the current spikes
- [ ] It becomes a permanent magnet
- [ ] Nothing: saturation is harmless

::: right
Right. Once the core can't add more field, extra current gets little extra flux, so the inductance drops and the current surges.
:::

::: misses
- [1] It falls: the core stops helping.
- [3] A soft core keeps little magnetization afterward.
- [4] The current spikes can overheat windings and trip protection.
:::
:::

::: check
given: Bs = 0.3 | 0.5 | 1.5; mr = 1000 | 2000 | 5000; n = 1000 | 5000
answer: Bs/(4*pi*1e-7*mr*n)*1e3
unit: mA
tolerance: 0.5%

## A solenoid with {n} turns per meter is wound on a core of relative permeability {mr} that saturates at {Bs} T. What current saturates it?

::: right
Right. $I = B_s/(\mu_0\mu_rn)$ = {answer}: a high-permeability core saturates at small currents.
:::

::: misses
- [Bs/(4*pi*1e-7*n)*1e3] The core multiplies the field by $\mu_r$.
- [any] Not yet. $B = \mu_0\mu_rnI$.
:::
:::

::: explain
## Why does the area inside a hysteresis loop represent energy lost?

::: model
Driving the material around its loop means pushing domain walls back and forth against the defects that pin them, and that friction-like process turns energy into heat. Going up one side of the loop you put energy into magnetizing the material; coming down the other side you get less back, because the material holds on to its magnetization. The difference, per cycle and per unit volume, is the area enclosed by the B–H curve.
:::
:::

::: practice

::: check
given: mur = 1000 | 2000; B0 = 1 | 2
answer: mur*B0
unit: mT
tolerance: 0.5%

## An air-core coil makes {B0} mT. With a core of μᵣ = {mur} (unsaturated), what field?

::: misses
- [B0] The core multiplies the field by μᵣ.
- [any] $B = \mu_rB_0$.
:::
:::

::: check
kind: choice

## A permanent magnet needs what kind of hysteresis loop?

- [ ] Narrow, so it's efficient
- [x] Wide, so it resists being demagnetized
- [ ] None at all
- [ ] It doesn't matter

::: right
Right. High coercivity means a strong reverse field is needed to demagnetize it.
:::

::: misses
- [1] A narrow loop is easily demagnetized.
- [3] Without hysteresis it wouldn't stay magnetized.
- [4] The loop's width is exactly what makes it permanent.
:::
:::

::: check
given: H = 100..1000 step 100; mur = 1
answer: 4*pi*1e-7*H*1e6
unit: µT
tolerance: 0.5%

## In air (μᵣ = 1), what field B corresponds to H = {H} A/m, in µT?

::: misses
- [H] Multiply by $\mu_0$.
- [any] $B = \mu_0H$.
:::
:::
:::