B613 of 15
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B6 · Lesson 13 · Back-EMF in motors

A spinning motor is also a generator

Switch on a drill and the lights flicker: at the instant it starts, the motor draws a huge current. A second later it's spinning and drawing much less, even though nothing about its supply has changed. The reason is that a spinning motor is also a generator. Its coils turning in the magnet's field generate a voltage that opposes the supply, the back-EMF, growing with speed, and the current is only what the difference can push through the windings' resistance.

Play

  • A DC motor with winding resistance R and back-EMF constant k runs from V. The graph shows its current and torque as its speed rises.
  • At zero speed (just starting, or stalled), what limits the current?
  • Find the no-load speed, where the current falls to zero. How does it depend on V and k?

Predict

A motor jams and stops turning while still powered. What happens to its current?

Name it

The DC motor as a circuit

Back-EMF. As the armature spins at ω, its coils cut through the field and generate an EMF (lesson 4), proportional to the speed:

ℰback=kω

It opposes the supply. Around the motor's circuit:

V=IR+kωI=V−kωR

Torque. The same constant sets the torque per amp: τ=kI (in SI units the two constants are identical, which follows from energy conservation). So torque is largest at zero speed and falls in a straight line, reaching zero at the no-load speed ω0=V/k, where the back-EMF equals the supply.

Power flow. Multiply the circuit equation by I:

VI=I2R+kωI=I2R+τω

Electrical power in = heat in the windings + mechanical power out. At low speed most of the input becomes heat; near full speed most becomes motion. This is the torque–speed line of B1.29, now explained.

Consequences.

  • Inrush current. A motor starting from rest draws V/R, many times its running current. Large motors use soft starters or variable-speed drives to bring the voltage up gradually.
  • Speed control. Lowering the supply voltage lowers the no-load speed in proportion: that's how a PWM motor driver controls speed.
  • Regenerative braking. Drive the motor faster than its no-load speed (as when an electric car coasts downhill) and the back-EMF exceeds the supply: current flows backward and the motor becomes a generator, returning energy to the battery.
  • Sensing. Measuring the back-EMF tells a brushless motor controller how fast and where the rotor is, with no sensor.

Worked example

A 12 V motor has a 1 Ω armature and k = 0.05 V·s/rad. Find its stall current and no-load speed.

Show the solution
  1. Stall current. Stalled, there's no back-EMF: I=121=12A
  2. No-load speed. With no load the current falls to nearly zero, which happens when kω=V: ω=120.05=240rad/s about 2290 rpm.

Answer the stall current is 12 A and the no-load speed is 240 rad/s, about 2290 rpm.

Worked example

The same motor runs at 200 rad/s. Find its current, torque, mechanical output and efficiency.

Show the solution
  1. Back-EMF. 0.05×200=10V
  2. Current. I=12−101=2A
  3. Torque. τ=kI=0.1N·m
  4. Power out and in. Pout=0.1×200=20WPin=12×2=24W
  5. Efficiency. 2024=83% with the other 4 W heating the armature.

Answer the motor draws 2 A and makes 0.1 N·m, putting out 20 W of the 24 W it takes in, 83% efficient.

Check

A 12 V DC motor has 0.5 Ω winding resistance. What current does it draw when stalled?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A 12 V motor (0.5 Ω, k = 0.05 V·s/rad) runs at 100 rad/s. What current does it draw?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

What is the no-load speed of a 12 V motor with k = 0.02 V·s/rad, in rpm?

Check

A 12 V motor with 1 Ω windings draws 1 A while running. How much mechanical power does it deliver (ignoring friction)?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

An electric car rolls downhill fast enough that its motor turns faster than its no-load speed. What happens?

Check

A DC motor has armature resistance 0.5 Ω and back-EMF constant 0.05 V·s/rad, on a 24 V supply.

(a)

What current does it draw at 300 rad/s?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What current does it draw when stalled?

Explain why

Why does a DC motor draw much more current when starting than when running at speed?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.