title: Coupling, leakage and wireless power
heading: How much flux two coils share, and how resonance makes up for it
eyebrow: B6 · Lesson 11 · Coupling and wireless power
xp: 40
---

::: hook
A transformer's coils share nearly all their flux through an iron core. A phone lying on a charging pad shares only a small part of the pad's flux, through a few millimeters of air, and an RFID tag a few centimeters from a reader shares almost none. Yet both still work. The fraction of flux two coils share, their coupling coefficient, sets how much one can do to the other, and resonating both coils with capacitors lets a weakly coupled pair still pass power efficiently. That's the physics behind wireless charging, contactless cards and the leakage that every transformer designer fights.
:::

::: play
- Two coils are each tuned to resonance and have quality factor $Q$. The curve is the best possible efficiency of power transfer between them, against their coupling coefficient $k$ (log scale).
- Efficiency depends only on the product $kQ$: high-Q coils can pass power efficiently even when barely coupled.
- With Q = 100, how small can $k$ get before efficiency falls below 50%?
:::
:::

```sim plot
view: graph
x: k = 0.001..1 log
y: n = 0..100 %
slider: Q = 10..500 step 10 = 100
slider: k0 = 0.001..1 = 0.1 log
plot: 100*(k*Q)^2/(1 + sqrt(1 + (k*Q)^2))^2 | label: best efficiency
marker: x = k0 | label: k
readout: kQ = k0*Q | digits: 3
readout: best efficiency, % = 100*(k0*Q)^2/(1 + sqrt(1 + (k0*Q)^2))^2 | digits: 3
```

::: predict
## Two small coils sit coaxially, 10 cm apart, each 2 cm in radius. How does their mutual inductance change if they're moved to 20 cm apart?

- [ ] It halves
- [ ] It falls to a quarter
- [x] It falls to an eighth
- [ ] It doesn't change

::: reveal
It falls to an eighth. Far from a coil its field is a dipole field, which falls as $1/d^3$, so the flux it sends through the second coil, and the mutual inductance, fall as $1/d^3$ too. That steep drop is why charging pads need the phone right on top of them.
:::
:::

::: nameit
## Coupling coefficient

Two coils with self-inductances $L_1$ and $L_2$ and mutual inductance $M$ (B6.10) have **coupling coefficient**

$$k = \frac{M}{\sqrt{L_1L_2}}, \qquad 0 \le k \le 1$$

the fraction of flux they share. Cored transformers reach $k$ = 0.99 and more; air-cored coils a few millimeters apart, 0.3 to 0.8; coils several radii apart, under 0.01.

**Leakage.** Flux from one coil that misses the other acts like an extra inductance in series: about $(1 - k^2)L_1$, the **leakage inductance**. It limits how fast a transformer can pass current changes and causes voltage spikes in switching converters.

## Coils at a distance

For two coaxial loops of radii $r_1$ and $r_2$, far apart compared with their size ($d \gg r$), coil 1's dipole field threads coil 2:

$$M \approx \frac{\mu_0\pi r_1^2r_2^2}{2d^3}$$

times $N_1N_2$ for multi-turn coils. A current $I_1$ at angular frequency ω induces $\omega MI_1$ in coil 2.

## Resonant power transfer

Tuning both coils with capacitors to the same frequency cancels their reactance, so even a small induced voltage drives a useful current. The best achievable efficiency depends only on $k$ and the coils' quality factors:

$$\eta_\text{max} = \frac{x^2}{\left(1 + \sqrt{1 + x^2}\right)^2}, \qquad x = k\sqrt{Q_1Q_2}$$

With $x = 1$ it's 17%; with $x = 10$, 82%. Qi chargers work near 100 to 200 kHz with $k$ around 0.3 to 0.7; NFC and RFID tags at 13.56 MHz work at much lower $k$, carrying signals and tiny amounts of power.
:::

::: example
## Two 10-turn coils of radius 2 cm sit coaxially 10 cm apart. Estimate their mutual inductance, and the voltage induced in one by 1 A at 150 kHz in the other.

::: solution
1. **Mutual inductance.**
   $$\begin{aligned} M &\approx N^2\frac{\mu_0\pi r^4}{2d^3} \\ &= 100 \times \frac{4\pi \times 10^{-7} \times \pi \times (0.02)^4}{2 \times 0.1^3} \\ &= 32\ \text{nH} \end{aligned}$$
2. **Induced voltage.**
   $$\begin{aligned} V &= \omega MI \\ &= 2\pi \times 150\,000 \\ &\quad \times 32 \times 10^{-9} \times 1 \\ &= 30\ \text{mV} \end{aligned}$$
3. **Is that useful?** At this distance, only resonance makes the link useful.

**Answer:** the mutual inductance is about 32 nH, and 1 A at 150 kHz induces about 30 mV.
:::
:::

::: example
## Coils with $Q$ = 100 each are coupled with $k$ = 0.1, and then $k$ = 0.01. What is the best efficiency in each case?

::: solution
1. **Figure of merit.** With $x = kQ$, the two cases have $x = 10$ and $x = 1$.
2. **Best efficiency at k = 0.1.**
   $$\begin{aligned} \eta &= \frac{100}{(1 + \sqrt{101})^2} \\ &= 82\% \end{aligned}$$
3. **Best efficiency at k = 0.01.**
   $$\begin{aligned} \eta &= \frac{1}{(1 + \sqrt2)^2} \\ &= 17\% \end{aligned}$$
4. **Compare.** Ten times weaker coupling costs a great deal, which is why pads align the phone carefully.

**Answer:** the best efficiency is 82% at k = 0.1 and 17% at k = 0.01.
:::
:::

::: check
given: M = 10 | 50; L1 = 100 | 200; L2 = 50 | 150
answer: M/sqrt(L1*L2)
tolerance: 0.5%

## Two coils have $L_1$ = {L1} µH, $L_2$ = {L2} µH and $M$ = {M} µH. What is their coupling coefficient?

::: right
Right. $\frac{M}{\sqrt{L_1L_2}}$ = {answer}.
:::

::: misses
- [M/((L1 + L2)/2)] Use the geometric mean of the inductances.
- [M/L1] Divide by $\sqrt{L_1L_2}$.
- [any] Not yet. $k = M/\sqrt{L_1L_2}$.
:::
:::

::: check
given: k = 0.95 | 0.99; L = 100 | 1000
answer: (1 - k^2)*L
unit: µH
tolerance: 0.5%

## A transformer winding of {L} µH has coupling coefficient {k}. About what leakage inductance does it show?

::: right
Right. $(1 - k^2)L$ = {answer}.
:::

::: misses
- [(1 - k)*L] The leakage is $(1 - k^2)L$.
- [any] Not yet. $(1 - k^2)L_1$.
:::
:::

::: check
given: N = 5 | 20; r = 1 | 3; d = 8 | 15
answer: N^2*4*pi*1e-7*pi*(r/100)^4/(2*(d/100)^3)*1e9
unit: nH
tolerance: 0.5%

## Two {N}-turn coils of radius {r} cm sit coaxially {d} cm apart. Estimate their mutual inductance.

::: right
Right. $N^2\frac{\mu_0\pi r^4}{2d^3}$ = {answer}.
:::

::: misses
- [N*4*pi*1e-7*pi*(r/100)^4/(2*(d/100)^3)*1e9] Both coils' turns count: $N_1N_2$.
- [N^2*4*pi*1e-7*pi*(r/100)^4/(2*(d/100)^2)*1e9] The dipole field falls as $1/d^3$.
- [any] Not yet. Dipole field of coil 1 through coil 2.
:::
:::

::: check
given: M = 10 | 100; I = 0.5 | 2; f = 100 | 500
answer: 2*pi*f*1000*M*1e-9*I*1000
unit: mV
tolerance: 0.5%

## A {I} A current at {f} kHz flows in one coil; the mutual inductance to another is {M} nH. What voltage does the other coil pick up (amplitude)?

::: right
Right. $\omega MI$ = {answer}.
:::

::: misses
- [f*1000*M*1e-9*I*1000] Use the angular frequency, $2\pi f$.
- [any] Not yet. $V = M\frac{di}{dt}$, amplitude $\omega MI$.
:::
:::

::: check
given: k = 0.02 | 0.1 | 0.3; Q = 30 | 100
answer: 100*(k*Q)^2/(1 + sqrt(1 + (k*Q)^2))^2
tolerance: 0.5%

## Two resonant coils, each with Q = {Q}, are coupled with $k$ = {k}. What is the best achievable efficiency, in percent?

::: right
Right. With $x = kQ$, $\frac{x^2}{(1 + \sqrt{1 + x^2})^2}$ = {answer}%.
:::

::: misses
- [100*k] Resonance makes up for weak coupling: use $kQ$.
- [any] Not yet. Compute $x = kQ$ first.
:::
:::

::: check
given: d1 = 5 | 10; d2 = 15 | 30
answer: (d1/d2)^3
tolerance: 0.5%

## Two coils are moved from {d1} cm to {d2} cm apart, both far compared with their size. By what factor does their mutual inductance change?

::: right
Right. $M \propto 1/d^3$: {answer}.
:::

::: misses
- [(d1/d2)^2] The dipole field falls as $1/d^3$.
- [any] Not yet. $(d_1/d_2)^3$.
:::
:::

::: explain
## How does tuning both coils to resonance let weakly coupled coils transfer power efficiently?

::: model
With weak coupling, only a small voltage is induced in the receiving coil, and on its own the coil's inductive reactance would let only a tiny current flow. Adding a capacitor tuned to cancel that reactance leaves only the coil's small resistance, so the small voltage drives a large current, magnified by the coil's Q. The same happens on the transmitting side. The power transferred grows with $k^2Q_1Q_2$ compared with the power lost in the coils' resistances, so high Q can make up for low $k$.
:::
:::

::: practice

::: check
given: k = 0.1 | 0.5; L1 = 10 | 40; L2 = 10 | 40
answer: k*sqrt(L1*L2)
unit: µH
tolerance: 0.5%

## Coils of {L1} µH and {L2} µH have $k$ = {k}. What is their mutual inductance?

::: misses
- [any] $M = k\sqrt{L_1L_2}$.
:::
:::

::: check
given: x = 1 | 3 | 10
answer: 100*x^2/(1 + sqrt(1 + x^2))^2
tolerance: 0.5%

## What is the best efficiency when $k\sqrt{Q_1Q_2}$ = {x}, in percent?

::: misses
- [any] $\frac{x^2}{(1 + \sqrt{1 + x^2})^2}$.
:::
:::

::: check
given: k = 0.9 | 0.95 | 0.98 | 0.99 | 0.995 | 0.999
answer: 100*(1 - k^2)
tolerance: 0.5%

## A transformer's coupling coefficient is {k}. What percentage of a winding's inductance appears as leakage?

::: misses
- [any] $(1 - k^2)$.
:::
:::
:::