B6 · Lesson 14 · Induction lab
Flux, mutual inductance, transients, eddy losses and wireless power, computed
Induction is where magnetism turns into circuit elements: mutual inductance between two loops, the voltage a switching current induces in a nearby trace, the loss in a transformer core, the efficiency of a phone charger's coils. Few of these have tidy formulas. In this lab you'll compute flux by integration, mutual inductance from Neumann's double sum around two loops, an RL transient by stepping, eddy losses by averaging the induced current across a lamination, and the best load for a pair of coupled coils.
- Two resonant coils, each with quality factor Q, are coupled with coefficient k. The curve is the best efficiency they can reach, with the load chosen to maximize it, against k.
- Efficiency depends only on the product : weak coupling can be made up for with high Q, which is how a charging pad works across a few millimeters of plastic.
- The readout gives the best efficiency at k = 0.1.
Predict
A 10 A current in a long trace switches off in 10 µs. A rectangular loop 5 cm by 10 cm lies beside it, its near side 2 cm away. Roughly what EMF does the loop pick up?
About 25 mV. The mutual inductance is nH, and A/s, so the EMF is mV. That's how a fast edge on one trace puts a glitch on a neighboring circuit, and why fast loops are kept small and close to their return paths.
Name it
Flux by integration
The flux through a surface is . For a rectangle beside a long wire, B falls as across it, so split the rectangle into strips parallel to the wire: .
Neumann's formula
The mutual inductance of two loops is a double sum over their pieces,
symmetric in the two loops, which is why . For two coaxial circles it has an exact answer in elliptic integrals, which makes a good test of a numerical sum. Far apart, it falls to the dipole result .
Transients by stepping
An RL circuit obeys . Euler's method, , approaches the exact as the step shrinks, with error proportional to h.
Eddy-current loss
In a lamination of thickness t, a changing field induces a current density , growing with the distance x from the middle. Averaging over the thickness and a cycle gives per cubic meter: thin laminations cut the loss as .
Wireless power
Two resonant coils with quality factors , and coupling k, the receiver's load being a times its coil resistance, transfer power with efficiency , . The best load is , giving .
Worked example
Two coaxial loops of radius 5 cm sit 50 cm apart. How does the exact mutual inductance compare with the dipole approximation?
Show the solution
- Dipole approximation.
- Exact value. Neumann's double sum, or the elliptic-integral formula, gives
- Compare. At ten radii the dipole picture is 3% high.
- Up close. There it fails completely: at 2 cm apart, loops of 5 and 3 cm radius have M = 28.9 nH, nowhere near what the dipole formula says.
Answer the dipole approximation gives 98.7 pH against the exact 95.8 pH, 3% high at ten radii.
Worked example
A transformer core of silicon steel (ρ = 4.7 × 10⁻⁷ Ω·m) is built of 0.35 mm laminations and runs at 1.5 T, 50 Hz. What is its eddy-current loss?
Show the solution
- Loss per cubic meter.
- Loss per kilogram. At 7650 kg/m³,
- A solid core. A solid core of the same steel, say 10 cm thick, would by the same formula lose about 80 000 times more: In practice that means the field never gets into it at all: the skin effect takes over.
- What laminations do. Insulated from each other, they break the eddy paths into thin layers.
Answer the eddy-current loss is 2412 W/m³, or 0.32 W/kg.
Worked example
Two charging coils have Q = 100 each. What is the best efficiency at k = 0.1, and at k = 0.01?
Show the solution
- Figure of merit at k = 0.1.
- Best load ratio.
- Best efficiency at k = 0.1.
- Best efficiency at k = 0.01. Now U = 1, so
- What it means. The efficiency stays high while and collapses once it falls below 1, which sets how far apart coils can be. Raising Q tenfold restores the efficiency at a tenth of the coupling, if the coils can be kept in tune.
Answer the best efficiency is 81.9% at k = 0.1 and 17.2% at k = 0.01.
Check
Step 1. Write flux_wire(I, d, a, b, n) that integrates the field of a long straight wire carrying I over a rectangle beside it (near side d from the wire, extending a away from it and b along it), in n strips with the midpoint rule.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Step 2. Write neumann(R1, R2, z, n) for two coaxial circular loops of radii R1 and R2 a distance z apart: split each into n pieces and evaluate with NumPy arrays.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Step 3. Write rl_step(V, R, L, T, n) that steps from i = 0 with n Euler steps up to time T and returns the current.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Step 4. Write eddy_loss(f, B, t, rho, nx, nt) that averages , with , over nx midpoints across a lamination of thickness t (x from to ) and nt midpoints in one period, returning the loss in W/m³.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Step 5. Write wpt_efficiency(k, Q1, Q2, a) using with , and best_load(k, Q1, Q2) that tries load ratios a from 0.01 to 50 in 5000 steps and returns (a, efficiency) for the best.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Two charging coils, each with Q = 50, are coupled with k = 0.05.
(a)
What load, in multiples of the receiver coil's resistance, gives the best efficiency?
(b)
What is that best efficiency?
Check
A rectangular loop's near side is 1 cm from a long wire; it extends 2 cm away from the wire and 20 cm along it. What is the mutual inductance?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Explain why
Why does making a transformer's laminations thinner reduce its eddy-current loss so sharply?
The changing flux induces an EMF around every closed path in the steel, and the larger the path, the more flux it encloses and the bigger the EMF. In a lamination the largest paths are limited by the thickness, so the induced electric field, and the current density, grow in proportion to the distance from the lamination's middle, reaching a maximum proportional to the thickness. The heat goes as the current density squared, so the loss per unit volume goes as the thickness squared: halving the thickness quarters the loss. The insulation between laminations is what stops the currents from finding the larger paths through the whole core.
Practice
Keep practicing
4 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.