title: Mutual inductance and transformers
heading: Two coils sharing one magnetic field
eyebrow: B6 · Lesson 10 · Mutual inductance and transformers
xp: 50
---

::: hook
Wind two coils on the same iron core. Alternating current in the first makes a changing flux in the core, and that same flux threads the second coil, inducing a voltage there, with no electrical connection between them. Change the number of turns and you change the voltage: up for transmission, down for your phone charger. Transformers are why the grid uses AC, and why a power supply can be safely isolated from the mains.

::: play
- A sine wave drives the primary coil of $N_1$ turns; the secondary has $N_2$ turns. The graph shows both voltages.
- Make $N_2$ larger than $N_1$. What happens to the secondary voltage? Make it smaller.
- The readout gives the secondary current for a load of $R_L$. How does it compare with the primary current?
:::
:::

```sim plot
view: graph
x: t = 0..40 ms
y: v = -400..400 V
slider: N1 = 100..1000 step 50 = 500
slider: N2 = 10..2000 step 10 = 50
slider: RL = 1..100 step 1 = 10 Ω
plot: 325*sin(2*pi*50*t/1000) | label: primary (230 V RMS)
plot: 325*N2/N1*sin(2*pi*50*t/1000) | color: ch2 | label: secondary
readout: secondary RMS = 230*N2/N1 V
readout: secondary current = 230*N2/N1/RL A
readout: primary current = (230*N2/N1/RL)*N2/N1 A
```

::: predict
## A transformer steps 230 V down to 23 V. If the secondary delivers 2 A, roughly what current does the primary draw (ignoring losses)?

- [ ] 2 A
- [ ] 20 A
- [x] 0.2 A
- [ ] 0.02 A

::: reveal
0.2 A. An ideal transformer neither makes nor loses power, so the 46 W going out must come in: 230 V × 0.2 A. The voltage steps down by 10 and the current steps up by 10. That's how transmission works: step up the voltage to step down the current, cutting the $I^2R$ loss in the lines (B4.8).
:::
:::

::: nameit
## Mutual inductance

**Coupled coils.** Current $i_1$ in one coil makes flux that partly threads a second coil. The **mutual inductance** $M$ says how much: the voltage induced in coil 2 is

$$v_2 = M\frac{di_1}{dt}$$

and it works the same way back, from coil 2 to coil 1. How much of one coil's flux reaches the other is the **coupling coefficient** $k$, with $M = k\sqrt{L_1L_2}$ and $0 \le k \le 1$. Coils on a shared iron core reach $k > 0.99$; coils that just sit near each other might have $k$ of a few percent.

## The ideal transformer

With perfect coupling, the same changing flux $\Phi$ threads every turn of both coils, so each turn has the same voltage $d\Phi/dt$ induced in it:

$$\frac{V_2}{V_1} = \frac{N_2}{N_1}$$

With no losses, power in equals power out, $V_1I_1 = V_2I_2$, so

$$\frac{I_2}{I_1} = \frac{N_1}{N_2}$$

A load $R_L$ on the secondary looks, from the primary, like a resistance $(N_1/N_2)^2R_L$. Audio output transformers and RF baluns use this **impedance transformation** to match a load to a source.

**Only AC.** A transformer needs a *changing* flux. Feed DC into its primary and nothing appears at the secondary (after the switch-on transient), while the primary current climbs until something overheats.

**Real transformers** lose a few percent: resistance in the windings (copper loss), hysteresis and eddy currents in the core (iron loss, kept down by laminating the core into thin insulated sheets), and imperfect coupling (leakage inductance). Large power transformers are over 99% efficient.

**Isolation.** The secondary has no electrical connection to the primary, only a magnetic one. That's what makes a mains adapter safe to touch at its output.
:::

::: example
## A transformer steps 230 V down to 12 V. What turns ratio does it need, and what primary current flows when the secondary supplies 2 A?

::: solution
1. **Turns ratio.**
   $$\begin{aligned} \frac{N_p}{N_s} &= \frac{230}{12} \\ &= 19.2 \end{aligned}$$
2. **Primary current.** Power in equals power out for an ideal transformer:
   $$\begin{aligned} I_p &= 2 \times \frac{12}{230} \\ &= 0.10\ \text{A} \end{aligned}$$

**Answer:** the transformer needs a turns ratio of 19.2, and 0.10 A flows in the primary.
:::
:::

::: example
## An 8 Ω speaker is driven through a 10:1 transformer. What resistance does the amplifier see?

::: solution
1. **Reflected resistance.**
   $$\begin{aligned} R' &= 8 \times 10^2 \\ &= 800\ \Omega \end{aligned}$$
2. **Why the square.** Transformers match loads to sources by the square of their turns ratio.

**Answer:** the amplifier sees 800 Ω.
:::
:::

::: check
given: V1 = 120 | 230 | 240; N1 = 100..1000 step 100; N2 = 10..90 step 10
answer: V1*N2/N1
unit: V
tolerance: 0.5%

## A transformer with {N1} primary turns and {N2} secondary turns is fed {V1} V. What does the secondary give?

::: right
Right. $V_2 = V_1N_2/N_1$ = {answer}.
:::

::: misses
- [V1*N1/N2] Upside down: fewer secondary turns means lower voltage.
- [any] Not yet. $V_2/V_1 = N_2/N_1$.
:::
:::

::: check
given: V1 = 230 | 120; V2 = 5 | 12 | 24; I2 = 1 | 2 | 5
answer: I2*V2/V1
unit: A
tolerance: 0.5%

## An ideal transformer steps {V1} V down to {V2} V and delivers {I2} A. What current does its primary draw?

::: right
Right. Power in equals power out: $I_1 = I_2V_2/V_1$ = {answer}.
:::

::: misses
- [I2] The current changes by the inverse of the voltage ratio.
- [I2*V1/V2] Stepping voltage down steps current up on the secondary, so the primary current is smaller.
- [any] Not yet. $V_1I_1 = V_2I_2$.
:::
:::

::: check
given: n = 2 | 5 | 10; RL = 4 | 8 | 50
answer: n^2*RL
unit: Ω
tolerance: 0.5%

## A transformer with a turns ratio $N_1:N_2$ = {n}:1 has a {RL} Ω load on its secondary. What resistance does the primary see?

::: right
Right. $(N_1/N_2)^2R_L$ = {answer}.
:::

::: misses
- [n*RL] The resistance transforms by the square of the turns ratio.
- [RL/n^2] Going from the low-turns side to the high-turns side, resistance looks larger.
- [any] Not yet. $R_\text{seen} = (N_1/N_2)^2R_L$.
:::
:::

::: check
given: k = 0.1 | 0.5 | 0.99; L1 = 1 | 4; L2 = 9 | 16
answer: k*sqrt(L1*L2)
unit: mH
tolerance: 0.5%

## Two coils of {L1} mH and {L2} mH have a coupling coefficient of {k}. What is their mutual inductance?

::: right
Right. $M = k\sqrt{L_1L_2}$ = {answer}.
:::

::: misses
- [sqrt(L1*L2)] That's perfect coupling. Multiply by k.
- [k*(L1 + L2)/2] Use the geometric mean, $\sqrt{L_1L_2}$.
- [any] Not yet. $M = k\sqrt{L_1L_2}$.
:::
:::

::: check
kind: choice

## A transformer's primary is connected to a 12 V battery. After the first instant, what does the secondary show?

- [ ] 12 V times the turns ratio
- [x] Nothing: the flux stops changing, so nothing is induced
- [ ] A steady small voltage
- [ ] A sine wave

::: right
Right. Transformers need changing flux. DC gives a brief pulse at switch-on and then nothing.
:::

::: misses
- [1] That's for AC. A steady current makes a steady flux, which induces nothing.
- [3] Without change in flux there's no induced voltage at all.
- [4] There's no oscillation to make one.
:::
:::

::: check
kind: parts
given: Vp = 120 | 230; Np = 500 | 1000; Ns = 25 | 50 | 100; R = 4 | 8 | 16

## A transformer has {Np} primary and {Ns} secondary turns, {Vp} V on the primary and a {R} Ω load.

::: part
answer: Vp*Ns/Np
unit: V
tolerance: 0.5%

### What is the secondary voltage?

::: misses
- [Vp*Np/Ns] Voltage scales with turns: secondary over primary.
- [any] Not yet. $V_s = V_pN_s/N_p$.
:::
:::

::: part
answer: R*(Np/Ns)^2
unit: Ω
tolerance: 0.5%

### What resistance does the primary see?

::: misses
- [R*Np/Ns] Impedance scales with the turns ratio squared.
- [R*(Ns/Np)^2] Seen from the side with more turns, the load looks larger.
- [any] Not yet. $R' = R(N_p/N_s)^2$.
:::
:::

::: right
Right. That squared ratio is how transformers match a loudspeaker to an amplifier or an antenna to a line.
:::
:::

::: explain
## Why does an ideal transformer's secondary current go down when its voltage goes up?

::: model
An ideal transformer has no losses, so all the power going into the primary comes out of the secondary: $V_1I_1 = V_2I_2$. If the turns ratio raises the voltage by some factor, the current must fall by the same factor to keep the product the same. Physically, the secondary's current makes flux that opposes the primary's, and the primary draws just enough extra current to cancel it, in the ratio of the turns.
:::
:::

::: practice

::: check
given: V1 = 10 | 20; n = 10 | 20 | 50
answer: V1*n
unit: V
tolerance: 0.5%

## A step-up transformer has a turns ratio of 1:{n}. With {V1} V in, what comes out?

::: misses
- [V1/n] It's a step-up: multiply.
- [any] $V_2 = nV_1$.
:::
:::

::: check
given: V1 = 230; V2 = 5 | 9 | 12
answer: 230/V2
tolerance: 0.5%

## What turns ratio $N_1/N_2$ steps 230 V down to {V2} V?

::: misses
- [V2/230] That's $N_2/N_1$.
- [any] $N_1/N_2 = V_1/V_2$.
:::
:::

::: check
given: P = 10..100 step 10; eff = 90 | 95 | 98
answer: P*(100/eff - 1)
unit: W
tolerance: 0.5%

## A transformer delivers {P} W at {eff}% efficiency. How much power does it waste?

::: misses
- [P*(1 - eff/100)] The input is $P/\eta$; the loss is input minus output.
- [any] Loss $= P/\eta - P$.
:::
:::
:::