B827 of 29
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B8 · Lesson 27 · Project

Choose a wavelength, fiber and laser to meet a distance and a data rate

Two data centers 60 km apart need a 10 Gb/s connection, and a building needs 300 m links between floors at the same rate. Each design has to clear two separate hurdles: enough light must arrive for the receiver (the power budget), and the pulses must arrive sharp enough to tell apart (the dispersion budget). In this project you'll work through both for real designs, write a function that finds a link's reach, and use it to pick the cheapest design that meets a target.

  • The reach of a fiber link against bit rate, on log scales. The flat line is the loss limit: how far the power budget lasts. The falling line is the dispersion limit: how far before pulses spread by half a bit period.
  • The link's actual reach is the lower of the two. At low bit rates loss sets it; at high rates, dispersion does.
  • Narrow the laser's spectrum (Δλ) and watch the crossover move. Switch to 1310 nm-like numbers (higher loss, D near zero) and compare.

Predict

A 10 Gb/s link at 1550 nm has a 0 dBm laser 0.1 nm wide, a −24 dBm receiver, 5 dB of connectors, splices and margin, and fiber with 0.2 dB/km and D = 17 ps/(nm·km). What limits its reach?

Name it

The power budget

Start with the transmitter power and subtract every loss: fiber attenuation αL, connectors (about 0.5 dB each), splices (about 0.1 dB each), and a margin of 3 dB or more for aging, repairs and temperature. What remains must be at or above the receiver's sensitivity:

Pt−αL−Lother≥S

so the loss-limited reach is Lloss=Pt−S−Lotherα.

The dispersion budget

With the rough rule that pulses may spread by half a bit period, DLΔλ≤12B, so

Ldisp=12BDΔλ

Multimode fiber is rated instead by a modal bandwidth-distance product, such as 2000 MHz·km for OM3 fiber at 850 nm. A length L offers a bandwidth of that product divided by L, which should be at least about 0.7B for on-off signaling.

The design choices

ChoiceStrengthsLimits
850 nm, multimodecheap VCSEL lasers, silicon detectors, easy alignment2.5 dB/km or more, modal bandwidth: hundreds of meters at 10 Gb/s
1310 nm, single-modedispersion near zeroabout 0.35 dB/km
1550 nm, single-modelowest loss, 0.2 dB/km; optical amplifiers work hereD ≈ 17 ps/(nm·km), so narrow sources or compensation

A narrower source comes at a cost: a directly modulated laser's spectrum broadens as its current swings, while a laser left running steadily and switched by an external modulator (lesson 9) keeps a much narrower spectrum.

Worked example

A 10 Gb/s link must reach 300 m over OM3 multimode fiber (2000 MHz·km). Does modal bandwidth allow it?

Show the solution
  1. Bandwidth over 300 m. B=20000.3MHz=6.7GHz
  2. What the signal needs. 0.7×10=7GHz It's right at the limit, which is why the standard 10 Gb/s multimode links are specified for 300 m on this fiber.
  3. Loss. Loss is no issue: 0.3×3=0.9dB

Answer only just: 300 m gives 6.7 GHz against the 7 GHz the signal needs, and the loss is only 0.9 dB.

Worked example

Design the 60 km, 10 Gb/s link: 0 dBm laser, −24 dBm receiver, two connectors (0.5 dB each), a splice every 5 km (0.1 dB each), 3 dB margin.

Show the solution
  1. Losses at 1550 nm. The 12 reels of 5 km need 11 splices, 1.1 dB: loss=0.2×60+1+1.1+3=17.1dB leaving 6.9 dB to spare.
  2. Dispersion at 1550 nm. With a 0.1 nm source, 17×60×0.1=102ps double the 50 ps allowed.
  3. Try 1310 nm. Dispersion vanishes, but losses become loss=0.35×60+5.1=26.1dB over budget.
  4. A narrower source at 1550 nm. An externally modulated laser 0.02 nm wide gives 17×60×0.02=20ps comfortably inside.

Answer use 1550 nm with an externally modulated laser 0.02 nm wide: 17.1 dB of losses leaves 6.9 dB to spare, and dispersion is only 20 ps.

Check

A link sends −2 dBm over 70 km of fiber losing 0.35 dB/km, with two 0.5 dB connectors, 8 splices of 0.1 dB, and a −22 dBm receiver.

(a)

What are the total losses, before any margin?

(b)

How much margin is left? (A negative answer means the link fails.)

Check

A 10 Gb/s link uses fiber with D = 3 ps/(nm·km) and a source 0.2 nm wide.

(a)

How much spread does the half-bit rule allow?

Write units the way you normally would: 1.5 ps and 0.0015 ns are the same answer.

(b)

What is the dispersion-limited reach?

Check

A multimode fiber has a modal bandwidth-distance product of 2000 MHz·km and carries 1 Gb/s.

(a)

What bandwidth does the signal need, by the 0.7B rule?

Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.

(b)

How long can the fiber be?

Check

Write reach(p_tx, sens, other, alpha, B, D, dl): the reach of a link in km, the lower of the loss limit Pt−S−Lotherα and the dispersion limit 12BDΔλ. Units: dBm, dBm, dB, dB/km, Gb/s, ps/(nm·km), nm.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write cheapest(designs, L, B): each design is a dict with keys name, cost, p_tx, sens, other, alpha, D and dl. Return the name of the cheapest design whose reach (use your reach from above, rewritten here) is at least L km at B Gb/s, or None if none works.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

A link fails its dispersion budget. Why doesn't a more powerful laser fix it?

Practice

Keep practicing

6 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.