B8 · Lesson 9 · Interferometers
Measuring distances in fractions of a wavelength
In 2015 the LIGO detectors measured a change in the length of a 4 km tunnel of about m, a few thousandths of a proton's width, and heard two black holes merge. The instrument was an interferometer: it splits a laser beam in two, sends the halves along different paths and recombines them, and any change in one path's length shows up as a change in brightness. Smaller versions position the stages in chip lithography machines to nanometers, measure the spectra in chemistry labs, and switch the light in every long-haul fiber link.
- A Michelson interferometer's output brightness against how far one mirror has moved from equal arms. Moving the mirror by changes the path by .
- With a laser (narrow linewidth ), the fringes go on and on. Widen the linewidth toward white light and they survive only near equal arms.
- The readout gives the coherence length, the path difference over which fringes stay visible.
Predict
A Michelson interferometer uses a 633 nm laser. One mirror moves 1 mm. About how many bright fringes pass the detector?
About 3200. Moving the mirror by 1 mm lengthens that arm's round trip by 2 mm, which is wavelengths, and each wavelength of path brings one fringe. Counting fringes measures distance in steps of 316 nm, and electronics that read fractions of a fringe get down to nanometers.
Name it
The Michelson interferometer
A beam splitter sends half the light to each of two mirrors and recombines the returns. With arms differing in length by , the round-trip path difference is , and the output brightness is
Each time the mirror moves , one full fringe passes: . Anything that changes the optical path, , also shows: a gas cell of length adds of path when filled, which is how the refractive index of air is measured.
Coherence
Real sources span a range of wavelengths . Each wavelength makes its own fringe pattern, and they drift out of step as the path difference grows. Fringes stay visible only within the coherence length
A few micrometers for white light, meters for a good laser. Optical coherence tomography uses a deliberately short coherence length: only light reflected from one depth in tissue makes fringes, which slices an eye's retina into micrometer layers.
Other interferometers
- Mach–Zehnder: two separate paths, split and recombined. In a fiber-optic modulator, an electric field changes one arm's index by , adding a phase of ; a π shift turns the output from full to dark. Every long-haul data link uses one.
- Fabry–Pérot: two parallel mirrors facing each other. Light bounces many times and passes only at wavelengths that fit a whole number of round trips, . The transmitted peaks are spaced by the free spectral range . A laser's cavity is one (lesson 23).
- Gravitational-wave detectors: Michelsons with 4 km arms and the light bounced back and forth inside each arm. A passing wave stretches space by a strain , changing an arm by .
Worked example
A displacement interferometer counts 1000 fringes with a 632.8 nm helium-neon laser. How far did the mirror move?
Show the solution
- Motion per fringe. Each fringe is of mirror motion, 316.4 nm.
- Total motion.
Answer the mirror moved 316.4 µm.
Worked example
A 5 cm cell in one arm is filled with air () at 632.8 nm. How many fringes pass while it fills?
Show the solution
- Extra path. The light crosses the cell twice, so the path grows by
- Count the fringes.
Answer 46 fringes pass while the cell fills.
Worked example
One arm of a Michelson interferometer (633 nm) holds a glass cell 5 cm long. As the air is pumped out of the cell, 45.8 fringes pass the detector. What is the refractive index of air?
Show the solution
- Path change. The light crosses the cell twice, so removing the air shortens the optical path by , and each fringe is one wavelength:
- Solve for the index. So air's index is 1.00029.
- Where it matters. The same method measures the index of any gas, and tracking it is essential in precision length measurement, where air pressure and temperature shift the effective wavelength by parts per million.
Answer the refractive index of air is 1.00029.
Check
A Michelson interferometer's mirror moves 50 µm at 633 nm. How many fringes pass?
Check
A stage interferometer at 633 nm counts 1500 fringes. How far did the stage move?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
Check
A source at 850 nm has a linewidth of 0.01 nm. About what is its coherence length?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
Check
A Fabry–Pérot cavity has mirrors 5 mm apart, filled with a material of index 1. What is its free spectral range?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A modulator arm's index changes by 1 × 10⁻⁴ under its drive voltage. How long must the arm be for a π phase shift at 1310 nm?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A 5 cm gas cell in one arm of a Michelson changes index by 1 × 10⁻⁴ as it fills. How many fringes pass at 532 nm?
Check
A Michelson interferometer runs at 633 nm.
(a)
How many fringes pass when one mirror moves 0.1 mm?
(b)
How many pass as air (n − 1 = 2.9 × 10⁻⁴) is pumped out of a 10 cm cell in one arm?
Check
A Michelson interferometer at wavelength λ (write l).
Step 1
How many fringes pass when a mirror moves d?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
Roughly what coherence length does a source of bandwidth Δλ (write w) have?
Explain why
Why do white-light fringes appear only when a Michelson's arms are almost exactly equal?
White light contains a broad range of wavelengths, and each one makes its own pattern of bright and dark as the path difference changes. At zero path difference every wavelength is bright together. As the difference grows, the patterns go out of step, since a path difference that's a whole number of short wavelengths is not a whole number of long ones. After a few micrometers the brights of some colors fill the darks of others and the output is a steady average. That distance is the coherence length, set by how wide the spectrum is.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.