B8 · Lesson 16 · Optical fiber
Modes, dispersion and loss in the cables that carry the internet
Nearly all long-distance data travels as pulses of infrared light in glass fibers thinner than a hair. A good fiber loses only 0.2 dB per kilometer, so a signal still has 1% of its power after 100 km. Loss isn't the only limit, though. Pulses spread out as they travel, because different paths and different colors arrive at slightly different times, and after enough distance neighboring bits run into each other. Engineers manage both effects, and the design choices come down to a few numbers.
- Three "1" bits at bit rate leave the laser (dashed) and arrive after km of fiber (solid). The fiber's dispersion and the laser's spectral width Δλ spread each pulse by .
- At 10 Gb/s, how far can the signal go before the bits blur together?
- Now try 40 Gb/s, with pulses four times shorter. How does the reach change?
Predict
A 10 Gb/s link uses standard fiber (D = 17 ps/(nm·km)) and a laser with 0.1 nm of spectral width. Over 80 km, how does the pulse spread compare with the 100 ps bit period?
136 ps. Dispersion spreads a pulse by ps, longer than the 100 ps between bits. Such a link needs a laser with a narrower spectrum, dispersion compensation, or a receiver that undoes the spreading digitally, which is what modern coherent receivers do.
Name it
Modes
A step-index fiber has a core of radius and index in cladding of index , with numerical aperture NA (lesson 13). Light can only travel in certain field patterns, the modes, and the number of them is set by the V-number:
- : a single mode, the single-mode fiber used for long distances (core about 8 µm).
- Large : about modes, a multimode fiber (core 50 or 62.5 µm), easy to couple light into, used inside buildings.
The cutoff wavelength is the shortest wavelength at which a fiber is single-mode.
Dispersion
- Modal dispersion (multimode): rays at the edge of the acceptance cone travel farther than the axial ray. In a step-index fiber the delay spread is , tens of nanoseconds per kilometer. Graded-index cores, with the index falling smoothly outward, cut this a hundredfold.
- Chromatic dispersion (all fibers): the glass's index depends on wavelength, so a source of spectral width Δλ spreads by
with in ps/(nm·km), about 17 for standard fiber at 1550 nm and nearly zero at 1310 nm.
A rough limit is to keep the spread under about half a bit period.
Loss
Silica's loss has minima near 1310 nm (about 0.35 dB/km) and 1550 nm (about 0.2 dB/km), the two main telecom bands. A fiber link's power budget works like a radio link budget (B7.11): transmitter power, minus fiber loss , minus connectors and splices, must stay above the receiver's sensitivity with some margin.
Worked example
Standard single-mode fiber has = 4.1 µm and NA = 0.12. Is it single-mode at 1550 nm? What is its cutoff wavelength?
Show the solution
- V number at 1550 nm. below 2.405: single-mode.
- Cutoff wavelength. so it's single-mode at both 1310 and 1550 nm.
Answer yes, it's single-mode at 1550 nm, and its cutoff wavelength is 1.29 µm.
Worked example
A step-index multimode fiber has = 1.48 and = 1.46. How much does modal dispersion spread a pulse per kilometer?
Show the solution
- Travel time along the axis.
- Spread.
- What it limits. That limits a 1 km link to roughly 7 Mb/s, which is why multimode data links use graded-index fiber.
Answer modal dispersion spreads a pulse by 68 ns per kilometer.
Worked example
An 80 km link at 1550 nm uses fiber losing 0.2 dB/km, two connectors at 0.5 dB each, and a splice every 4 km at 0.1 dB. The laser launches 0 dBm and the receiver needs −28 dBm. What margin is left?
Show the solution
- Fiber and connectors. The fiber loses dB, and the connectors 1 dB.
- Splices. There are 19 splices between the 20 reels: 1.9 dB.
- Total loss.
- Margin. The received power is −18.9 dBm, leaving a margin of 9.1 dB above the receiver's −28 dBm.
- What the margin covers. That margin covers aging, repairs (each adds a splice) and temperature.
- Reach without amplifiers. The 28 dB budget, after the connectors' 1 dB, at 0.225 dB/km (splices included) runs out near with no margin at all, which is why long routes add erbium amplifiers every 80 km or so.
Answer the link loses 18.9 dB, so 9.1 dB of margin is left.
Check
A fiber has a core radius of 4.1 µm and NA = 0.12. What is its V-number at 1550 nm?
Check
A fiber's core radius is 4 µm and its NA is 0.11. Below what wavelength does it stop being single-mode?
Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.
Check
A step-index multimode fiber has core index 1.46 and cladding index 0.005 lower. How much does modal dispersion spread a pulse over 2 km?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A fiber with D = 4 ps/(nm·km) carries a source 0.5 nm wide over 10 km. How much does chromatic dispersion spread each pulse?
Write units the way you normally would: 1.5 ps and 0.0015 ns are the same answer.
Check
A 0 dBm transmitter feeds a receiver with −24 dBm sensitivity over fiber with 0.35 dB/km of loss, and connectors and splices cost 3 dB in total. How long can the fiber be, with no margin left over?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
About how many modes does a step-index fiber carry, with a 25 µm core radius and NA = 0.2, at 1300 nm?
Check
A fiber link of 20 km loses 0.2 dB/km, with 3 dBm launched and no other losses.
(a)
What power arrives?
(b)
What percentage of the launched power is that?
Check
A fiber losing α dB/km (write a) carries P dBm over L km.
Step 1
What power arrives, in dBm?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What fraction of the power survives?
Explain why
Why do long-distance links use single-mode fiber, when multimode fiber is easier to couple light into?
In multimode fiber, light travels along many paths at once, some straight down the axis and some zigzagging at steep angles. The longer paths arrive later, so every pulse spreads in time by tens of nanoseconds per kilometer in a step-index fiber, and the spreading grows with distance. Over many kilometers that would blur bits together at any useful data rate. A single-mode fiber has only one path, so modal spreading disappears and only the much smaller chromatic dispersion remains, which allows high data rates over hundreds of kilometers.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.