title: Optical fiber
heading: Modes, dispersion and loss in the cables that carry the internet
eyebrow: B8 · Lesson 16 · Optical fiber
xp: 40
---

::: hook
Nearly all long-distance data travels as pulses of infrared light in glass fibers thinner than a hair. A good fiber loses only 0.2 dB per kilometer, so a signal still has 1% of its power after 100 km. Loss isn't the only limit, though. Pulses spread out as they travel, because different paths and different colors arrive at slightly different times, and after enough distance neighboring bits run into each other. Engineers manage both effects, and the design choices come down to a few numbers.
:::

::: play
- Three "1" bits at bit rate $B$ leave the laser (dashed) and arrive after $L$ km of fiber (solid). The fiber's dispersion $D$ and the laser's spectral width Δλ spread each pulse by $DL\Delta\lambda$.
- At 10 Gb/s, how far can the signal go before the bits blur together?
- Now try 40 Gb/s, with pulses four times shorter. How does the reach change?
:::
:::

```sim plot
view: graph
x: t = -300..300 ps
y: P = 0..1.2
slider: B = 1..40 step 0.5 = 10 Gb/s
slider: L = 1..200 = 20 km log
slider: D = 0..20 step 0.5 = 17
slider: dl = 0.01..1 = 0.1 nm log
plot: exp(-4*ln(2)*((t + 1000/B)/(500/B))^2) + exp(-4*ln(2)*(t/(500/B))^2) + exp(-4*ln(2)*((t - 1000/B)/(500/B))^2) | label: sent | dashed | color: ch2 | samples: 900
plot: (500/B)/sqrt((500/B)^2 + (D*L*dl)^2)*(exp(-4*ln(2)*(t + 1000/B)^2/((500/B)^2 + (D*L*dl)^2)) + exp(-4*ln(2)*t^2/((500/B)^2 + (D*L*dl)^2)) + exp(-4*ln(2)*(t - 1000/B)^2/((500/B)^2 + (D*L*dl)^2))) | label: received | samples: 900
readout: spread, ps = D*L*dl | digits: 3
readout: bit period, ps = 1000/B | digits: 3
```

::: predict
## A 10 Gb/s link uses standard fiber (D = 17 ps/(nm·km)) and a laser with 0.1 nm of spectral width. Over 80 km, how does the pulse spread compare with the 100 ps bit period?

- [ ] Negligible, about 1 ps
- [ ] About 14 ps
- [x] About 136 ps, more than a bit period
- [ ] About 1360 ps

::: reveal
136 ps. Dispersion spreads a pulse by $DL\Delta\lambda = 17 \times 80 \times 0.1$ ps, longer than the 100 ps between bits. Such a link needs a laser with a narrower spectrum, dispersion compensation, or a receiver that undoes the spreading digitally, which is what modern coherent receivers do.
:::
:::

::: nameit
## Modes

A step-index fiber has a core of radius $a$ and index $n_1$ in cladding of index $n_2$, with numerical aperture NA $= \sqrt{n_1^2 - n_2^2}$ (lesson 13). Light can only travel in certain field patterns, the **modes**, and the number of them is set by the **V-number**:

$$V = \frac{2\pi a}{\lambda}\text{NA}$$

- $V < 2.405$: a single mode, the **single-mode** fiber used for long distances (core about 8 µm).
- Large $V$: about $V^2/2$ modes, a **multimode** fiber (core 50 or 62.5 µm), easy to couple light into, used inside buildings.

The **cutoff wavelength** $\lambda_c = \frac{2\pi a\text{NA}}{2.405}$ is the shortest wavelength at which a fiber is single-mode.

## Dispersion

- **Modal dispersion** (multimode): rays at the edge of the acceptance cone travel farther than the axial ray. In a step-index fiber the delay spread is $\Delta t = \frac{Ln_1}{c}\left(\frac{n_1}{n_2} - 1\right)$, tens of nanoseconds per kilometer. Graded-index cores, with the index falling smoothly outward, cut this a hundredfold.
- **Chromatic dispersion** (all fibers): the glass's index depends on wavelength, so a source of spectral width Δλ spreads by

$$\Delta t = DL\Delta\lambda$$

with $D$ in ps/(nm·km), about 17 for standard fiber at 1550 nm and nearly zero at 1310 nm.

A rough limit is to keep the spread under about half a bit period.

## Loss

Silica's loss has minima near 1310 nm (about 0.35 dB/km) and 1550 nm (about 0.2 dB/km), the two main telecom bands. A fiber link's power budget works like a radio link budget (B7.11): transmitter power, minus fiber loss $\alpha L$, minus connectors and splices, must stay above the receiver's sensitivity with some margin.
:::

::: example
## Standard single-mode fiber has $a$ = 4.1 µm and NA = 0.12. Is it single-mode at 1550 nm? What is its cutoff wavelength?

::: solution
1. **V number at 1550 nm.**
   $$\begin{aligned} V &= \frac{2\pi \times 4.1}{1.55} \times 0.12 \\ &= 1.99 \end{aligned}$$
   below 2.405: single-mode.
2. **Cutoff wavelength.**
   $$\begin{aligned} \lambda_c &= \frac{2\pi \times 4.1 \times 0.12}{2.405} \\ &= 1.29\ \mu\text{m} \end{aligned}$$
   so it's single-mode at both 1310 and 1550 nm.

**Answer:** yes, it's single-mode at 1550 nm, and its cutoff wavelength is 1.29 µm.
:::
:::

::: example
## A step-index multimode fiber has $n_1$ = 1.48 and $n_2$ = 1.46. How much does modal dispersion spread a pulse per kilometer?

::: solution
1. **Travel time along the axis.**
   $$\begin{aligned} \frac{Ln_1}{c} &= \frac{1000 \times 1.48}{3 \times 10^8}\ \text{s} \\ &= 4.93\ \mu\text{s} \end{aligned}$$
2. **Spread.**
   $$\begin{aligned} \Delta t &= \frac{Ln_1}{c}\left(\frac{n_1}{n_2} - 1\right) \\ &= 4.93\ \mu\text{s} \times 0.0137 \\ &= 68\ \text{ns} \end{aligned}$$
3. **What it limits.** That limits a 1 km link to roughly 7 Mb/s, which is why multimode data links use graded-index fiber.

**Answer:** modal dispersion spreads a pulse by 68 ns per kilometer.
:::
:::

::: example
## An 80 km link at 1550 nm uses fiber losing 0.2 dB/km, two connectors at 0.5 dB each, and a splice every 4 km at 0.1 dB. The laser launches 0 dBm and the receiver needs −28 dBm. What margin is left?

::: solution
1. **Fiber and connectors.** The fiber loses $0.2 \times 80 = 16$ dB, and the connectors 1 dB.
2. **Splices.** There are 19 splices between the 20 reels: 1.9 dB.
3. **Total loss.**
   $$\begin{aligned} \text{loss} &= 16 + 1 + 1.9 \\ &= 18.9\ \text{dB} \end{aligned}$$
4. **Margin.** The received power is −18.9 dBm, leaving a margin of 9.1 dB above the receiver's −28 dBm.
5. **What the margin covers.** That margin covers aging, repairs (each adds a splice) and temperature.
6. **Reach without amplifiers.** The 28 dB budget, after the connectors' 1 dB, at 0.225 dB/km (splices included) runs out near
   $$\frac{28 - 1}{0.225} = 120\ \text{km}$$
   with no margin at all, which is why long routes add erbium amplifiers every 80 km or so.

**Answer:** the link loses 18.9 dB, so 9.1 dB of margin is left.
:::
:::

::: check
given: a = 4.1 | 25; NA = 0.12 | 0.2; lam = 850 | 1550
answer: 2*pi*a*NA/(lam/1000)
tolerance: 0.5%

## A fiber has a core radius of {a} µm and NA = {NA}. What is its V-number at {lam} nm?

::: right
Right. $V = \frac{2\pi a}{\lambda}\text{NA}$ = {answer}.
:::

::: misses
- [2*pi*a*NA/lam] Put the radius and wavelength in the same units.
- [any] Not yet. $V = 2\pi a\,\text{NA}/\lambda$.
:::
:::

::: check
given: a = 3 | 4 | 4.5; NA = 0.11 | 0.14
answer: 2*pi*a*NA/2.405*1000
unit: nm
tolerance: 0.5%

## A fiber's core radius is {a} µm and its NA is {NA}. Below what wavelength does it stop being single-mode?

::: right
Right. $\lambda_c = \frac{2\pi a\text{NA}}{2.405}$ = {answer}.
:::

::: misses
- [any] Not yet. Set $V = 2.405$ and solve for λ.
:::
:::

::: check
given: n1 = 1.46 | 1.48; d = 0.005 | 0.01 | 0.02; L = 0.5 | 2
answer: L*1000*n1/3e8*(n1/(n1 - d) - 1)*1e9
unit: ns
tolerance: 0.5%

## A step-index multimode fiber has core index {n1} and cladding index {d} lower. How much does modal dispersion spread a pulse over {L} km?

::: right
Right. $\frac{Ln_1}{c}\left(\frac{n_1}{n_2} - 1\right)$ = {answer}.
:::

::: misses
- [L*1000/3e8*(n1/(n1 - d) - 1)*1e9] The light travels at $c/n_1$ in the core.
- [any] Not yet. Compare the axial ray with the one at the critical angle.
:::
:::

::: check
given: D = 4 | 17; L = 10 | 80; dl = 0.05 | 0.5
answer: D*L*dl
unit: ps
tolerance: 0.5%

## A fiber with D = {D} ps/(nm·km) carries a source {dl} nm wide over {L} km. How much does chromatic dispersion spread each pulse?

::: right
Right. $DL\Delta\lambda$ = {answer}.
:::

::: misses
- [any] Not yet. Multiply the three.
:::
:::

::: check
given: P = -3 | 0 | 3; S = -24 | -32; a = 0.2 | 0.35; c = 1 | 3
answer: (P - S - c)/a
unit: km
tolerance: 0.5%

## A {P} dBm transmitter feeds a receiver with {S} dBm sensitivity over fiber with {a} dB/km of loss, and connectors and splices cost {c} dB in total. How long can the fiber be, with no margin left over?

::: right
Right. $\frac{P_t - S - L_c}{\alpha}$ = {answer}.
:::

::: misses
- [(P - S)/a] Subtract the connector and splice losses first.
- [any] Not yet. Spend the budget $P_t - S$ on connectors and then fiber.
:::
:::

::: check
given: a = 25 | 31.25; NA = 0.2 | 0.275; lam = 850 | 1300
answer: (2*pi*a*NA/(lam/1000))^2/2
tolerance: 1%

## About how many modes does a step-index fiber carry, with a {a} µm core radius and NA = {NA}, at {lam} nm?

::: right
Right. $V^2/2$ = {answer}.
:::

::: misses
- [2*pi*a*NA/(lam/1000)] That's $V$; the mode count is about $V^2/2$.
- [any] Not yet. Find $V$, then $V^2/2$.
:::
:::

::: check
kind: parts
given: a = 0.2 | 0.35; L = 20 | 80; P = 0 | 3

## A fiber link of {L} km loses {a} dB/km, with {P} dBm launched and no other losses.

::: part
answer: P - a*L
unit: dBm
tolerance: 0.5%

### What power arrives?

::: misses
- [any] Subtract $\alpha L$ in decibels.
:::
:::

::: part
answer: 10^(-a*L/10)*100
unit: %
tolerance: 0.5%

### What percentage of the launched power is that?

::: misses
- [10^(-a*L/20)*100] Power uses $10^{-\text{dB}/10}$.
- [any] $10^{-\alpha L/10}$.
:::
:::
:::

::: check
kind: derivation
vars: a = 0.1..3, L = 1..100, P = -10..10

## A fiber losing α dB/km (write a) carries P dBm over L km.

::: step
answer: P - a*L

### What power arrives, in dBm?
:::

::: step
answer: 10^(-a*L/10)

### What fraction of the power survives?
:::

::: right
Right. In decibels losses subtract; as fractions, they multiply.
:::
:::

::: explain
## Why do long-distance links use single-mode fiber, when multimode fiber is easier to couple light into?

::: model
In multimode fiber, light travels along many paths at once, some straight down the axis and some zigzagging at steep angles. The longer paths arrive later, so every pulse spreads in time by tens of nanoseconds per kilometer in a step-index fiber, and the spreading grows with distance. Over many kilometers that would blur bits together at any useful data rate. A single-mode fiber has only one path, so modal spreading disappears and only the much smaller chromatic dispersion remains, which allows high data rates over hundreds of kilometers.
:::
:::

::: practice

::: check
given: a = 0.2 | 0.35; L = 20 | 100
answer: a*L
unit: dB
tolerance: 0.5%

## A fiber loses {a} dB/km. How much does {L} km lose?

::: misses
- [any] $\alpha L$.
:::
:::

::: check
given: B = 2.5 | 10 | 40
answer: 1000/B
unit: ps
tolerance: 0.5%

## What is the bit period at {B} Gb/s?

::: misses
- [any] $1/B$.
:::
:::

::: check
given: n1 = 1.45 | 1.5; n2 = 1.44 | 1.43
answer: sqrt(n1^2 - n2^2)
tolerance: 0.5%

## What is the numerical aperture of a fiber with core index {n1} and cladding index {n2}?

::: misses
- [any] $\sqrt{n_1^2 - n_2^2}$.
:::
:::
:::