B9 · Lesson 19 · The Hall effect
Counting carriers, telling their sign, and sensing magnetic fields
Pass a current along a thin strip of semiconductor in a magnetic field and a small voltage appears across the strip, sideways to the current. Its size tells you how many carriers there are; its sign tells you whether they're electrons or holes. That measurement, discovered by Edwin Hall in 1879, is how holes were shown to be real positive carriers, and how every semiconductor wafer's doping and mobility are checked. The same effect, packaged as a chip, senses the rotor position in brushless motors, measures current without touching the wire, and finds north in a phone.
- A current flows along a strip of thickness with carriers per cm³, in a field through the strip. The line is the Hall voltage across it against .
- Fewer carriers means a bigger voltage: the same current must flow with faster carriers, which feel a bigger magnetic push.
- Try metal-like densities ( cm⁻³ and up): the voltage almost vanishes. That's why Hall sensors are made of semiconductors.
Predict
A copper strip and a silicon strip of the same size carry the same current in the same field. How do their Hall voltages compare?
Silicon's, by millions. The Hall voltage is : for the same current, fewer carriers must each move faster, and the magnetic force grows with speed. Copper has about free electrons per cm³; lightly doped silicon, around to .
Name it
The Hall voltage
Carriers drifting at along a strip, through a magnetic field square to the strip, feel a sideways force (B5). They pile up on one edge until the resulting sideways field pushes back equally: . With current through a strip of width and thickness (measured along ), the voltage across the width is
What it measures
- Carrier density: . The Hall coefficient is a property of the material.
- Carrier sign: electrons and holes drifting in opposite directions are pushed to the same side, so the Hall voltage has opposite signs for n-type and p-type material. Hall measurements on p-type samples gave the first direct evidence that holes behave as positive carriers.
- Mobility: combine with the resistivity, , to get , the Hall mobility. Measuring ρ and on one sample is the standard way to characterize a semiconductor wafer.
Hall sensors
A sensor wants a big voltage per tesla: a thin layer with few carriers. Real sensors use thin films of indium antimonide or gallium arsenide, or lightly doped silicon with an amplifier on the same chip. They read fields from microteslas (electronic compasses) to teslas, with no moving parts and no contact: rotor position in brushless motors, wheel speed in cars, and current sensors that measure the field around a conductor without touching it.
Worked example
A silicon Hall plate has cm⁻³ and is 10 µm thick. With 1 mA flowing, what voltage does a 10 mT field give?
Show the solution
- Convert to SI units.
- Hall voltage.
- Sensitivity. That's 62 µV per mT.
Answer 0.62 mV, a sensitivity of 62 µV per mT.
Worked example
A sample measures = 0.5 Ω·cm and cm³/C. What type is it, and what are its carrier density and mobility?
Show the solution
- Carrier type. The Hall coefficient is negative, so the sample is n-type.
- Carrier density.
- Mobility. just what lesson 17's fit gives for that doping.
Answer n-type, with electrons per cm³ and a mobility of 1250 cm²/(V·s).
Worked example
A Hall plate 10 µm thick, with 10¹⁶ carriers per cm³, is driven with 1 mA. What is its sensitivity, and what voltage does a 10 mT field give?
Show the solution
- Sensitivity. or 62.4 mV/T.
- At 10 mT. So 10 mT gives 0.62 mV.
- Why semiconductors. Lightly doped, thin semiconductors make good Hall sensors because few carriers must each carry a lot of drift velocity.
- Compare with copper. A copper plate the same size would give about eight million times less.
Answer 62.4 mV/T, so 10 mT gives 0.62 mV.
Check
A strip 20 µm thick with 1 × 10¹⁶ carriers per cm³ carries 1 mA in a 10 mT field. What is the Hall voltage?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A strip 50 µm thick carrying 1 mA in a 100 mT field shows a Hall voltage of 10 mV. What is its carrier density?
Check
A sample has = 6250 cm³/C and a resistivity of 0.5 Ω·cm. What is its Hall mobility?
Check
A copper strip ( m⁻³) 0.5 mm thick carries 5 A in a 0.5 T field. What Hall voltage appears?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
Check
Carriers drift at 100 m/s in a strip 5 mm wide, in a 0.1 T field. What Hall voltage builds up across it?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A Hall measurement gives a positive Hall coefficient. What does that say about the sample?
Check
A Hall plate 20 µm thick with 1 × 10¹⁵ carriers per cm³ is driven with 0.5 mA.
(a)
What is its sensitivity?
Write units the way you normally would: 1.5 V/T, 1500 mV/T and 0.0015 kV/T are the same answer.
(b)
What voltage does a 50 mT field give?
Check
A Hall plate of thickness t, carrier density n (per m³), current I, in field B.
Step 1
What is the Hall voltage?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is the Hall coefficient?
Explain why
Why are electrons and holes pushed to the same side of a strip, even though they have opposite charges?
The magnetic force on a moving charge depends on both its charge and its velocity. For the same current direction, holes drift along with the current and electrons drift against it. Flipping the charge flips the force, and flipping the velocity flips it again, so the two flips cancel and both kinds of carrier are pushed toward the same edge. That edge then charges positive with holes or negative with electrons, which is why the sign of the Hall voltage reveals the carrier type.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.