B927 of 29
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B9 · Lesson 27 · Project

Use mobility and intrinsic carriers to design a sensor and find its limits

Car engines, motor windings and battery packs are often watched by silicon temperature sensors: a tiny chip of lightly doped silicon whose resistance rises about 0.8% per kelvin. The physics is all in this course. Doping fixes the number of carriers, so the resistance tracks the mobility, which falls as the crystal vibrates harder. Heat it too far and the intrinsic carriers of lesson 15 flood in, the resistance turns around and falls, and the sensor gives two temperatures for one reading. In this project you'll model the sensor, find where it turns around, and choose a doping for a rated temperature range.

  • A silicon sensor's resistance relative to its value at 300 K, against temperature, for doping Nd (log₁₀ per cm³).
  • Over the working range it climbs smoothly, roughly as T2.4. Then it peaks and falls as intrinsic carriers take over.
  • Lighter doping gives more resistance from a small chip, but it turns around at a lower temperature. Find the lightest doping that still works up to 200 °C (473 K).

Predict

A silicon sensor's resistance follows T2.4 near room temperature. What is its temperature coefficient at 300 K?

Name it

The model

Lightly doped n-type silicon, with every donor ionized:

  • Carriers: n=Nd2+Nd24+ni2 and p=ni2/n (lesson 15), with ni=2.4×1019(T/300)3/2e−Eg/2kT cm⁻³ and Eg = 1.12 eV.
  • Mobilities, lattice-limited at light doping (lesson 17): μn=1350(T/300)−2.4 and μp=450(T/300)−2.2 cm²/(V·s).
  • Resistance: R∝1σ with σ=e(nμn+pμp), scaled so R=R300 at 300 K.

The working range

In the extrinsic range n≈Nd is constant and R∝T2.4: a smooth, monotonic curve with a coefficient of 2.4T. As ni approaches Nd, carriers multiply faster than mobility falls, dR/dT shrinks to zero at a peak, and beyond it the resistance falls. Above the peak a reading is ambiguous, so the sensor's rated maximum must sit safely below it.

Design trade-offs

  • Lighter doping gives a higher resistivity, so a tiny chip still has a convenient resistance, like 1 kΩ, with little current and little self-heating. But it turns intrinsic sooner.
  • Self-heating: the measuring current dissipates I2R, which warms the chip by I2Rθ, with θ its thermal resistance to its surroundings in K/mW. Keep the current small.
  • Reading back: in the working range, T≈300(R/R300)1/2.4 K, refined with a calibration table.

Worked example

A sensor reads 1000 Ω at 300 K. What does the T2.4 law predict at 400 K, and what temperature does 1500 Ω mean?

Show the solution
  1. At 400 K. R=1000×(400/300)2.4=1995Ω
  2. The temperature for 1500 Ω. T=300×1.51/2.4=355K or 82 °C.
  3. Compare with the full model. The full model agrees closely until intrinsic carriers matter.

Answer 1995 Ω at 400 K, and 1500 Ω means 355 K (82 °C).

Worked example

A 1 kΩ sensor with a thermal resistance of 0.5 K/mW is read with 1 mA. How much does it heat itself?

Show the solution
  1. Power. P=I2R=(10−3)2×1000=1mW
  2. Temperature rise. ΔT=1×0.5=0.5K so the sensor reads half a degree high.
  3. A smaller current. At 0.1 mA the error drops a hundredfold, to 5 mK.

Answer it heats itself by 0.5 K, so it reads half a degree high.

Check

A silicon sensor follows R∝T2.4. What is its temperature coefficient at 350 K?

Check

A sensor reads 1000 Ω at 300 K and follows T2.4. What does it read at 250 K?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A sensor's resistance is 1.5 times its 300 K value. What temperature does the T2.4 law give?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

A 1 kΩ sensor with a thermal resistance of 1 K/mW is read with 0.5 mA. How much does it heat itself?

Write units the way you normally would: 1.5 mK, 1500 µK and 0.0015 K are the same answer.

Check

Write resistance(T, Nd, R300=1000.0) for the model above: the sensor's resistance at temperature T (K) with Nd donors per cm³, scaled so it equals R300 at 300 K.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write peak_temp(Nd): the temperature (K) where the resistance peaks, found by bisection between 300 and 1200 K on the sign of dR/dT. Estimate the slope with a central difference, (resistance(T + 0.01, Nd) - resistance(T - 0.01, Nd)) / 0.02.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write design(Tmax, margin=50.0): from the dopings [1e14, 2e14, 5e14, 1e15, 2e15, 5e15, 1e16], return the lightest whose resistance peak is at least Tmax + margin kelvin, or None if none is. Your peak_temp is included.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why does a lightly doped silicon sensor's resistance rise with temperature, when pure silicon's falls?

Practice

Keep practicing

7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.