C122 of 30
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C1 · Lesson 22 · Bridges and sensors

Measuring tiny changes in resistance with a Wheatstone bridge

A strain gauge glued to a steel beam changes its resistance by 0.2% when the beam stretches a thousandth of its length. Measured directly, that's 0.7 Ω out of 350, hard to see against the gauge's own tolerance and its drift with temperature. Put the gauge in a Wheatstone bridge and the 350 Ω disappears: the bridge's output is zero at rest and responds only to the change. Bathroom scales, load cells, pressure sensors and precision thermometers all work this way.

  • Output voltage against strain for a bridge from Vs with gauges of gauge factor GF. The three lines are a quarter bridge (one active gauge), a half bridge (two, one stretched and one squeezed) and a full bridge (four).
  • Each step doubles the output. The quarter bridge also bends slightly: its output isn't quite proportional to strain.
  • The readouts give each output at the marked strain.

Predict

A 350 Ω strain gauge (gauge factor 2) in a quarter bridge from 5 V sees 1000 µε of strain. About what voltage appears across the bridge?

Name it

The Wheatstone bridge

Two dividers from the same supply Vs: R1 over R3 to node a, and R2 over R4 to node b. The output is the difference between their midpoints:

Vout=Va−Vb=Vs(R3R1+R3−R4R2+R4)

It's zero when the bridge is balanced, R1/R3=R2/R4 (lesson 11). Any arm that changes unbalances it.

Sensitivity

With all four arms equal to R at rest and active arms changing by a fraction x:

BridgeActive armsOutput
quarterone, R(1+x)Vsx2(2+x)≈Vsx4
halftwo, R(1+x) and R(1−x) on the same sideVsx2
fullfour, alternatingVsx

The half and full bridges are exactly linear, and they cancel temperature: a temperature change affects every gauge alike, which leaves the bridge balanced.

Resistive sensors

  • Strain gauges: a fine metal foil whose resistance changes by ΔRR=GF⋅ε, with gauge factor about 2 and strain ε in parts per million (µε).
  • RTDs: platinum, R=R0(1+αT) with R0 = 100 Ω (Pt100) and α = 0.00385 per °C.
  • Thermistors and light-dependent resistors change much more, but less linearly (lesson 28).

Null measurement

The oldest use: put an unknown resistor in one arm and adjust a calibrated one until the output is zero, then Rx=RdR2/R1 from the balance condition. The reading doesn't depend on the supply voltage or the meter's calibration, only on the reference resistors.

Worked example

A 350 Ω gauge (GF = 2.0) sees 1000 µε in a quarter bridge from 5 V. What are the resistance change and the output?

Show the solution
  1. Resistance change. ΔR=350×2.0×10−3=0.70Ω
  2. Exact output. Vout=5×0.0022×2.002=2.4975mV
  3. The approximation. Vsx4 gives 2.5 mV, 0.1% high.

Answer the resistance changes by 0.70 Ω, and the bridge outputs 2.4975 mV.

Worked example

A Pt100 RTD at 100 °C sits in a bridge with three 100 Ω resistors, from 5 V. What does it output?

Show the solution
  1. RTD resistance. R=100(1+0.00385×100)=138.5Ω
  2. Bridge output. With the RTD as R3: Vout=5(138.5238.5−12)=0.404V
  3. Linearity. A change this large is well into the nonlinear range, so RTD bridges are usually linearized in software.

Answer the bridge outputs 0.404 V.

Worked example

An NTC thermistor (10 kΩ at 25 °C, β = 3950 K) sits on top of a fixed 10 kΩ, from 3.3 V. What does the divider output at 0 °C, 25 °C and 50 °C?

Show the solution
  1. Thermistor resistance. With T in kelvin, R(T)=10kΩ×eβ(1/T−1/298.15) which gives 33.6 kΩ at 0 °C, 10 kΩ at 25 °C and 3.59 kΩ at 50 °C.
  2. Output. The output is across the fixed resistor: v=3.3×1010+R(T)
  3. At each temperature. v(0°C)=0.757Vv(25°C)=1.650Vv(50°C)=2.429V
  4. Compare the ranges. The thermistor's resistance changes by a factor of 9.4, but the output only by 3.2, and much more evenly: a fixed resistor equal to the thermistor's mid-range value linearizes it over the range that matters.

Answer the divider outputs 0.757 V at 0 °C, 1.650 V at 25 °C and 2.429 V at 50 °C.

Check

A 350 Ω strain gauge with gauge factor 2 sees 1500 µε. By how much does its resistance change?

Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.

Check

A quarter bridge from 5 V has one gauge (GF = 2) at 2000 µε. Using the small-change approximation, what is its output?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

A bridge from 5 V has R1 = 1000 Ω over R3 = 1100 Ω on one side and 1 kΩ over 1 kΩ on the other. What is Va−Vb?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

What is a Pt100 RTD's resistance at 25 °C, with α = 0.00385 per °C?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A full bridge of four gauges (GF = 2) from 5 V measures 800 µε. What is its output?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

A bridge balances with the decade box at 1234 Ω, with ratio arms R1 = 100 Ω and R2 = 10000 Ω. Using Rx=RdR2/R1, what is the unknown?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

An NTC thermistor (10 kΩ at 25 °C, β = 3435 K) sits above a fixed 10 kΩ, from 3.3 V, at 40 °C.

(a)

What's its resistance?

Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.

(b)

What does the divider output across the fixed resistor?

Check

A bridge from V has one arm changed by a fraction x; the other three are equal.

Step 1

What's the exact output?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why is a half bridge with one gauge stretched and one squeezed better than a quarter bridge, beyond doubling the output?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.