C1 · Lesson 22 · Bridges and sensors
Measuring tiny changes in resistance with a Wheatstone bridge
A strain gauge glued to a steel beam changes its resistance by 0.2% when the beam stretches a thousandth of its length. Measured directly, that's 0.7 Ω out of 350, hard to see against the gauge's own tolerance and its drift with temperature. Put the gauge in a Wheatstone bridge and the 350 Ω disappears: the bridge's output is zero at rest and responds only to the change. Bathroom scales, load cells, pressure sensors and precision thermometers all work this way.
- Output voltage against strain for a bridge from with gauges of gauge factor GF. The three lines are a quarter bridge (one active gauge), a half bridge (two, one stretched and one squeezed) and a full bridge (four).
- Each step doubles the output. The quarter bridge also bends slightly: its output isn't quite proportional to strain.
- The readouts give each output at the marked strain.
Predict
A 350 Ω strain gauge (gauge factor 2) in a quarter bridge from 5 V sees 1000 µε of strain. About what voltage appears across the bridge?
About 2.5 mV. The gauge changes by , 0.2%. A quarter bridge turns a small fractional change into about : mV, zero at rest. Small, but an amplifier can boost it a thousandfold without the 2.5 V common to both sides getting in the way (C6).
Name it
The Wheatstone bridge
Two dividers from the same supply : over to node , and over to node . The output is the difference between their midpoints:
It's zero when the bridge is balanced, (lesson 11). Any arm that changes unbalances it.
Sensitivity
With all four arms equal to at rest and active arms changing by a fraction :
| Bridge | Active arms | Output |
|---|---|---|
| quarter | one, | |
| half | two, and on the same side | |
| full | four, alternating |
The half and full bridges are exactly linear, and they cancel temperature: a temperature change affects every gauge alike, which leaves the bridge balanced.
Resistive sensors
- Strain gauges: a fine metal foil whose resistance changes by , with gauge factor about 2 and strain ε in parts per million (µε).
- RTDs: platinum, with = 100 Ω (Pt100) and α = 0.00385 per °C.
- Thermistors and light-dependent resistors change much more, but less linearly (lesson 28).
Null measurement
The oldest use: put an unknown resistor in one arm and adjust a calibrated one until the output is zero, then from the balance condition. The reading doesn't depend on the supply voltage or the meter's calibration, only on the reference resistors.
Worked example
A 350 Ω gauge (GF = 2.0) sees 1000 µε in a quarter bridge from 5 V. What are the resistance change and the output?
Show the solution
- Resistance change.
- Exact output.
- The approximation. gives 2.5 mV, 0.1% high.
Answer the resistance changes by 0.70 Ω, and the bridge outputs 2.4975 mV.
Worked example
A Pt100 RTD at 100 °C sits in a bridge with three 100 Ω resistors, from 5 V. What does it output?
Show the solution
- RTD resistance.
- Bridge output. With the RTD as :
- Linearity. A change this large is well into the nonlinear range, so RTD bridges are usually linearized in software.
Answer the bridge outputs 0.404 V.
Worked example
An NTC thermistor (10 kΩ at 25 °C, β = 3950 K) sits on top of a fixed 10 kΩ, from 3.3 V. What does the divider output at 0 °C, 25 °C and 50 °C?
Show the solution
- Thermistor resistance. With T in kelvin, which gives 33.6 kΩ at 0 °C, 10 kΩ at 25 °C and 3.59 kΩ at 50 °C.
- Output. The output is across the fixed resistor:
- At each temperature.
- Compare the ranges. The thermistor's resistance changes by a factor of 9.4, but the output only by 3.2, and much more evenly: a fixed resistor equal to the thermistor's mid-range value linearizes it over the range that matters.
Answer the divider outputs 0.757 V at 0 °C, 1.650 V at 25 °C and 2.429 V at 50 °C.
Check
A 350 Ω strain gauge with gauge factor 2 sees 1500 µε. By how much does its resistance change?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A quarter bridge from 5 V has one gauge (GF = 2) at 2000 µε. Using the small-change approximation, what is its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A bridge from 5 V has = 1000 Ω over = 1100 Ω on one side and 1 kΩ over 1 kΩ on the other. What is ?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
What is a Pt100 RTD's resistance at 25 °C, with α = 0.00385 per °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A full bridge of four gauges (GF = 2) from 5 V measures 800 µε. What is its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A bridge balances with the decade box at 1234 Ω, with ratio arms = 100 Ω and = 10000 Ω. Using , what is the unknown?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
An NTC thermistor (10 kΩ at 25 °C, β = 3435 K) sits above a fixed 10 kΩ, from 3.3 V, at 40 °C.
(a)
What's its resistance?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
(b)
What does the divider output across the fixed resistor?
Check
A bridge from V has one arm changed by a fraction x; the other three are equal.
Step 1
What's the exact output?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's the small-change approximation?
Step 3
What's the ratio of exact to approximate?
Explain why
Why is a half bridge with one gauge stretched and one squeezed better than a quarter bridge, beyond doubling the output?
In a half bridge both gauges sit in the same half of the bridge, one stretched and one squeezed, so their resistance changes are equal and opposite and the output becomes exactly proportional to strain, removing the quarter bridge's slight curve. Both gauges are also the same type at the same temperature, so when the temperature changes they drift together, and a common change in two arms of the same divider leaves its ratio, and the output, unchanged. The half bridge cancels the thermal drift that would otherwise look like strain.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.