title: Meters and loading
heading: Why connecting a meter changes what it measures
eyebrow: C1 · Lesson 8 · Meters and loading
xp: 40
---

::: hook
A voltmeter has to draw a little current to measure anything, and an ammeter has a little resistance of its own. Connect one to a circuit and the circuit is no longer quite the one you meant to measure. With a 10 MΩ multimeter on a divider of 10 kΩ resistors you'll never notice. On a divider of megohm resistors, the reading can be off by several percent, and an engineer who doesn't expect it will chase a fault that isn't there. Thevenin's theorem (lesson 15) explains exactly how much, and the same thinking shows how meters themselves are built.
:::

::: play
- A divider of two equal resistors from 10 V, with a voltmeter of input resistance $R_M$ across its output. The meter reads the loaded voltage.
- With $R_M$ = 10 MΩ (a typical multimeter) and 100 kΩ resistors, the reading is half a percent low. Make the resistors 1 MΩ.
- How large must $R_M$ be, compared with the divider's resistors, for an error under 0.1%?
:::
:::

```sim circuit
V1 in 0 10          @ 0,0 down
R1 in out 100k      @ 0,0 right
R2 out 0 100k       @ 2,0 down
RM out 0 10M        @ 4,0 down
slider: RM 10k..100M log
slider: R1 1k..10M log
slider: R2 1k..10M log
scope: v(out)
time: 0..1m s
meter: v(out), i(RM)
```

::: predict
## A 10 MΩ multimeter measures the midpoint of a divider made of two 1 MΩ resistors from 10 V. What does it read?

- [ ] 5.00 V
- [ ] 4.98 V
- [x] 4.76 V
- [ ] 2.50 V

::: reveal
4.76 V. Seen from the midpoint, the divider is a 5 V source behind 1 MΩ ∥ 1 MΩ = 500 kΩ. The meter's 10 MΩ forms a second divider with that: $5 \times \frac{10}{10.5} = 4.76$ V, almost 5% low. The meter told the truth about the circuit with the meter attached.
:::
:::

::: nameit
## Voltmeter loading

A voltmeter is a resistance $R_M$ placed across the two points it measures. Replace the circuit, seen from those points, by its Thevenin equivalent $V_\text{th}$ behind $R_\text{th}$, and the meter reads

$$V_\text{read} = V_\text{th}\frac{R_M}{R_\text{th} + R_M}$$

The relative error is $-\frac{R_\text{th}}{R_\text{th} + R_M} \approx -\frac{R_\text{th}}{R_M}$: keep $R_M$ at least a hundred to a thousand times $R_\text{th}$. Handheld multimeters have about 10 MΩ; an oscilloscope input 1 MΩ, or 10 MΩ through a ×10 probe.

## Ammeter burden

An ammeter is a small resistance $R_A$ (the **burden**) put in series with the branch. With the rest of the circuit as $V_\text{th}$ behind $R_\text{th}$, it reads $\frac{V_\text{th}}{R_\text{th} + R_A}$ instead of $\frac{V_\text{th}}{R_\text{th}}$. A multimeter's current ranges can have ohms of burden, which matters in low-voltage circuits.

## Building meters

A moving-coil meter needs a full-scale current $I_\text{fs}$ through its coil of resistance $R_c$.

- **Voltmeter** for full scale $V$: a series **multiplier** $R_s = \frac{V}{I_\text{fs}} - R_c$. Its sensitivity, $1/I_\text{fs}$ in Ω/V, is the input resistance per volt of range.
- **Ammeter** for full scale $I$: a parallel **shunt** that carries the rest, $R_\text{sh} = \frac{R_cI_\text{fs}}{I - I_\text{fs}}$.

Digital meters work the same way inside: a voltage range is a resistor divider, and a current range is a known shunt whose voltage is measured.

## Small resistances

Measuring a fraction of an ohm with two leads adds the leads' resistance to the reading. A **four-wire** (Kelvin) measurement sends current through one pair of leads and senses voltage with another pair that carries almost no current, so the lead resistance drops out.
:::

::: example
## A 10 MΩ meter measures the midpoint of a 100 kΩ/100 kΩ divider from 10 V, and then of a 1 MΩ/1 MΩ divider. What does it read each time?

::: solution
1. **Thevenin equivalents.** The two dividers are 5 V behind 50 kΩ and 5 V behind 500 kΩ.
2. **Reading on the 100 kΩ divider.**
   $$\begin{aligned} v &= 5 \times \frac{10}{10.05} \\ &= 4.975\ \text{V} \end{aligned}$$
   0.5% low.
3. **Reading on the 1 MΩ divider.**
   $$\begin{aligned} v &= 5 \times \frac{10}{10.5} \\ &= 4.76\ \text{V} \end{aligned}$$
   4.8% low.

**Answer:** the meter reads 4.975 V on the 100 kΩ divider and 4.76 V on the 1 MΩ one.
:::
:::

::: example
## A meter movement needs 1 mA for full scale and has a 50 Ω coil. Turn it into a 10 V voltmeter and a 1 A ammeter.

::: solution
1. **Voltmeter.** Add a resistor in series with the coil:
   $$\begin{aligned} R_s &= \frac{10}{10^{-3}} - 50 \\ &= 9950\ \Omega \end{aligned}$$
   This gives an input resistance of 10 kΩ (1000 Ω/V).
2. **Ammeter.** Add a shunt in parallel with the coil:
   $$\begin{aligned} R_\text{sh} &= \frac{50 \times 10^{-3}}{1 - 10^{-3}} \\ &= 0.05005\ \Omega \end{aligned}$$
   It carries 999 mA while the coil carries 1 mA.

**Answer:** 9950 Ω in series makes the 10 V voltmeter, and a 0.05005 Ω shunt in parallel makes the 1 A ammeter.
:::
:::

::: example
## An analog meter rated 20 kΩ/V is set to its 10 V range and measures the midpoint of a 100 kΩ/100 kΩ divider from 10 V. What does it read?

::: solution
1. **Meter resistance.** On the 10 V range,
   $$\begin{aligned} R_m &= 20\ \text{k}\Omega/\text{V} \times 10\ \text{V} \\ &= 200\ \text{k}\Omega \end{aligned}$$
2. **Thevenin equivalent of the divider.** The midpoint is 5 V behind
   $$100\,\|\,100 = 50\ \text{k}\Omega$$
3. **Reading.**
   $$\begin{aligned} v &= 5 \times \frac{200}{50 + 200} \\ &= 4.0\ \text{V} \end{aligned}$$
   20% low.
4. **Compare with a digital meter.** A 10 MΩ digital meter would read 4.98 V.
5. **Why manuals named the meter.** Old service manuals listed voltages "measured with a 20 kΩ/V meter" for exactly this reason: the reading depends on the meter as much as the circuit.

**Answer:** the meter reads 4.0 V, 20% low.
:::
:::

::: check
given: Vth = 5 | 12; Rth = 50 | 200 | 1000; RM = 1 | 10
answer: Vth*RM*1000/(Rth + RM*1000)
unit: V
tolerance: 0.1%

## A point has a Thevenin equivalent of {Vth} V behind {Rth} kΩ. A meter with {RM} MΩ input resistance measures it. What does it read?

::: right
Right. $V_\text{th}\frac{R_M}{R_\text{th} + R_M}$ = {answer}.
:::

::: misses
- [Vth] That's the unloaded voltage; the meter's resistance forms a divider with $R_\text{th}$.
- [any] Not yet. Divider of $R_\text{th}$ and $R_M$.
:::
:::

::: check
given: R = 10 | 100 | 1000; RM = 1 | 10
answer: 100*(R/2)/(R/2 + RM*1000)
tolerance: 0.5%

## A divider of two {R} kΩ resistors is measured at its midpoint by a {RM} MΩ meter. By what percentage does the reading fall short?

::: right
Right. $R_\text{th} = R/2$, and the shortfall is $\frac{R_\text{th}}{R_\text{th} + R_M}$ = {answer}%.
:::

::: misses
- [100*R/(R + RM*1000)] The Thevenin resistance at the midpoint is $R \parallel R = R/2$.
- [any] Not yet. Find $R_\text{th}$, then the divider with $R_M$.
:::
:::

::: check
given: V = 1 | 3.3; R = 10 | 100; Ra = 1 | 10
answer: V/(R + Ra)*1000
unit: mA
tolerance: 0.5%

## A {V} V source drives {R} Ω. An ammeter with {Ra} Ω of burden is put in series. What does it read?

::: right
Right. $\frac{V}{R + R_A}$ = {answer}.
:::

::: misses
- [V/R*1000] The ammeter's own resistance adds to the circuit.
- [any] Not yet. Include the burden in series.
:::
:::

::: check
given: Ifs = 0.05 | 1; Rc = 50 | 2000; I = 2 | 5
answer: Rc*Ifs/(I - Ifs)
unit: Ω
tolerance: 0.5%

## A movement needs {Ifs} mA for full scale and has a {Rc} Ω coil. What shunt turns it into a {I} mA ammeter?

::: right
Right. $\frac{R_cI_\text{fs}}{I - I_\text{fs}}$ = {answer}.
:::

::: misses
- [Rc*Ifs/I] The shunt carries the total minus the coil's share, $I - I_\text{fs}$.
- [any] Not yet. Shunt and coil share the same voltage, $R_cI_\text{fs}$.
:::
:::

::: check
given: Rc = 50 | 100 | 200; V = 0.5 | 1 | 2
answer: V/0.001 - Rc
unit: Ω
tolerance: 0.5%

## A movement needs 1 mA for full scale and has a {Rc} Ω coil. What series resistor makes a {V} V voltmeter?

::: right
Right. $\frac{V}{I_\text{fs}} - R_c$ = {answer}.
:::

::: misses
- [V/0.001] Subtract the coil's own resistance.
- [any] Not yet. The total resistance must be $V/I_\text{fs}$.
:::
:::

::: check
given: R = 0.05 | 0.1 | 0.5; Rl = 0.02 | 0.1
answer: 100*2*Rl/R
tolerance: 0.5%

## A {R} Ω resistor is measured with two leads of {Rl} Ω each. By what percentage does the reading come out high?

::: right
Right. The leads add $2R_\text{lead}$: {answer}%. A four-wire measurement removes it.
:::

::: misses
- [100*Rl/R] Both leads are in the path.
- [any] Not yet. The meter sees $R + 2R_\text{lead}$.
:::
:::

::: check
kind: parts
given: s = 1 | 20 | 50; r = 2.5 | 10; R = 10 | 100

## An analog meter rated {s} kΩ/V is on its {r} V range, measuring the midpoint of an {R} kΩ / {R} kΩ divider from {r} V.

::: part
answer: s*r
unit: kΩ
tolerance: 0.5%

### What's the meter's resistance?

::: misses
- [any] Sensitivity times range.
:::
:::

::: part
answer: r/2*s*r/(R/2 + s*r)
unit: V
tolerance: 0.5%

### What does it read?

::: misses
- [r/2] The meter loads the divider.
- [any] Thevenin: $\frac{V}{2}$ behind $\frac R2$.
:::
:::
:::

::: check
kind: derivation
vars: V = 0.1..100, R = 0.01..1000, M = 1..10000

## A point is V behind R (kΩ), measured by a meter of M (kΩ).

::: step
answer: V*M/(R + M)

### What does the meter read?
:::

::: step
answer: R/(R + M)

### What fraction low is the reading?
:::

::: right
Right. The error is the ratio of source resistance to total, so a meter needs to be much larger than what it measures.
:::
:::

::: explain
## Why does an oscilloscope probe often have a ×10 setting, when it makes signals ten times smaller on the screen?

::: model
On its own, a scope input is about 1 MΩ, which loads high-impedance circuits noticeably. A ×10 probe puts a 9 MΩ resistor in series with the input, so the circuit sees 10 MΩ, ten times less loading. The cost is that the probe and input form a 10:1 divider, so the signal arrives a tenth as large, and the scope multiplies its display by ten to compensate. The same idea applies at high frequencies, where the probe also presents less capacitance to the circuit.
:::
:::

::: practice

::: check
given: Ifs = 0.02 | 0.05 | 1
answer: 1/(Ifs/1000)
unit: Ω/V
tolerance: 0.5%

## A movement needs {Ifs} mA for full scale. What is its sensitivity, in Ω per volt?

::: misses
- [any] $1/I_\text{fs}$.
:::
:::

::: check
given: Ra = 10 | 47; Rb = 10 | 100
answer: Ra*Rb/(Ra + Rb)
unit: kΩ
tolerance: 0.5%

## A divider has {Ra} kΩ on top and {Rb} kΩ on the bottom. What is its Thevenin resistance at the midpoint?

::: misses
- [any] The two in parallel.
:::
:::

::: check
given: Rth = 1 | 10 | 100; e = 0.1 | 1
answer: Rth*(100/e - 1)/1000
unit: MΩ
tolerance: 0.5%

## A point has a Thevenin resistance of {Rth} kΩ. What meter resistance keeps the reading within {e}% of the truth?

::: misses
- [any] Solve $\frac{R_\text{th}}{R_\text{th} + R_M} = e$.
:::
:::
:::