title: Thevenin and Norton
heading: Any two terminals look like a source and one resistor
eyebrow: C1 · Lesson 15 · Thevenin and Norton
xp: 50
---

::: hook
Behind two terminals there might be a dozen resistors and three sources. Yet from the outside, any linear circuit behaves exactly like one voltage source in series with one resistor. Two measurements pin both down. This is the most useful idea in circuit analysis: it's how engineers think about a sensor's output, an amplifier's input, a power supply or a battery, and it's why "output resistance" and "input resistance" are things you can put on a datasheet.

::: play
- The network on the left is a black box with terminals at node out. You can change the load $R_L$ and read the output.
- Make $R_L$ very large and note the voltage: that's the open-circuit voltage. Now make $R_L$ very small and note the current: that's the short-circuit current.
- Divide one by the other. Then set $R_L$ to that value. What happens to the output voltage?
:::
:::

```sim circuit
V1 in 0 12          @ 0,0 down
R1 in a 2k          @ 0,0 right
R2 a 0 6k           @ 2,0 down
R3 a out 1.5k       @ 2,0 right
RL out 0 3k         @ 4,0 down
slider: RL 1..1M log
scope: v(out)
time: 0..1m s
meter: v(out), i(RL)
```

::: predict
## A black box reads 6 V with no load and delivers 2 mA into a short circuit. What will it read with a 3 kΩ load?

- [ ] 6 V
- [x] 3 V
- [ ] 2 V
- [ ] 4 V

::: reveal
3 V. The box acts as 6 V in series with $R_\text{th} = 6/0.002 = 3$ kΩ. A 3 kΩ load makes an even divider, so half the voltage reaches it. Two measurements of the box predict its behavior with every possible load.
:::
:::

::: nameit
## Thevenin's and Norton's theorems

**Thevenin.** Any linear network of resistors and sources, seen from two terminals, is equivalent to a voltage source $V_\text{th}$ in series with a resistance $R_\text{th}$:

- $V_\text{th}$ is the **open-circuit voltage** at the terminals;
- $R_\text{th}$ is the resistance seen looking in with every independent source switched off (voltage sources replaced by shorts, current sources by open circuits);
- equivalently, $R_\text{th} = V_\text{oc}/I_\text{sc}$.

**Norton.** The same network is equally a current source $I_\text{N} = V_\text{th}/R_\text{th}$ (the short-circuit current) in parallel with $R_\text{th}$. The two are related by source transformation (lesson 14).

**Why it works.** In a linear circuit, the terminal voltage is a linear function of the terminal current: $v = V_\text{oc} - R_\text{th}\,i$. A straight line is fixed by two points, and the Thevenin circuit has exactly that line.

**For the circuit above:** with the load removed, $R_3$ carries no current, so $V_\text{th}$ is the divider voltage $12 \times 6/(2 + 6) = 9$ V. Shorting the source, $R_\text{th} = R_3 + R_1 \parallel R_2 = 1.5 + 1.5 = 3$ kΩ.

**Using it.** To find the current in one part of a big circuit, replace everything else by its Thevenin equivalent. To see how a load affects a source, compare $R_L$ with $R_\text{th}$. Engineers call $R_\text{th}$ the **output resistance** (or output impedance) of a source and the input resistance of whatever it drives: a source with low output resistance driving a load with high input resistance passes its voltage on almost unchanged.

**Measuring it** on a real circuit: shorting the output may damage it, so instead measure $V_\text{oc}$, then the voltage $v$ with a known load, and use $R_\text{th} = R_L(V_\text{oc}/v - 1)$.
:::

::: example
## 10 V drives a 4 kΩ over 6 kΩ divider, and 1.6 kΩ connects the midpoint to the output. Find the Thevenin equivalent and the voltage across a 4 kΩ load.

::: solution
1. **Thevenin voltage.**
   $$\begin{aligned} V_\text{th} &= 10 \times \frac{6}{10} \\ &= 6\ \text{V} \end{aligned}$$
2. **Thevenin resistance.**
   $$\begin{aligned} R_\text{th} &= 4 \parallel 6 + 1.6 \\ &= 2.4 + 1.6 \\ &= 4\ \text{k}\Omega \end{aligned}$$
3. **Load voltage.** A 4 kΩ load gets half: 3 V.

**Answer:** the Thevenin equivalent is 6 V behind 4 kΩ, and the 4 kΩ load gets 3 V.
:::
:::

::: example
## A sensor output reads 5 V open-circuit and 25 mA short-circuit. What are its Thevenin and Norton equivalents?

::: solution
1. **Thevenin resistance.**
   $$\begin{aligned} R_\text{th} &= \frac{5}{0.025} \\ &= 200\ \Omega \end{aligned}$$
2. **The two equivalents.** Thevenin is 5 V behind 200 Ω, and Norton is 25 mA with 200 Ω in parallel.

**Answer:** Thevenin is 5 V behind 200 Ω, and Norton is 25 mA with 200 Ω in parallel.
:::
:::

::: example
## A bridge runs from 10 V: one side is 1 kΩ over 1 kΩ, the other 1 kΩ over 1.1 kΩ. Find the Thevenin equivalent between the two midpoints, and what a 10 kΩ meter across them reads.

::: solution
1. **Midpoint voltages.** Open-circuit, one midpoint sits at 5 V and the other at
   $$10 \times \frac{1.1}{2.1} = 5.238\ \text{V}$$
2. **Thevenin voltage.**
   $$\begin{aligned} V_{th} &= 5.238 - 5 \\ &= 0.238\ \text{V} \end{aligned}$$
3. **Thevenin resistance.** With the source shorted, each side's resistors are in parallel, and the two sides are in series between the midpoints:
   $$\begin{aligned} R_{th} &= 1\,\|\,1 + 1\,\|\,1.1 \\ &= 0.5 + 0.524 \\ &= 1.024\ \text{k}\Omega \end{aligned}$$
4. **Meter reading.**
   $$\begin{aligned} v &= 0.238 \times \frac{10}{11.024} \\ &= 0.216\ \text{V} \end{aligned}$$
   9% low.
5. **Bridge amplifiers.** They have input resistances of megohms for this reason.

**Answer:** the Thevenin equivalent is 0.238 V behind 1.024 kΩ, and the 10 kΩ meter reads 0.216 V.
:::
:::

::: check
given: Vs = 10 | 12 | 24; R1 = 1 | 2 | 3; R2 = 4 | 6
answer: Vs*R2/(R1 + R2)
unit: V
tolerance: 0.5%

## A {Vs} V source feeds $R_1$ = {R1} kΩ in series with $R_2$ = {R2} kΩ to ground. The terminals are across $R_2$. What is $V_\text{th}$?

::: right
Right. The open-circuit voltage is the divider's output: {answer}.
:::

::: misses
- [Vs] Some of the voltage drops across R1.
- [Vs*R1/(R1 + R2)] That's across R1.
- [any] Not yet. Find the voltage across $R_2$ with nothing connected.
:::
:::

::: check
given: R1 = 1 | 2 | 3; R2 = 4 | 6; R3 = 0.5 | 1.5
answer: R3 + R1*R2/(R1 + R2)
unit: kΩ
tolerance: 0.5%

## The same divider ($R_1$ = {R1} kΩ, $R_2$ = {R2} kΩ) has a series resistor $R_3$ = {R3} kΩ between its output and the terminal. What is $R_\text{th}$?

::: right
Right. Short the source: $R_3 + R_1 \parallel R_2$ = {answer}.
:::

::: misses
- [R1 + R2 + R3] With the source shorted, R1 and R2 are in parallel.
- [R1*R2/(R1 + R2)] Add R3, which is in series with the terminal.
- [any] Not yet. Turn off the source and combine what's left.
:::
:::

::: check
given: Vth = 5 | 9 | 12; Rth = 1 | 2.2 | 4.7; RL = 3.3 | 10 | 22
answer: Vth*RL/(Rth + RL)
unit: V
tolerance: 0.5%

## A source has $V_\text{th}$ = {Vth} V and $R_\text{th}$ = {Rth} kΩ. What voltage does a {RL} kΩ load see?

::: right
Right. A divider of $R_\text{th}$ and $R_L$: {answer}.
:::

::: misses
- [Vth] Some voltage drops across $R_\text{th}$.
- [Vth*Rth/(Rth + RL)] That's the drop inside the source.
- [any] Not yet. $v = V_\text{th}R_L/(R_\text{th} + R_L)$.
:::
:::

::: check
given: Voc = 3 | 5 | 9; Isc = 0.5 | 2 | 4
answer: Voc/Isc
unit: kΩ
tolerance: 0.5%

## A network reads {Voc} V open-circuit and delivers {Isc} mA into a short. What is its Thevenin resistance?

::: right
Right. $R_\text{th} = V_\text{oc}/I_\text{sc}$ = {answer}.
:::

::: misses
- [Voc*Isc] Divide the voltage by the current.
- [any] Not yet. $R_\text{th} = V_\text{oc}/I_\text{sc}$.
:::
:::

::: check
given: Vth = 6 | 10 | 15; Rth = 2 | 5 | 8
answer: Vth/Rth
unit: mA
tolerance: 0.5%

## A source has $V_\text{th}$ = {Vth} V and $R_\text{th}$ = {Rth} kΩ. What is its Norton current?

::: right
Right. $I_\text{N} = V_\text{th}/R_\text{th}$ = {answer}, with {Rth} kΩ in parallel.
:::

::: misses
- [Vth*Rth] Divide the voltage by the resistance.
- [any] Not yet. The Norton current is the short-circuit current.
:::
:::

::: check
kind: parts
given: x = 1.05 | 1.1 | 1.2; L = 10 | 100

## A bridge from 10 V has 1 kΩ over 1 kΩ on one side and 1 kΩ over {x} kΩ on the other.

::: part
answer: 10*(x/(1 + x) - 0.5)
unit: V
tolerance: 0.5%

### What's its Thevenin voltage between the midpoints?

::: misses
- [any] Difference of the two divider outputs.
:::
:::

::: part
answer: 10*(x/(1 + x) - 0.5)*L/(L + 0.5 + x/(1 + x))
unit: V
tolerance: 0.5%

### What does a {L} kΩ meter across them read?

::: misses
- [10*(x/(1 + x) - 0.5)] The bridge's Thevenin resistance loads the reading.
- [any] $R_{th} = 1\,\|\,1 + 1\,\|\,x$.
:::
:::
:::

::: check
kind: derivation
vars: V = 0.1..100, I = 0.01..100, L = 0.01..1000

## A network reads V open-circuit and I into a short (mA, kΩ).

::: step
answer: V/I

### What's its Thevenin resistance?
:::

::: step
answer: V*L/(V/I + L)

### What voltage does a load L get?
:::

::: step
answer: (V*L/(V/I + L))^2/L

### What power does it absorb, in mW?
:::

::: right
Right. Two measurements, open and short, fix a linear network completely.
:::
:::

::: explain
## Why can the whole of a linear circuit, seen from two terminals, be replaced by one source and one resistor?

::: model
In a linear circuit, every voltage and current depends linearly on the sources and on whatever current is drawn from the terminals. So the terminal voltage is a straight-line function of the terminal current: the open-circuit voltage minus some constant times the current. A single voltage source in series with a single resistor has exactly that straight-line behavior, and choosing its voltage as the open-circuit voltage and its resistance as the slope makes the two indistinguishable to anything connected outside.
:::
:::

::: practice

::: check
given: Vth = 5 | 12; Rth = 1 | 3; RL = 2 | 4
answer: Vth/(Rth + RL)
unit: mA
tolerance: 0.5%

## $V_\text{th}$ = {Vth} V, $R_\text{th}$ = {Rth} kΩ, load {RL} kΩ. Load current?

::: misses
- [Vth/RL] Include $R_\text{th}$ in the loop.
- [any] $V_\text{th}/(R_\text{th} + R_L)$.
:::
:::

::: check
given: IN = 1 | 2 | 5; RN = 2 | 3
answer: IN*RN
unit: V
tolerance: 0.5%

## A Norton source of {IN} mA with {RN} kΩ in parallel. Its Thevenin voltage?

::: misses
- [IN/RN] Multiply.
- [any] $V_\text{th} = I_\text{N}R_\text{th}$.
:::
:::

::: check
given: R1 = 2 | 4; R2 = 6 | 12
answer: R1*R2/(R1 + R2)
unit: kΩ
tolerance: 0.5%

## A divider of {R1} kΩ and {R2} kΩ, driven by an ideal source. Its Thevenin resistance?

::: misses
- [R1 + R2] They're in parallel once the source is shorted.
- [any] $R_1 \parallel R_2$.
:::
:::
:::