C10 · Lesson 17 · Broadband matching
Multi-section transformers, and the limit no network can beat
A single quarter-wave transformer matches perfectly at one frequency and drifts off on either side. Many systems need a match across an octave or more: a wideband antenna feed, a cable-TV distribution amplifier, a test fixture. Splitting the impedance step into several smaller steps, each a quarter wave long, spreads the match across a wide band. And for loads with stored energy, a theorem says how good any match can possibly be.
- The curves are the reflection from transformers matching 50 Ω to a resistive load R, against frequency relative to the design frequency : one quarter-wave section, and binomial designs of two and three sections.
- At all are perfect. The binomial designs are flat at the center: their reflection grows as , so more sections keep it low over a wider band.
- Raise R: the bigger the impedance step, the higher every curve rises off-center, and the more sections it takes to cover the same band.
Predict
A quarter-wave transformer matches 100 Ω to 50 Ω at 1 GHz. Over roughly what band does it keep |Γ| below 0.1?
About 37%: from roughly 0.82 to 1.18 GHz. With a two-section binomial design, |Γ| < 0.1 holds over about 74%, and with three sections, about 93%. More sections cost length and loss, but buy bandwidth.
Name it
One section
A quarter-wave section of impedance matches exactly at the frequency where it's λ/4 long. With its reflection is
and the fractional band where it stays below is
Several sections
Split the step into N quarter-wave sections. In the binomial (maximally flat) design the small reflections at the N + 1 steps are in binomial proportions, so the total is
with section impedances from . Its band for is . A Chebyshev design lets Γ ripple up to across the band in exchange for a wider band with the same N.
The Bode–Fano limit
A load with reactance, such as a resistor R in parallel with a capacitor C, can't be matched over a wide band by any lossless network. Bode and Fano showed
so a constant reflection over a band Δω needs . A perfect match (Γ = 0) is only possible at isolated frequencies; a wider band forces a worse match.
Worked example
A quarter-wave transformer matches 100 Ω to 50 Ω. Over what fractional band is |Γ| below 0.1?
Show the solution
- Section impedance.
- Argument of the arccos. and rad.
- Fractional band. from about 0.82 to 1.18 .
Answer |Γ| stays below 0.1 over a 36.7% band, from about 0.82 to 1.18 .
Worked example
Design a two-section binomial transformer from 50 Ω to 100 Ω, and find its band for |Γ| < 0.05.
Show the solution
- Total log step.
- First section. so Ω.
- Second section. so Ω, and one more step of reaches 100 Ω.
- The constant A.
- The arccos argument.
- The band. a 50.6% band at a tighter Γ than the single section's 0.1.
Answer = 59.5 Ω and = 84.1 Ω, holding |Γ| < 0.05 over a 50.6% band.
Worked example
A load is 50 Ω in parallel with 2 pF (RC = 100 ps). What is the best reflection any lossless network can hold from 1 to 4 GHz?
Show the solution
- Bandwidth in radians per second.
- The Bode-Fano limit.
- Best reflection.
- A narrower band. Narrowing it to 1 GHz wide would allow 0.0067.
Answer no network does better than |Γ| = 0.19 across 1 to 4 GHz.
Check
A quarter-wave transformer matches 25 Ω to 50 Ω at 2.4 GHz on a line with = 3.3.
(a)
What impedance must the section have?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
How long is it?
Check
A single quarter-wave section matches 100 Ω to 50 Ω.
(a)
Over what fractional band does |Γ| stay below 0.05?
(b)
What is |Γ| at the band's far ends, where the section is 0 or λ/2 long?
Check
A two-section binomial transformer matches 50 Ω to 150 Ω.
(a)
What is the first section's impedance, next to the 50 Ω line?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
And the second?
Check
An N-section binomial transformer (N = 2) matches 50 Ω to 100 Ω, used at 1.3 times its design frequency.
(a)
What is |Γ| there, by the small-reflection formula?
(b)
What return loss is that?
Check
A load is 50 Ω in parallel with 1 pF, to be matched over a 3 GHz band.
(a)
What is the largest any lossless network can hold?
(b)
What is the smallest constant |Γ| possible?
Check
The Bode–Fano limit for a parallel RC load, with a constant reflection g over a band Δω and total reflection outside it.
Step 1
What does equal inside the band?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is the widest band Δω that allows reflection g?
Check
A designer needs the widest band from a three-section transformer and can tolerate a small ripple in |Γ| across it. Which design?
Check
Write binomial_bandwidth(Z0, ZL, N, gm): the fractional band (as a fraction) over which an N-section binomial transformer keeps |Γ| below gm, using .
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why does splitting an impedance step into several quarter-wave sections widen the band?
At the design frequency each section is a quarter wave long, so the reflections from successive steps arrive back with half-wave path differences and cancel. Off the design frequency the cancellation is imperfect, and how fast it degrades depends on how big the individual reflections are and how they're arranged. With several small steps, each reflection is small, and their binomial or Chebyshev weights make the leftover sum grow slowly away from the center: the binomial design's error goes as a high power of , staying near zero over a wide region. A single big step has one large reflection that can be cancelled only near one frequency. More sections means more small reflections that can be arranged to cancel over more frequencies.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.