title: Broadband matching
heading: Multi-section transformers, and the limit no network can beat
eyebrow: C10 · Lesson 17 · Broadband matching
xp: 40
---

::: hook
A single quarter-wave transformer matches perfectly at one frequency and drifts off on either side. Many systems need a match across an octave or more: a wideband antenna feed, a cable-TV distribution amplifier, a test fixture. Splitting the impedance step into several smaller steps, each a quarter wave long, spreads the match across a wide band. And for loads with stored energy, a theorem says how good any match can possibly be.
:::

::: play
- The curves are the reflection from transformers matching 50 Ω to a resistive load R, against frequency relative to the design frequency $f_0$: one quarter-wave section, and binomial designs of two and three sections.
- At $f_0$ all are perfect. The binomial designs are flat at the center: their reflection grows as $\cos^N\theta$, so more sections keep it low over a wider band.
- Raise R: the bigger the impedance step, the higher every curve rises off-center, and the more sections it takes to cover the same band.
:::

```sim plot
view: graph
x: x = 0..2
y: G = 0..0.6
slider: R = 60..400 step 5 = 100
plot: 1/sqrt(1 + (2*sqrt(50*R)/(R - 50)/cos(pi*x/2))^2) | samples: 600 | label: one section (exact)
plot: abs((R - 50)/(R + 50))*abs(cos(pi*x/2))^2 | samples: 600 | label: two-section binomial
plot: abs((R - 50)/(R + 50))*abs(cos(pi*x/2))^3 | samples: 600 | label: three-section binomial
readout: reflection of the bare load = (R - 50)/(R + 50) | digits: 3
```

::: predict
## A quarter-wave transformer matches 100 Ω to 50 Ω at 1 GHz. Over roughly what band does it keep |Γ| below 0.1?

- [ ] 5% of 1 GHz
- [x] About 37%
- [ ] About 100%
- [ ] Only at exactly 1 GHz

::: reveal
About 37%: from roughly 0.82 to 1.18 GHz. With a two-section binomial design, |Γ| < 0.1 holds over about 74%, and with three sections, about 93%. More sections cost length and loss, but buy bandwidth.
:::
:::

::: nameit
## One section

A quarter-wave section of impedance $Z_1 = \sqrt{Z_0Z_L}$ matches exactly at the frequency where it's λ/4 long. With $\theta = \frac{\pi}{2}\frac{f}{f_0}$ its reflection is

$$\lvert\Gamma\rvert = \left[1 + \left(\frac{2\sqrt{Z_0Z_L}}{Z_L - Z_0}\sec\theta\right)^2\right]^{-1/2}$$

and the fractional band where it stays below $\Gamma_m$ is

$$\frac{\Delta f}{f_0} = 2 - \frac4\pi\arccos\!\left[\frac{\Gamma_m}{\sqrt{1 - \Gamma_m^2}}\cdot\frac{2\sqrt{Z_0Z_L}}{\lvert Z_L - Z_0\rvert}\right]$$

## Several sections

Split the step into N quarter-wave sections. In the **binomial** (maximally flat) design the small reflections at the N + 1 steps are in binomial proportions, so the total is

$$\Gamma(\theta) \approx 2^NA\cos^N\theta\,e^{-jN\theta}, \qquad A = 2^{-N}\frac{Z_L - Z_0}{Z_L + Z_0}$$

with section impedances from $\ln Z_{n+1} = \ln Z_n + 2^{-N}\binom{N}{n}\ln(Z_L/Z_0)$. Its band for $\Gamma_m$ is $\frac{\Delta f}{f_0} = 2 - \frac4\pi\arccos\left[\tfrac12(\Gamma_m/\lvert A\rvert)^{1/N}\right]$. A **Chebyshev** design lets Γ ripple up to $\Gamma_m$ across the band in exchange for a wider band with the same N.

## The Bode–Fano limit

A load with reactance, such as a resistor R in parallel with a capacitor C, can't be matched over a wide band by any lossless network. Bode and Fano showed

$$\int_0^\infty \ln\frac{1}{\lvert\Gamma(\omega)\rvert}\,d\omega \le \frac{\pi}{RC}$$

so a constant reflection $\Gamma_m$ over a band Δω needs $\Delta\omega\ln(1/\Gamma_m) \le \pi/RC$. A perfect match (Γ = 0) is only possible at isolated frequencies; a wider band forces a worse match.
:::

::: example
## A quarter-wave transformer matches 100 Ω to 50 Ω. Over what fractional band is |Γ| below 0.1?

::: solution
1. **Section impedance.**
   $$\begin{aligned} Z_1 &= \sqrt{5000} \\ &= 70.7\ \Omega \end{aligned}$$
2. **Argument of the arccos.**
   $$\frac{0.1}{0.995}\cdot\frac{2 \times 70.7}{50} = 0.284$$
   and $\arccos 0.284 = 1.283$ rad.
3. **Fractional band.**
   $$\begin{aligned} \frac{\Delta f}{f_0} &= 2 - \frac4\pi(1.283) \\ &= 0.367 \end{aligned}$$
   from about 0.82 to 1.18 $f_0$.

**Answer:** |Γ| stays below 0.1 over a 36.7% band, from about 0.82 to 1.18 $f_0$.
:::
:::

::: example
## Design a two-section binomial transformer from 50 Ω to 100 Ω, and find its band for |Γ| < 0.05.

::: solution
1. **Total log step.**
   $$\ln\frac{100}{50} = 0.693$$
2. **First section.**
   $$\ln Z_1 = \ln 50 + \tfrac14(0.693)$$
   so $Z_1 = 59.5$ Ω.
3. **Second section.**
   $$\ln Z_2 = \ln Z_1 + \tfrac24(0.693)$$
   so $Z_2 = 84.1$ Ω, and one more step of $\tfrac14(0.693)$ reaches 100 Ω.
4. **The constant A.**
   $$\begin{aligned} A &= \tfrac14 \times \frac{50}{150} \\ &= 0.0833 \end{aligned}$$
5. **The arccos argument.**
   $$\tfrac12\left(\frac{0.05}{0.0833}\right)^{1/2} = 0.387$$
6. **The band.**
   $$\begin{aligned} \frac{\Delta f}{f_0} &= 2 - \frac4\pi\arccos 0.387 \\ &= 0.506 \end{aligned}$$
   a 50.6% band at a tighter Γ than the single section's 0.1.

**Answer:** $Z_1$ = 59.5 Ω and $Z_2$ = 84.1 Ω, holding |Γ| < 0.05 over a 50.6% band.
:::
:::

::: example
## A load is 50 Ω in parallel with 2 pF (RC = 100 ps). What is the best reflection any lossless network can hold from 1 to 4 GHz?

::: solution
1. **Bandwidth in radians per second.**
   $$\begin{aligned} \Delta\omega &= 2\pi \times 3\ \text{GHz} \\ &= 1.885 \times 10^{10}\ \text{rad/s} \end{aligned}$$
2. **The Bode-Fano limit.**
   $$\begin{aligned} \ln\frac{1}{\Gamma_m} &\le \frac{\pi}{RC\,\Delta\omega} \\ &= \frac{\pi}{10^{-10} \times 1.885 \times 10^{10}} \\ &= 1.667 \end{aligned}$$
3. **Best reflection.**
   $$\begin{aligned} \Gamma_m &\ge e^{-1.667} \\ &= 0.19 \end{aligned}$$
4. **A narrower band.** Narrowing it to 1 GHz wide would allow 0.0067.

**Answer:** no network does better than |Γ| = 0.19 across 1 to 4 GHz.
:::
:::

::: check
kind: parts
given: Z0 = 50 | 75; ZL = 25 | 150 | 300; f = 1 | 2.4; e = 1 | 3.3

## A quarter-wave transformer matches {ZL} Ω to {Z0} Ω at {f} GHz on a line with $\varepsilon_\text{eff}$ = {e}.

::: part
answer: sqrt(Z0*ZL)
unit: Ω
tolerance: 0.5%

### What impedance must the section have?

::: misses
- [any] $\sqrt{Z_0Z_L}$.
:::
:::

::: part
answer: 29.98/(f*sqrt(e))/4
unit: cm
tolerance: 0.5%

### How long is it?

::: misses
- [any] λ/4 on the line.
:::
:::
:::

::: check
kind: parts
given: Z0 = 50; ZL = 75 | 100 | 200; g = 0.05 | 0.1 | 0.15

## A single quarter-wave section matches {ZL} Ω to 50 Ω.

::: part
answer: (2 - 4/pi*acos(g/sqrt(1 - g^2)*2*sqrt(Z0*ZL)/abs(ZL - Z0)))*100
unit: %
tolerance: 0.5%

### Over what fractional band does |Γ| stay below {g}?

::: misses
- [any] The single-section bandwidth formula.
:::
:::

::: part
answer: abs((ZL - Z0)/(ZL + Z0))
tolerance: 0.5%

### What is |Γ| at the band's far ends, where the section is 0 or λ/2 long?

::: misses
- [any] The bare load's reflection.
:::
:::
:::

::: check
kind: parts
given: ZL = 100 | 150 | 400

## A two-section binomial transformer matches 50 Ω to {ZL} Ω.

::: part
answer: exp(ln(50) + ln(ZL/50)/4)
unit: Ω
tolerance: 0.5%

### What is the first section's impedance, next to the 50 Ω line?

::: misses
- [any] $\ln Z_1 = \ln 50 + \tfrac14\ln(Z_L/50)$.
:::
:::

::: part
answer: exp(ln(50) + 3*ln(ZL/50)/4)
unit: Ω
tolerance: 0.5%

### And the second?

::: misses
- [any] Add $\tfrac24$ of the log step to $\ln Z_1$.
:::
:::
:::

::: check
kind: parts
given: ZL = 100 | 200; N = 2 | 3 | 4; x = 0.7 | 1.3

## An N-section binomial transformer (N = {N}) matches 50 Ω to {ZL} Ω, used at {x} times its design frequency.

::: part
answer: abs((ZL - 50)/(ZL + 50))*abs(cos(pi*x/2))^N
tolerance: 1%

### What is |Γ| there, by the small-reflection formula?

::: misses
- [any] $\lvert\Gamma_0\rvert\,\lvert\cos\theta\rvert^N$ with $\theta = \frac\pi2\frac f{f_0}$.
:::
:::

::: part
answer: -20*log(abs((ZL - 50)/(ZL + 50))*abs(cos(pi*x/2))^N)
unit: dB
tolerance: 1%

### What return loss is that?

::: misses
- [any] $-20\log_{10}\lvert\Gamma\rvert$.
:::
:::
:::

::: check
kind: parts
given: R = 25 | 50 | 100; C = 1 | 2 | 5; B = 0.5 | 1 | 3

## A load is {R} Ω in parallel with {C} pF, to be matched over a {B} GHz band.

::: part
answer: pi/(R*C*1e-12*2*pi*B*1e9)
tolerance: 0.5%

### What is the largest $\ln(1/\Gamma_m)$ any lossless network can hold?

::: misses
- [any] $\pi/(RC\,\Delta\omega)$.
:::
:::

::: part
answer: exp(-pi/(R*C*1e-12*2*pi*B*1e9))
tolerance: 0.5%

### What is the smallest constant |Γ| possible?

::: misses
- [any] $e^{-\pi/(RC\Delta\omega)}$.
:::
:::
:::

::: check
kind: derivation
vars: R = 1..1000, C = 1e-13..1e-9, g = 0.001..0.9

## The Bode–Fano limit for a parallel RC load, with a constant reflection g over a band Δω and total reflection outside it.

::: step
answer: ln(1/g)

### What does $\ln(1/\lvert\Gamma\rvert)$ equal inside the band?
:::

::: step
answer: pi/(R*C*ln(1/g))

### What is the widest band Δω that allows reflection g?
:::

::: right
Right. A better match, smaller g, shrinks the band in proportion to $1/\ln(1/g)$.
:::
:::

::: check
kind: choice

## A designer needs the widest band from a three-section transformer and can tolerate a small ripple in |Γ| across it. Which design?

- [ ] Binomial
- [x] Chebyshev
- [ ] A single section with a higher impedance
- [ ] Three identical sections of $\sqrt{Z_0Z_L}$

::: misses
- [1] Binomial is maximally flat at the center, which spends its sections on flatness rather than width.
- [3] One section has the narrowest band of all.
- [4] Identical sections don't step the impedance gradually; they make a mismatch at both ends.
:::
:::

::: check
kind: python

## Write `binomial_bandwidth(Z0, ZL, N, gm)`: the fractional band (as a fraction) over which an N-section binomial transformer keeps |Γ| below gm, using $A = 2^{-N}(Z_L - Z_0)/(Z_L + Z_0)$.

```python starter
def binomial_bandwidth(Z0, ZL, N, gm):
    return 0.0
```

```python solution
import math

def binomial_bandwidth(Z0, ZL, N, gm):
    A = abs((ZL - Z0) / (ZL + Z0)) / 2 ** N
    return 2 - 4 / math.pi * math.acos(0.5 * (gm / A) ** (1 / N))
```

```python tests
assert abs(binomial_bandwidth(50, 100, 2, 0.05) - 0.50637) < 1e-4, f"Two sections, 50 to 100 Ω, 0.05: 50.6%, got {binomial_bandwidth(50, 100, 2, 0.05)}."
assert abs(binomial_bandwidth(50, 100, 3, 0.1) - 0.93385) < 1e-4, "Three sections at 0.1: 93.4%."
assert abs(binomial_bandwidth(50, 200, 4, 0.05) - 0.72220) < 1e-4, "Four sections, 50 to 200 Ω, 0.05: 72.2%."
```

::: right
Right. More sections, or a looser target, widen the band.
:::
:::

::: explain
## Why does splitting an impedance step into several quarter-wave sections widen the band?

::: model
At the design frequency each section is a quarter wave long, so the reflections from successive steps arrive back with half-wave path differences and cancel. Off the design frequency the cancellation is imperfect, and how fast it degrades depends on how big the individual reflections are and how they're arranged. With several small steps, each reflection is small, and their binomial or Chebyshev weights make the leftover sum grow slowly away from the center: the binomial design's error goes as a high power of $\cos\theta$, staying near zero over a wide region. A single big step has one large reflection that can be cancelled only near one frequency. More sections means more small reflections that can be arranged to cancel over more frequencies.
:::
:::

::: practice
::: check
given: Z0 = 50; ZL = 10 | 12.5 | 25 | 75 | 100 | 200 | 300
answer: sqrt(Z0*ZL)
unit: Ω
tolerance: 0.5%

## Quarter-wave section from 50 Ω to {ZL} Ω?

::: misses
- [any] $\sqrt{Z_0Z_L}$.
:::
:::

::: check
given: ZL = 150 | 300; N = 2 | 3
answer: abs((ZL - 50)/(ZL + 50))*2^(-N)
tolerance: 0.5%

## Binomial coefficient A for N = {N} sections, 50 to {ZL} Ω?

::: misses
- [any] $2^{-N}(Z_L - Z_0)/(Z_L + Z_0)$.
:::
:::

::: check
given: R = 50; C = 1 | 4; B = 1 | 2
answer: exp(-pi/(R*C*1e-12*2*pi*B*1e9))
tolerance: 0.5%

## Bode–Fano: best constant |Γ| for 50 Ω ∥ {C} pF over {B} GHz?

::: misses
- [any] $e^{-\pi/(RC\Delta\omega)}$.
:::
:::
:::