C1016 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C10 · Lesson 16 · Impedance matching with lines and stubs

Quarter-wave transformers and single-stub tuners

An antenna that presents 25 + j40 Ω to a 50 Ω radio reflects nearly a third of the transmitter's power back at it. A matching network fixes that, and at microwave frequencies the network is usually made of line itself: a quarter-wave section of the right impedance, or a short stub placed at just the right distance from the load. On the Smith chart, matching is a journey to the center: first along a circle of constant |Γ| (moving along the line), then along a circle of constant conductance (adding a stub), until the load looks like exactly 50 Ω.

  • A load ZL sits on a 50 Ω line. Moving d wavelengths toward the source takes it to Z1; a shorted stub of length ls connected across the line there gives Z2, what the source finally sees.
  • First drag d until Z1 lands on the circle r = 1 when inverted (its admittance has real part 1). Then drag ls: the stub only adds susceptance, so Z2 slides along a circle of constant conductance.
  • Find the pair that puts Z2 at the center: the readout shows the remaining |Γ|. For the starting 100 Ω load, d = 0.152 and ls = 0.152 work.

Predict

A quarter-wave transformer matches 100 Ω to 50 Ω at 1 GHz. What does the source see at 2 GHz?

Name it

Quarter-wave transformer

To match a real load RL to Z0: a λ/4 section of impedance Z1=Z0RL. For complex loads, first move along the line to where the impedance is real (a voltage maximum or minimum), then add the transformer there. Several sections in a row, with impedances stepping gradually, widen the bandwidth.

Single-stub shunt matching

  1. Move a distance d from the load to where the normalized admittance is y=1+jb (the chart's g = 1 circle).
  2. Connect a stub in parallel there with susceptance −jb, leaving y = 1: matched.

For a real load RL>Z0, one solution is

dλ=12πtan−1⁡RLZ0,b=RL−Z0RLZ0

A shorted stub's normalized admittance is −jcot⁡βls, so canceling b needs

lsλ=12πtan−1⁡1b

(for b > 0; add a half wavelength's worth of angle, π, inside for b < 0). Open stubs work too and are often easier on a board; shorted ones avoid radiation from the open end.

Lumped L-networks

At lower frequencies the same jobs are done by a series and a shunt reactance (C3's L-network): with Q=Rhigh/Rlow−1, the series reactance is QRlow and the shunt reactance Rhigh/Q.

Worked example

Match a 100 Ω load to a 50 Ω line with a single shorted stub.

Show the solution
  1. Stub position. dλ=tan−1⁡22π=0.152
  2. Admittance there. The susceptance is b=505000=0.707 so y=1+j0.707.
  3. Stub length. The stub must add −j0.707: lsλ=tan−1⁡(1/0.707)2π=0.152
  4. A coincidence. Both happen to be 0.152 λ for this load.

Answer put a shorted stub 0.152λ long at 0.152λ from the load.

Worked example

Design a quarter-wave transformer from 25 Ω to 50 Ω at 2.4 GHz on FR-4 (εeff = 3.3).

Show the solution
  1. Section impedance. Z1=25×50Ω=35.4Ω
  2. Wavelength on the board. λ=299.82.43.3mm=68.8mm
  3. Quarter of it. 68.8mm4=17.2mm
  4. The trace. A wider trace than the 50 Ω line gives the lower impedance.

Answer a 35.4 Ω section 17.2 mm long.

Worked example

Match a 10 Ω load to 50 Ω at 100 MHz with an L-network.

Show the solution
  1. Q of the network. Q=5010−1=2
  2. Reactances. The element in series with the 10 Ω load has X=Q×10=20Ω and the shunt element across the 50 Ω side, of opposite type, has X=50Q=25Ω
  3. Series inductor. L=202π×100MHz=31.8nH
  4. Shunt capacitor. C=12π×100MHz×25=63.7pF
  5. Bandwidth. The match holds over roughly f/Q, about 50 MHz.

Answer a 31.8 nH series inductor next to the load and a 63.7 pF shunt capacitor across the 50 Ω side.

Check

What impedance should a quarter-wave transformer have to match 100 Ω to 50 Ω?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A 150 Ω load on a 50 Ω line is matched with a single shorted shunt stub.

(a)

How far from the load (in wavelengths) is the stub placed, for the first solution?

(b)

What normalized susceptance b does the line show there?

(c)

How long must the shorted stub be, in wavelengths?

Check

A shorted stub must provide a normalized susceptance of −j0.7. How long is it, in wavelengths?

Check

A quarter-wave transformer matches 75 Ω to 50 Ω at its design frequency. What is |Γ| at twice that frequency, where the section is half a wavelength?

Check

A lumped L-network matches 200 Ω to 10 Ω.

(a)

What is its Q?

(b)

What series reactance does it need?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

How long is a quarter-wave transformer at 2.4 GHz on a board with εeff = 3.3?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

Check

On the Smith chart, what path does adding a shunt stub take?

Check

An L-network matches a 10 Ω load to 50 Ω at 900 MHz.

(a)

What is its Q?

(b)

What series inductance does it use next to the load?

Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.

Check

A quarter-wave transformer matches 25 Ω to 50 Ω at 2.4 GHz, on a line with εeff = 1.

(a)

What impedance must the section have?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

How long is it?

Explain why

Why does single-stub matching need two adjustments, a position and a stub length?

Practice

Keep practicing

11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.