C10 · Lesson 16 · Impedance matching with lines and stubs
Quarter-wave transformers and single-stub tuners
An antenna that presents 25 + j40 Ω to a 50 Ω radio reflects nearly a third of the transmitter's power back at it. A matching network fixes that, and at microwave frequencies the network is usually made of line itself: a quarter-wave section of the right impedance, or a short stub placed at just the right distance from the load. On the Smith chart, matching is a journey to the center: first along a circle of constant |Γ| (moving along the line), then along a circle of constant conductance (adding a stub), until the load looks like exactly 50 Ω.
- A load sits on a 50 Ω line. Moving d wavelengths toward the source takes it to ; a shorted stub of length connected across the line there gives , what the source finally sees.
- First drag d until lands on the circle r = 1 when inverted (its admittance has real part 1). Then drag : the stub only adds susceptance, so slides along a circle of constant conductance.
- Find the pair that puts at the center: the readout shows the remaining |Γ|. For the starting 100 Ω load, d = 0.152 and = 0.152 work.
Predict
A quarter-wave transformer matches 100 Ω to 50 Ω at 1 GHz. What does the source see at 2 GHz?
100 Ω. At 2 GHz the 70.7 Ω section is λ/2 long, and a half-wave line repeats its load. Every line-based match works exactly at one frequency and degrades away from it; the bandwidth is part of the design.
Name it
Quarter-wave transformer
To match a real load to : a λ/4 section of impedance . For complex loads, first move along the line to where the impedance is real (a voltage maximum or minimum), then add the transformer there. Several sections in a row, with impedances stepping gradually, widen the bandwidth.
Single-stub shunt matching
- Move a distance d from the load to where the normalized admittance is (the chart's g = 1 circle).
- Connect a stub in parallel there with susceptance −jb, leaving y = 1: matched.
For a real load , one solution is
A shorted stub's normalized admittance is , so canceling b needs
(for b > 0; add a half wavelength's worth of angle, π, inside for b < 0). Open stubs work too and are often easier on a board; shorted ones avoid radiation from the open end.
Lumped L-networks
At lower frequencies the same jobs are done by a series and a shunt reactance (C3's L-network): with , the series reactance is and the shunt reactance .
Worked example
Match a 100 Ω load to a 50 Ω line with a single shorted stub.
Show the solution
- Stub position.
- Admittance there. The susceptance is so .
- Stub length. The stub must add :
- A coincidence. Both happen to be 0.152 λ for this load.
Answer put a shorted stub 0.152λ long at 0.152λ from the load.
Worked example
Design a quarter-wave transformer from 25 Ω to 50 Ω at 2.4 GHz on FR-4 ( = 3.3).
Show the solution
- Section impedance.
- Wavelength on the board.
- Quarter of it.
- The trace. A wider trace than the 50 Ω line gives the lower impedance.
Answer a 35.4 Ω section 17.2 mm long.
Worked example
Match a 10 Ω load to 50 Ω at 100 MHz with an L-network.
Show the solution
- Q of the network.
- Reactances. The element in series with the 10 Ω load has and the shunt element across the 50 Ω side, of opposite type, has
- Series inductor.
- Shunt capacitor.
- Bandwidth. The match holds over roughly f/Q, about 50 MHz.
Answer a 31.8 nH series inductor next to the load and a 63.7 pF shunt capacitor across the 50 Ω side.
Check
What impedance should a quarter-wave transformer have to match 100 Ω to 50 Ω?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A 150 Ω load on a 50 Ω line is matched with a single shorted shunt stub.
(a)
How far from the load (in wavelengths) is the stub placed, for the first solution?
(b)
What normalized susceptance b does the line show there?
(c)
How long must the shorted stub be, in wavelengths?
Check
A shorted stub must provide a normalized susceptance of −j0.7. How long is it, in wavelengths?
Check
A quarter-wave transformer matches 75 Ω to 50 Ω at its design frequency. What is |Γ| at twice that frequency, where the section is half a wavelength?
Check
A lumped L-network matches 200 Ω to 10 Ω.
(a)
What is its Q?
(b)
What series reactance does it need?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
How long is a quarter-wave transformer at 2.4 GHz on a board with = 3.3?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
On the Smith chart, what path does adding a shunt stub take?
Check
An L-network matches a 10 Ω load to 50 Ω at 900 MHz.
(a)
What is its Q?
(b)
What series inductance does it use next to the load?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Check
A quarter-wave transformer matches 25 Ω to 50 Ω at 2.4 GHz, on a line with = 1.
(a)
What impedance must the section have?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
How long is it?
Explain why
Why does single-stub matching need two adjustments, a position and a stub length?
A match requires the admittance at one point to equal exactly: both its real and imaginary parts must be right, two conditions. A stub can only add imaginary admittance, susceptance, so it can fix the imaginary part but not the real part. Moving along the line changes both parts of the admittance as the point turns around the chart, and there are particular positions where the real part is exactly . Choosing such a position satisfies the first condition, and choosing the stub length cancels whatever susceptance is left, the second.
Practice
Keep practicing
11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.