title: Line parameters from the fields
heading: Where L′ and C′ come from
eyebrow: C10 · Lesson 4 · Line parameters from the fields
xp: 40
---

::: hook
The inductance and capacitance per meter aren't properties someone measures and writes on a data sheet by magic; they follow from the electric and magnetic fields between the conductors, the same fields Physics II computed with Gauss's and Ampère's laws. For simple shapes, a coax or a pair of plates, the fields can be found exactly and L′, C′ and $Z_0$ written in closed form. For a real circuit-board trace they come from a numerical field solver, the kind of code built in A9. Either way, the field picture explains why a fatter conductor lowers the impedance and why the dielectric sets the speed.
:::

::: play
- A coax cross-section: the shading is the electric potential between the inner conductor (radius a) and the shield (radius b), and the arrows are the electric field, pointing outward and strongest at the inner conductor.
- Change a and b. The readouts give C′, L′ and $Z_0$ for an air dielectric. Moving the conductors closer (b/a toward 1) raises C′ and lowers L′.
- The field at the inner conductor's surface is highest when a is small, which is why high-voltage coax can't use a very thin center wire.
:::
:::

```sim plot
view: flow
x: x = -1..1
y: y = -1..1
slider: a = 0.05..0.5 = 0.2 step 0.01
slider: b = 0.55..0.95 = 0.8 step 0.01
shade: ln(sqrt(x^2 + y^2 + 0.000001)/b)/ln(a/b)*step(sqrt(x^2 + y^2) - a)*step(b - sqrt(x^2 + y^2)) + step(a - sqrt(x^2 + y^2))
dx: x/(x^2 + y^2 + 0.000001)*step(sqrt(x^2 + y^2) - a)*step(b - sqrt(x^2 + y^2))
dy: y/(x^2 + y^2 + 0.000001)*step(sqrt(x^2 + y^2) - a)*step(b - sqrt(x^2 + y^2))
path: a*cos(u), a*sin(u) | over: u = 0..6.2832
path: b*cos(u), b*sin(u) | over: u = 0..6.2832
grid: 18
readout: C′ (air), pF/m = 55.633/ln(b/a) | digits: 4
readout: L′, nH/m = 200*ln(b/a) | digits: 4
readout: Z₀ (air), Ω = 59.958*ln(b/a) | digits: 4
```

::: predict
## An air coax has b/a = e = 2.718. What is its capacitance per meter?

- [ ] 8.85 pF/m
- [x] 55.6 pF/m
- [ ] 100 pF/m
- [ ] 1 nF/m

::: reveal
$C' = 2\pi\varepsilon_0/\ln(b/a) = 2\pi \times 8.854 \times 10^{-12}/1 = 55.6$ pF/m. With $\ln(b/a) = 1$ the geometry drops out, leaving $2\pi\varepsilon_0$.
:::
:::

::: nameit
## Coax

With charge q per meter on the inner conductor, Gauss's law gives $E = q/(2\pi\varepsilon r)$, so the voltage between conductors is $(q/2\pi\varepsilon)\ln(b/a)$ and

$$C' = \frac{2\pi\varepsilon}{\ln(b/a)}, \qquad L' = \frac{\mu}{2\pi}\ln\frac{b}{a}$$

(L′ from Ampère's law, $B = \mu I/2\pi r$, and the flux between the conductors). Then $L'C' = \mu\varepsilon$ and $Z_0 = \sqrt{L'/C'} = \frac{\eta}{2\pi}\ln\frac ba$, with $\eta = \sqrt{\mu/\varepsilon}$ = 377 Ω/$\sqrt{\varepsilon_r}$: the 60 ln(b/a) of the last lesson. In numbers: $C' = 55.6\,\varepsilon_r/\ln(b/a)$ pF/m and $L' = 200\ln(b/a)$ nH/m.

## Parallel plates

Strips of width w a distance d apart (w ≫ d, fringing ignored): $C' = \varepsilon w/d$, $L' = \mu d/w$, and $Z_0 = \eta\,d/w$.

## Two wires

Diameter d, spacing D: $C' = \pi\varepsilon/\cosh^{-1}(D/d)$ and $L' = (\mu/\pi)\cosh^{-1}(D/d)$.

## Fields at the conductors

In a coax at voltage V, the field at the inner conductor is $E = V/(a\ln(b/a))$, its largest value anywhere. Breakdown, and the highest power a cable can take, are set there.

## The inside of the conductors

These are the external inductances. Current inside the conductors adds a little internal inductance at low frequencies, but at high frequencies the skin effect pushes the current to the surfaces and the internal part vanishes.
:::

::: example
## An air coax has a = 1 mm and b = 2.3 mm. Find C′, L′ and $Z_0$.

::: solution
1. **The log of the radius ratio.**
   $$\ln 2.3 = 0.833$$
2. **Capacitance per meter.** In air, $C' = 55.6/\ln(b/a)$ pF/m:
   $$\begin{aligned} C' &= \frac{55.6}{0.833}\ \text{pF/m} \\ &= 66.8\ \text{pF/m} \end{aligned}$$
3. **Inductance per meter.**
   $$\begin{aligned} L' &= 200 \times 0.833\ \text{nH/m} \\ &= 166.6\ \text{nH/m} \end{aligned}$$
4. **Characteristic impedance.**
   $$\begin{aligned} Z_0 &= \sqrt{\frac{166.6 \times 10^{-9}}{66.8 \times 10^{-12}}}\ \Omega \\ &= 49.9\ \Omega \end{aligned}$$
   That's the classic air-line ratio for 50 Ω.

**Answer:** C′ = 66.8 pF/m, L′ = 166.6 nH/m and $Z_0$ = 49.9 Ω.
:::
:::

::: example
## A strip 5 mm wide runs 1 mm above a ground plane in a material with $\varepsilon_r$ = 4 (treat it as parallel plates). Estimate $Z_0$.

::: solution
1. **Parallel-plate impedance.** The wave impedance of the material is $377/\sqrt4$ Ω, scaled by the spacing over the width:
   $$\begin{aligned} Z_0 &= \frac{\eta d}{w} \\ &= \frac{377}{\sqrt4} \times \frac15\ \Omega \\ &= 37.7\ \Omega \end{aligned}$$
2. **Fringing.** Fringing fields add capacitance, so the real value is a little lower; field solvers or microstrip design formulas account for it.

**Answer:** $Z_0$ is about 37.7 Ω, a little less in practice.
:::
:::

::: example
## A two-wire line in air has wires of radius 0.5 mm, 10 mm apart center to center. Find L′, C′ and $Z_0$.

::: solution
1. **The geometry term.** With $D/2a = 10$,
   $$\operatorname{acosh}(10) = 2.993$$
2. **Inductance per meter.**
   $$\begin{aligned} L' &= \frac{\mu_0}{\pi}\operatorname{acosh}\frac{D}{2a} \\ &= 1.20\ \mu\text{H/m} \end{aligned}$$
3. **Capacitance per meter.**
   $$\begin{aligned} C' &= \frac{\pi\varepsilon_0}{\operatorname{acosh}(D/2a)} \\ &= 9.29\ \text{pF/m} \end{aligned}$$
4. **Characteristic impedance.**
   $$\begin{aligned} Z_0 &= \sqrt{\frac{L'}{C'}} \\ &= 120\operatorname{acosh}\frac{D}{2a} \\ &= 359\ \Omega \end{aligned}$$
   That's the classic 300 Ω ribbon cable's neighborhood: widely spaced thin wires give high impedance.

**Answer:** L′ = 1.20 µH/m, C′ = 9.29 pF/m and $Z_0$ = 359 Ω.
:::
:::

::: check
given: r = 1.5 | 2.3 | 4; er = 2.25 | 3.5 | 4.4
answer: 55.633*er/ln(r)
unit: pF/m
tolerance: 0.5%

## What is C′, in pF per meter, for a coax with b/a = {r} filled with $\varepsilon_r$ = {er}?

::: right
Right. $2\pi\varepsilon_0\varepsilon_r/\ln(b/a)$ = {answer} pF/m.
:::

::: misses
- [55.633/ln(r)] Include the dielectric's $\varepsilon_r$.
- [any] Not yet. $C' = 2\pi\varepsilon/\ln(b/a)$.
:::
:::

::: check
given: r = 2 | 3.5 | 7
answer: 200*ln(r)
unit: nH/m
tolerance: 0.5%

## What is L′, in nH per meter, for a coax with b/a = {r}?

::: right
Right. $(\mu_0/2\pi)\ln(b/a)$ = {answer} nH/m.
:::

::: misses
- [200*log(r)] Use the natural logarithm.
- [any] Not yet. $\mu_0/2\pi$ = 200 nH/m, times ln(b/a).
:::
:::

::: check
kind: parts
given: w = 2 | 5 | 10; d = 0.5 | 1; er = 2.25 | 4.4

## A parallel-plate line has strips {w} mm wide, {d} mm apart, with $\varepsilon_r$ = {er} (ignore fringing).

::: part
answer: 376.73/sqrt(er)*d/w
unit: Ω
tolerance: 0.5%

### What is $Z_0$?

::: misses
- [376.73*d/w] The wave impedance in the dielectric is $377/\sqrt{\varepsilon_r}$.
- [any] Not yet. $\eta d/w$.
:::
:::

::: part
answer: 8.8542*er*w/d
unit: pF/m
tolerance: 0.5%

### What is C′, in pF per meter?

::: misses
- [any] $\varepsilon w/d$.
:::
:::
:::

::: check
given: D = 2 | 5 | 10; d = 1
answer: pi*8.8542/ln(D/d + sqrt((D/d)^2 - 1))
unit: pF/m
tolerance: 0.5%

## Two wires of diameter {d} mm are {D} mm apart in air. What is C′, in pF per meter?

::: right
Right. $\pi\varepsilon_0/\cosh^{-1}(D/d)$ = {answer} pF/m.
:::

::: misses
- [2*pi*8.8542/ln(D/d + sqrt((D/d)^2 - 1))] That's the coax constant; two wires give $\pi\varepsilon$.
- [any] Not yet. $\pi\varepsilon_0/\cosh^{-1}(D/d)$.
:::
:::

::: check
given: V = 100 | 1000 | 5000; a = 0.5 | 1; r = 3 | 4
answer: V/(a*1e-3*ln(r))/1e6
unit: MV/m
tolerance: 0.5%

## A coax with inner radius {a} mm and b/a = {r} is at {V} V. How strong is the field at the inner conductor's surface, in MV/m?

::: right
Right. $V/(a\ln(b/a))$ = {answer} MV/m. Air breaks down near 3 MV/m.
:::

::: misses
- [V/(a*1e-3*r*1e-3)/1e6] Use $a\ln(b/a)$, from integrating E = q/(2πεr).
- [any] Not yet. $E(a) = V/(a\ln(b/a))$.
:::
:::

::: check
given: er = 1 | 2.25 | 4.4
answer: er/299792458^2*1e18
tolerance: 0.5%

## For any TEM line in a dielectric with $\varepsilon_r$ = {er}, what is L′C′, in units of $10^{-18}$ s²/m²?

::: right
Right. $\mu_0\varepsilon_0\varepsilon_r = \varepsilon_r/c^2$ = {answer} × 10⁻¹⁸.
:::

::: misses
- [any] Not yet. $L'C' = \mu\varepsilon$.
:::
:::

::: check
kind: choice

## At high frequency the skin effect confines a coax's currents to thin layers at the conductors' surfaces. What happens to L′?

- [ ] It rises sharply
- [x] It falls slightly, to the external value $(\mu/2\pi)\ln(b/a)$, as the internal inductance disappears
- [ ] It drops to zero
- [ ] It doesn't change at all

::: misses
- [1] Less flux links current inside the conductor, so inductance falls.
- [3] The flux between the conductors is still there.
- [4] The small internal part goes away.
:::
:::

::: check
kind: parts
given: r = 2 | 3.6 | 5; e = 1 | 2.25

## A coax has b/a = {r} and $\varepsilon_r$ = {e}.

::: part
answer: 2*pi*8.854*e/ln(r)
unit: pF/m
tolerance: 0.5%

### What is C′?

::: misses
- [any] $2\pi\varepsilon/\ln(b/a)$.
:::
:::

::: part
answer: 200*ln(r)
unit: nH/m
tolerance: 0.5%

### What is L′?

::: misses
- [any] $\frac{\mu_0}{2\pi}\ln(b/a)$.
:::
:::
:::

::: check
kind: parts
given: d = 0.2 | 1; w = 1 | 3 | 5; e = 1 | 4

## A strip {w} mm wide sits {d} mm over a ground plane in $\varepsilon_r$ = {e}; treat it as parallel plates.

::: part
answer: 376.7/sqrt(e)*d/w
unit: Ω
tolerance: 0.5%

### Estimate $Z_0$.

::: misses
- [any] $\eta\,d/w$ with $\eta = 377/\sqrt{\varepsilon_r}$.
:::
:::

::: part
answer: 8.854*e*w/d
unit: pF/m
tolerance: 0.5%

### Estimate C′.

::: misses
- [any] $\varepsilon w/d$.
:::
:::
:::

::: explain
## Why does making a coax's center conductor fatter lower its characteristic impedance?

::: model
A fatter center conductor brings the two conductors closer together. For a given voltage between them, the electric field is concentrated into a thinner gap, so more charge is needed per volt: C′ goes up. For a given current, the magnetic field circling the center has less room between the conductors, so less flux links each ampere: L′ goes down. $Z_0 = \sqrt{L'/C'}$ falls on both counts, and the formula $Z_0 = (\eta/2\pi)\ln(b/a)$ shows it smoothly approaching zero as b/a approaches 1.
:::
:::

::: practice

::: check
given: r = 2.5 | 5; er = 1 | 2.25
answer: 55.633*er/ln(r)
unit: pF/m
tolerance: 0.5%

## C′ of a coax with b/a = {r}, $\varepsilon_r$ = {er}, in pF/m?

::: misses
- [any] $55.6\varepsilon_r/\ln(b/a)$.
:::
:::

::: check
given: r = 1.8 | 2.3 | 3 | 3.5 | 4.6 | 6.5
answer: 200*ln(r)
unit: nH/m
tolerance: 0.5%

## L′ of a coax with b/a = {r}, in nH/m?

::: misses
- [any] 200 ln(b/a).
:::
:::

::: check
given: w = 4 | 8; d = 1 | 2
answer: 376.73*d/w
unit: Ω
tolerance: 0.5%

## $Z_0$ of an air parallel-plate line, w = {w} mm, d = {d} mm?

::: misses
- [any] 377 d/w.
:::
:::
:::