title: Waves in lossy materials
heading: From good dielectrics to good conductors
eyebrow: C10 · Lesson 30 · Waves in lossy materials
xp: 40
---

::: hook
Submarines receive orders at frequencies of a few kilohertz, because seawater swallows anything faster within meters. A microwave oven heats food from the outside in, because water absorbs 2.45 GHz within a few centimeters. Radar sees through dry sand and not wet soil. Each of these comes down to one comparison: is the material's conduction current bigger or smaller than its displacement current at that frequency? The ratio, the **loss tangent**, decides whether a material acts as a lossy dielectric or as a conductor, and how far a wave gets into it.
:::

::: play
- The curve is how fast a wave's amplitude decays in a material of conductivity σ and permittivity $\varepsilon_r$, in dB per meter, across frequency.
- At low frequency, conduction dominates: the material acts as a conductor and the loss grows as $\sqrt f$. Above the transition frequency (the marker) it acts as a lossy dielectric and the loss levels off at a value set by σ.
- Start with seawater (σ = 4 S/m, $\varepsilon_r$ = 81). Then try fresh water (σ ≈ 0.01 S/m) or dry soil (0.001 S/m) and watch the transition move down.
:::
:::

```sim plot
view: graph
x: f = 1k..100G Hz log
y: A = 0.0001..10000 log
slider: s = 0.0001..10 = 4 log
slider: er = 1..81 = 81 step 1
plot: 8.686*2*pi*f*sqrt(4e-7*pi*er*8.8541878e-12/2)*sqrt(sqrt(1 + (s/(2*pi*f*er*8.8541878e-12))^2) - 1) | samples: 800 | label: dB/m
marker: x = s/(2*pi*er*8.8541878e-12) | label: σ = ωε
readout: transition frequency = s/(2*pi*er*8.8541878e-12) Hz | format: si
readout: loss at high frequency, dB/m = 8.686*s/2*376.73/sqrt(er) | digits: 3
```

::: predict
## Seawater has σ = 4 S/m. About how deep does a 10 kHz signal penetrate before falling to 1/e?

- [ ] 2.5 mm
- [ ] 25 cm
- [x] 2.5 m
- [ ] 250 m

::: reveal
2.5 m. At 10 kHz seawater is a good conductor, and its skin depth is $1/\sqrt{\pi f\mu_0\sigma} = 1/\sqrt{\pi \times 10^4 \times 4\pi \times 10^{-7} \times 4} = 2.5$ m. At 1 MHz it's only 25 cm, which is why submarine radio uses such low frequencies.
:::
:::

::: nameit
## The loss tangent

A material with conductivity σ carries conduction current σE alongside displacement current jωεE. Their ratio is the **loss tangent**:

$$\tan\delta = \frac{\sigma}{\omega\varepsilon}$$

(materials with molecular losses, like water at microwave frequencies, are described by an imaginary permittivity ε″ instead, with tan δ = ε″/ε′). The **transition frequency**, where tan δ = 1, is $f_t = \sigma/(2\pi\varepsilon)$.

## The attenuation

Exactly, for a nonmagnetic material,

$$\alpha = \omega\sqrt{\frac{\mu\varepsilon}{2}}\sqrt{\sqrt{1 + \tan^2\delta} - 1}$$

in nepers per meter, with two simple limits:

| Regime | Condition | α | |
|---|---|---|---|
| low-loss dielectric | $\tan\delta \ll 1$ | $\dfrac{\sigma\eta}{2}$ | independent of f |
| good conductor | $\tan\delta \gg 1$ | $\sqrt{\pi f\mu\sigma} = 1/\delta$ | grows as $\sqrt f$ |

with η the lossless wave impedance, $376.7/\sqrt{\varepsilon_r}$ Ω. In a good conductor β = α as well, so the wave dies within about one wavelength, and the conductor's wave impedance is tiny, $(1 + j)/(\sigma\delta)$, which is why metals reflect almost everything (lesson 31).

The field falls to 1/e in 1/α and the power in 1/(2α); in dB, the loss is 8.686α per meter.
:::

::: example
## Is seawater (σ = 4 S/m, $\varepsilon_r$ = 81) a conductor or a dielectric at 10 kHz, and what is its skin depth?

::: solution
1. **Loss tangent.**
   $$\begin{aligned} \tan\delta &= \frac{\sigma}{\omega\varepsilon} \\ &= \frac{4}{2\pi \times 10^4 \times 81\varepsilon_0} \\ &= 8.9 \times 10^4 \end{aligned}$$
   so seawater is an excellent conductor at 10 kHz.
2. **Skin depth.**
   $$\begin{aligned} \delta &= \frac{1}{\sqrt{\pi f\mu_0\sigma}} \\ &= 2.52\ \text{m} \end{aligned}$$
   matching the exact formula.

**Answer:** seawater is an excellent conductor at 10 kHz, with a skin depth of 2.52 m.
:::
:::

::: example
## Water at 2.45 GHz has $\varepsilon_r' \approx 78$ and $\varepsilon_r'' \approx 10$. How deep do microwaves penetrate?

::: solution
1. **Effective conductivity.**
   $$\omega\varepsilon_0\varepsilon'' = 1.36\ \text{S/m}$$
2. **Loss tangent.**
   $$\begin{aligned} \tan\delta &= \frac{10}{78} \\ &= 0.13 \end{aligned}$$
   so water is a lossy dielectric here.
3. **Penetration depth.** The exact formula gives α = 29 Np/m, so the field falls to 1/e in 3.4 cm and the power in 1.7 cm.
4. **What it means for cooking.** Food more than a few centimeters thick is heated from the outside in.

**Answer:** the field falls to 1/e in 3.4 cm, and the power in 1.7 cm.
:::
:::

::: example
## What is the skin depth in copper at 60 Hz, and what does it mean for power cables?

::: solution
1. **Skin depth.**
   $$\begin{aligned} \delta &= \sqrt{\frac{2}{\omega\mu\sigma}} \\ &= \sqrt{\frac{2}{377 \times \mu_0 \times 5.8 \times 10^7}}\ \text{m} \\ &= 8.5\ \text{mm} \end{aligned}$$
2. **What it means for cables.** Conductors much thicker than about 2δ carry little current in their centers, which is why large power conductors are stranded and why very large ones become hollow tubes.

**Answer:** the skin depth is 8.5 mm, so very thick power conductors are stranded or made as hollow tubes.
:::
:::

::: check
given: s = 0.001 | 0.05 | 4; f = 1 | 100 | 10000; er = 10 | 80
answer: s/(2*pi*f*1e6*er*8.8541878e-12)
tolerance: 0.5%

## What is the loss tangent of a material with σ = {s} S/m and $\varepsilon_r$ = {er} at {f} MHz?

::: right
Right. $\sigma/(\omega\varepsilon)$ = {answer}.
:::

::: misses
- [s/(f*1e6*er*8.8541878e-12)] Use ω = 2πf.
- [any] Not yet. $\sigma/(2\pi f\varepsilon_0\varepsilon_r)$.
:::
:::

::: check
given: s = 3.5e7 | 5.8e7 | 4 ; f = 0.01 | 1 | 100
answer: 1/sqrt(pi*f*1e6*4e-7*pi*s)
unit: m
tolerance: 0.5%

## What is the skin depth of a good conductor with σ = {s} S/m at {f} MHz?

::: right
Right. $1/\sqrt{\pi f\mu_0\sigma}$ = {answer} m.
:::

::: misses
- [any] Not yet. $\delta = 1/\sqrt{\pi f\mu_0\sigma}$.
:::
:::

::: check
given: s = 0.0001 | 0.001 | 0.01; er = 2.25 | 4 | 9
answer: 8.686*s/2*376.73/sqrt(er)
unit: dB
tolerance: 0.5%

## A low-loss dielectric has σ = {s} S/m and $\varepsilon_r$ = {er}. How many dB per meter does a wave lose in it?

::: right
Right. $8.686\,\sigma\eta/2$ = {answer} dB/m, the same at any frequency where it's low-loss.
:::

::: misses
- [s/2*376.73/sqrt(er)] That's in nepers per meter.
- [8.686*s/2*376.73] Use the material's η, $376.7/\sqrt{\varepsilon_r}$.
- [any] Not yet. $\alpha = \sigma\eta/2$.
:::
:::

::: check
given: f = 1 | 2.45 | 10; s = 0.1 | 1.4; er = 40 | 78
answer: 1/(2*pi*f*1e9*sqrt(4e-7*pi*er*8.8541878e-12/2)*sqrt(sqrt(1 + (s/(2*pi*f*1e9*er*8.8541878e-12))^2) - 1))*100
unit: cm
tolerance: 0.5%

## A tissue-like material (σ = {s} S/m, $\varepsilon_r$ = {er}) is exposed to {f} GHz. Using the exact formula, how deep does the field go before falling to 1/e?

::: right
Right. 1/α = {answer} cm.
:::

::: misses
- [any] Not yet. Compute α exactly and invert it.
:::
:::

::: check
given: s = 0.01 | 1 | 4; er = 10 | 81
answer: s/(2*pi*er*8.8541878e-12)/1e6
unit: MHz
tolerance: 0.5%

## Below what frequency does a material with σ = {s} S/m and $\varepsilon_r$ = {er} behave mainly as a conductor?

::: right
Right. Where σ = ωε: {answer} MHz.
:::

::: misses
- [any] Not yet. $f_t = \sigma/(2\pi\varepsilon)$.
:::
:::

::: check
given: a = 0.5 | 3 | 30; d = 0.1 | 1 | 5
answer: 8.686*a*d
unit: dB
tolerance: 0.5%

## A wave travels {d} m through a material with α = {a} Np/m. How many dB does it lose?

::: right
Right. 8.686αd = {answer} dB.
:::

::: misses
- [a*d] That's in nepers.
- [any] Not yet. $8.686\alpha d$.
:::
:::

::: check
kind: choice

## A material's loss tangent at 100 MHz is 0.01. How does a wave's attenuation in it change if the frequency doubles (still low-loss)?

- [ ] It doubles
- [ ] It grows by √2
- [x] It stays about the same, set by σ
- [ ] It halves

::: misses
- [1] In a conductor-like material it would grow; here it's a low-loss dielectric.
- [2] That's the good-conductor regime.
- [4] It doesn't fall either: σ and η don't change.
:::
:::

::: check
kind: parts
given: s = 0.01 | 4 | 5.8e7; f = 0.01 | 1 | 1000; e = 4 | 81

## A material has σ = {s} S/m and $\varepsilon_r$ = {e}, at {f} MHz.

::: part
answer: s/(2*pi*f*1e6*e*8.854e-12)
tolerance: 0.5%

### What is its loss tangent, $\sigma/\omega\varepsilon$?

::: misses
- [any] $\sigma/(\omega\varepsilon_0\varepsilon_r)$.
:::
:::

::: part
answer: 1 - step(1 - s/(2*pi*f*1e6*e*8.854e-12))
tolerance: 0

### Does it act as a good conductor (1) or a dielectric (0) here, using a loss tangent above 1 as the test?

::: misses
- [any] Compare the loss tangent with 1.
:::
:::
:::

::: check
kind: parts
given: d = 0.5 | 8.5 | 66; A = 40 | 60 | 100

## A field decays with skin depth {d} mm.

::: part
answer: 20*log(exp(1))
unit: dB
tolerance: 0.5%

### How many dB does it lose per skin depth?

::: misses
- [any] $20\log_{10}e$.
:::
:::

::: part
answer: A/(20*log(exp(1)))*d
unit: mm
tolerance: 0.5%

### How thick must the material be to attenuate it by {A} dB?

::: misses
- [any] {A} dB at 8.69 dB per skin depth.
:::
:::
:::

::: explain
## Why does the same material act as a conductor at low frequencies and as a dielectric at high ones?

::: model
An oscillating field drives two currents through a material: conduction current, σE, which doesn't depend on frequency, and displacement current, ωεE, which grows with frequency. At low frequencies the conduction current is far larger, so the material behaves like a conductor: the wave induces currents that dissipate it within a skin depth. At high frequencies the displacement current dominates, the material behaves like a dielectric with a little loss, and the wave travels many wavelengths. The crossover, where σ = ωε, is the transition frequency, and real materials like soil, water and tissue sit on one side or the other depending on the band.
:::
:::

::: practice

::: check
given: s = 0.1 | 2; f = 10 | 1000; er = 30
answer: s/(2*pi*f*1e6*er*8.8541878e-12)
tolerance: 0.5%

## Loss tangent: σ = {s}, $\varepsilon_r$ = {er}, {f} MHz?

::: misses
- [any] $\sigma/\omega\varepsilon$.
:::
:::

::: check
given: f = 0.001 | 0.01 | 0.03 | 0.1 | 0.3 | 1; s = 4
answer: 1/sqrt(pi*f*1e6*4e-7*pi*s)
unit: m
tolerance: 0.5%

## Skin depth in seawater at {f} MHz?

::: misses
- [any] $1/\sqrt{\pi f\mu_0\sigma}$.
:::
:::

::: check
given: s = 0.001 | 0.02; er = 4 | 16
answer: 8.686*s/2*376.73/sqrt(er)
unit: dB
tolerance: 0.5%

## Low-loss attenuation for σ = {s}, $\varepsilon_r$ = {er}, in dB/m?

::: misses
- [any] $8.686\sigma\eta/2$.
:::
:::
:::