C1036 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C10 · Lesson 36 · Rectangular waveguides

Guiding waves through a hollow metal pipe

At tens of gigahertz, coax loses too much: its thin center conductor's resistance and its dielectric both grow with frequency. Radar transmitters, satellite ground stations and particle accelerators use waveguides instead: hollow metal pipes, usually rectangular, with nothing inside but air. A single pipe has no second conductor, so it can't carry a TEM wave or DC. Instead it carries waves that bounce between its walls in fixed patterns called modes, each of which only propagates above its own cutoff frequency. Below cutoff, the field dies away within a few millimeters.

  • The curves are the phase constant β of a rectangular guide's first three modes (TE₁₀, TE₂₀, TE₀₁) against frequency, for a guide with a broad wall a and narrow wall b. The dashed line is a wave in free space.
  • Each mode starts at its cutoff, where β = 0, and approaches the free-space line far above it.
  • Start at the standard X-band guide, WR-90 (a = 22.86 mm, b = 10.16 mm): only TE₁₀ propagates from 6.56 to 13.1 GHz. That single-mode band is where the guide is used.

Predict

A WR-90 waveguide's broad wall is 22.86 mm wide. Below what frequency can no wave travel along it?

Name it

Modes

A rectangular guide (inside dimensions a > b) carries transverse-electric modes TEmn (no E along the guide) and transverse-magnetic modes TMmn (no H along it), where m and n count half-wave field variations across a and b. With no center conductor there's no TEM mode. Each mode has a cutoff frequency

fc,mn=c2εr(ma)2+(nb)2

and propagates only above it, with

β=2πfv1−(fc/f)2

TM modes need both m and n at least 1, so the lowest mode is TE10, with fc=c/2a and an electric field across the narrow dimension varying as sin⁡(πx/a), largest in the middle of the broad wall.

The single-mode band

From fc,10 up to the next cutoff, which is TE20 at c/a when a≥2b (or TE01 at c/2b otherwise), only TE10 propagates. Standard guides use about 1.25 to 1.9 times fc,10, away from both edges.

Below cutoff

Below fc a mode is evanescent: it decays as e−αz with

α=2πfcc1−(f/fc)2

hundreds of dB per meter. That makes a short pipe below cutoff an excellent shield, as in the mesh window of a microwave oven.

Filling the guide

A dielectric of permittivity εr lowers every cutoff by εr, so a filled guide can be smaller.

Worked example

Find WR-90's single-mode band.

Show the solution
  1. Lowest cutoff. fc,10=c2×22.86mm=6.557GHz
  2. The next modes. TE20:ca=13.11GHz TE01:c2b=14.75GHz so TE20 sets the top.
  3. In practice. WR-90 is specified for 8.2 to 12.4 GHz, the X band.

Answer WR-90 is single-mode from 6.56 to 13.1 GHz.

Worked example

How fast does a 5 GHz field decay in WR-90?

Show the solution
  1. Below cutoff. 5 GHz is below the 6.557 GHz cutoff, so the field decays instead of propagating.
  2. Attenuation. α=2π×6.557×109c×1−(56.557)2=88.9Np/m
  3. In decibels. 88.9×8.686=772dB/m which is 7.7 dB per centimeter of pipe.

Answer it decays at 772 dB/m, 7.7 dB per centimeter.

Worked example

WR-284 has a = 72.14 mm and b = 34.04 mm. Where are its TE₁₀ and TE₂₀ cutoffs, and is TE₀₁ a concern?

Show the solution
  1. TE₁₀ cutoff. c2a=2.078GHz
  2. TE₂₀ cutoff. ca=4.156GHz
  3. TE₀₁ cutoff. c2b=4.40GHz above TE₂₀, so it isn't a concern.
  4. Single-mode band. That's 2.08 to 4.16 GHz, and in practice it's used from about 2.6 to 3.95 GHz, for S-band radar.

Answer TE₁₀ cuts off at 2.078 GHz and TE₂₀ at 4.156 GHz; TE₀₁, at 4.40 GHz, is above TE₂₀ and not a concern.

Check

What is the TE₁₀ cutoff of a rectangular guide with a = 22.86 mm, filled with εr = 1?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

Check

An air-filled guide is 20 mm by 8 mm. What is the cutoff of the mode with m = 2, n = 1?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

Check

An air-filled guide is 40 mm by 10.16 mm.

(a)

Where does its single-mode band start?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

(b)

Where does it end (the lower of the TE₂₀ and TE₀₁ cutoffs)?

Check

A mode with cutoff 6.557 GHz is driven at 0.5 of its cutoff. How many dB per meter does it decay?

Check

What is β for TE₁₀ in WR-90 (fc = 6.557 GHz) at 10 GHz?

Write units the way you normally would: 1.5 rad/m and 1500 mrad/m are the same answer.

Check

A microwave oven's door has round-ish holes about 3 mm across, treated as square guides of side 3 mm and depth 3 mm. About how many dB does 2.45 GHz lose crossing one?

Check

Why can't a hollow rectangular waveguide carry DC or a TEM wave?

Check

A rectangular waveguide is 47.55 mm wide.

(a)

Where is the TE₁₀ cutoff?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

(b)

And TE₂₀?

Check

A waveguide is 22.86 mm wide and 0.3 times as tall.

(a)

Where is the TE₀₁ cutoff?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

(b)

Where does the single-mode band end? (TE₂₀ or TE₀₁, whichever is lower; here b < a/2.)

Explain why

Why does a waveguide mode have a cutoff frequency?

Practice

Keep practicing

11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.