C10 · Lesson 8 · Transients on lines and time-domain reflectometry
Bounce diagrams, ringing, and finding faults by their echoes
A fast logic gate drives a long trace into a chip's input. The gate's output resistance is low, the input's impedance is high, and neither matches the trace. The step reflects off the input, then off the gate, then off the input again, and the receiver sees the voltage overshoot, undershoot and ring before it settles, which can clock a flip-flop twice or damage an input. Tracking each reflection in turn, with a bounce diagram, predicts exactly what the receiver sees. Run backward, the same idea finds a fault: send a step down a cable and time the echo, and a time-domain reflectometer tells you where the cable is damaged and how.
- A 1 V step from a source with resistance drives a 50 Ω line with a 5 ns one-way delay into a load . The curve is the voltage at the load.
- Start with = 10 Ω and a high-impedance load: the first arrival overshoots to 1.67 V, then the voltage rings around its final value as reflections bounce back and forth.
- Set = 50 Ω (series termination): the load jumps straight to 1 V and stays. Or set = 50 Ω (parallel termination): no reflection at all.
Predict
A 1 V step comes from a 10 Ω source into a 50 Ω line whose far end is open. What voltage first appears at the open end?
1.67 V. The source launches V, and the open end doubles it (Γ = +1). Then the reflection reaches the source, where sends back −0.556 V, pulling the load down to 0.56 V on its next arrival: the start of the ringing.
Name it
The bounce sequence
A source with resistance drives a line (, one-way delay T) into a load . With and :
- At t = 0 the source launches .
- At t = T it reaches the load, which jumps to , and heads back.
- At t = 2T that reaches the source, and heads out again.
- At t = 3T the load gains another , and so on.
So the load voltage after the kth arrival is , a geometric series that converges to the DC answer, . A bounce (lattice) diagram draws each wave as a diagonal line in distance and time.
If the load overshoots and rings; if it's positive the load climbs in a staircase.
Terminations
- Series: add resistance at the driver so . The load sees a half-height wave doubled by its own reflection to the full step, which is absorbed when it returns to the source. Cheap and low-power, but the middle of the line sees a half-step for a while.
- Parallel: a resistor at the load absorbs the wave at once. Clean everywhere, but it draws DC current.
Time-domain reflectometry
Send a fast step from a matched source and watch the sending end. A discontinuity at distance d returns an echo after , so
and the size of the step it adds, , gives the impedance there: up for an open or a higher impedance, down for a short or a lower one.
Worked example
A matched 50 Ω TDR sends a 1 V step (0.5 V on the line) into a cable with v = 2 × 10⁸ m/s. The display jumps from 0.5 V to 1 V after 60 ns. What and where is the fault?
Show the solution
- What the echo says. The echo raised the sending end by +0.5 V, equal to the incident step, so an open circuit.
- Where it is. The 60 ns covers the trip out and back:
Answer the cable is open 6 m down.
Worked example
Find the first three load voltages for the predict's circuit (10 Ω source, open load, 1 V).
Show the solution
- The launched step and the reflection coefficients.
- First arrival. The open load doubles the step:
- Second arrival.
- Third arrival.
- Where it settles. It rings around 1 V, the DC value with no load current.
Answer the load reads 1.667 V, then 0.556 V, then 1.296 V, ringing around 1 V.
Worked example
A 1 V step from a 25 Ω source drives a 50 Ω line ending in 100 Ω. Find the load voltage after the first arrival, after the next one, and finally.
Show the solution
- Launched step.
- Reflection coefficients.
- First arrival.
- Second arrival. The 0.222 V reflection returns to the source, which sends back −1/3 of it, −0.074 V. Arriving at the load, that changes the voltage by :
- Final value. It settles at the DC divider value, overshooting and ringing on the way:
Answer the load reads 0.889 V after the first arrival, 0.790 V after the next, and settles at 0.8 V.
Check
A 1 V step comes from a 10 Ω source into a 50 Ω line ending in 1000000 Ω. What voltage first appears at the load?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 1 V step from a 20 Ω source drives a 50 Ω line into 200 Ω. What is the load voltage after the second arrival, at t = 3T?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 2 V source with 10 Ω drives a line into 1000 Ω. What does the load voltage finally settle to?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A TDR sees an echo 80 ns after its step. Signals travel at 2 × 10⁸ m/s. How far away is the fault?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
A matched TDR launches 0.5 V into a 50 Ω cable. An echo changes the display by −0.2 V. What impedance caused it?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A driver with 8 Ω output resistance drives a 65 Ω trace. What series resistor terminates it?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A series-terminated line () drives a high-impedance receiver. What does a probe halfway along the line see?
Check
A TDR sees a reflection 150 ns after the step leaves, on a cable with v = 2 × 10⁸ m/s.
(a)
How far away is the fault?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
(b)
How long does a signal take per meter of this cable?
Check
A 1 V step from a 25 Ω source drives a 50 Ω line ending in 25 Ω.
(a)
What is the load voltage on the first arrival?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Where does it finally settle?
Explain why
Why does a low-impedance driver connected to a long trace and a high-impedance input cause ringing?
The open-ish input reflects almost all of each arriving wave with the same sign, and the low-impedance driver reflects almost all of each returning wave with the opposite sign, because its is close to −1. Each round trip therefore flips the correction's sign while shrinking it only slightly, so the load voltage overshoots, undershoots and overshoots again, converging slowly to the DC value. The product being negative and close to −1 is the condition for strong ringing, and making either end match, or , stops it.
Practice
Keep practicing
11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.