C10 · Lesson 1 · When a connection is a transmission line
Circuit size against wavelength and rise time
Circuit theory assumes a wire has the same voltage all along it at every instant. That's only true if the signal changes slowly compared with the time it takes to travel down the wire. A 50 Hz power cord is thousands of kilometers short of its wavelength, so it's fine. A 30 cm cable carrying a 1 GHz signal holds two whole cycles at once: one end can be at +1 V while the other is at −1 V. Then the wire stops being a node and becomes a transmission line, with reflections, delays and ringing that circuit theory can't predict. The first skill of high-speed and RF design is knowing which case you're in.
- The curve is the voltage along a 30 cm trace (signals travel at m/s on it) at one instant, for a sinusoid at frequency f. Drag the phase to watch the wave move.
- At 10 MHz the whole trace is at nearly the same voltage: lumped circuit theory works. Raise f to a few hundred megahertz and the voltage varies along the trace.
- At 1 GHz and above, the trace holds whole wavelengths. The readout shows the trace's length as a fraction of a wavelength.
Predict
A 100 MHz clock runs along a 30 cm cable in which signals travel at m/s. Should the cable be treated as a transmission line?
Yes. λ = v/f = 2 m, and 0.3 m is 0.15λ. Past about a tenth of a wavelength the phase changes noticeably along the cable, and a square clock's harmonics at 300 and 500 MHz are worse still. Terminate it like a line, or expect ringing.
Name it
Wavelength in a medium
A signal travels along a line at , where is the effective relative permittivity around the conductors: about 2.3 for polyethylene coax (v ≈ 0.66c), and about 3.3 for a microstrip trace on FR-4 circuit board (v ≈ 0.55c). Its wavelength is
and the delay per unit length is 1/v: about 6 ps per millimeter on FR-4 microstrip.
The rules of thumb
- Sinusoids: a connection shorter than about λ/10 can be treated as a lumped node; longer needs line theory. The electrical length says how much phase changes along it.
- Digital edges: what matters is the rise time , not the clock rate. An edge contains significant frequencies up to about . A trace is short enough to ignore when its one-way delay is less than about a sixth of the rise time, so the critical length is
A 1 ns edge on FR-4 has cm. Modern logic with 100 ps edges makes almost every trace a transmission line.
Worked example
A 2.4 GHz Wi-Fi signal runs on FR-4 microstrip ( = 3.3). What is its wavelength on the board, and how long is a 1 cm trace electrically?
Show the solution
- Speed on the board.
- Wavelength.
- Electrical length of 1 cm. One centimeter is a fraction of that wavelength, and a full wavelength is 360° of phase: That's definitely a transmission line.
Answer the wavelength on the board is 6.9 cm, and a 1 cm trace is 0.145λ long, 52° of phase.
Worked example
A logic family has 1 ns rise times. How long can an FR-4 trace be before it needs line treatment?
Show the solution
- Critical length. Use the rule with the FR-4 speed:
- Check with the edge's bandwidth.
- A tenth of a wavelength there. λ/10 at 350 MHz is 4.7 cm, the same order, so both rules say the same thing.
Answer a trace longer than about 2.75 cm needs line treatment.
Worked example
A DDR4 data line at 3200 MT/s toggles at up to 1.6 GHz on FR-4 ( = 3.3). How long a trace is a tenth of a wavelength there?
Show the solution
- Speed on the board.
- Wavelength at 1.6 GHz.
- A tenth of it.
- What that means for routing. Every memory trace on the board is longer than that, which is why DDR routing is done entirely as controlled-impedance lines with length matching.
Answer a tenth of a wavelength is only 1.03 cm.
Check
What is the wavelength of a 433 MHz signal on a line with relative permittivity 2.25?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
How long does a signal take to travel 1 mm on a line with relative permittivity 3.3, in picoseconds?
Write units the way you normally would: 1.5 ps and 0.0015 ns are the same answer.
Check
Edges rise in 0.5 ns on a board with relative permittivity 3.3. About how long can a trace be before it acts as a transmission line (one-way delay = rise time/6)?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
Up to roughly what frequency does an edge with a 0.35 ns rise time carry significant energy?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
What is the electrical length, in degrees, of a 10 cm line at 100 MHz with relative permittivity 3.3?
Check
A cable is 3 m long with a velocity factor of 0.66 (v = 0.66c). How long does a pulse take to reach the far end and reflect back?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
Which connection can safely be treated as an ordinary circuit node?
Check
A 2.4 GHz signal runs on a trace with = 2.5.
(a)
What is its wavelength on the board?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
(b)
How long is a 5 cm trace in degrees of phase?
Check
A signal with 0.5 ns edges runs on a board with = 3.3.
(a)
How long can a trace be before it needs line treatment, by ?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
(b)
What bandwidth do those edges occupy?
Explain why
Why does the rise time of a digital signal, rather than its clock frequency, decide whether a trace is a transmission line?
A transmission-line effect appears when a voltage changes faster than the trace can carry the change from one end to the other. The clock frequency only says how often edges happen; the rise time says how fast each edge changes the voltage. A slow 10 MHz clock with 100 ps edges launches a step that reflects and rings on any trace longer than a couple of centimeters, exactly as a fast clock would. In frequency terms, a sharp edge contains energy up to about , so the relevant wavelength is the one at that frequency, not at the clock rate.
Practice
Keep practicing
11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.