C11 · Lesson 5 · Measuring impedance
Bridges, LCR meters and the parts a component hides
A capacitor labeled 10 µF is also a small resistor and a small inductor, and at some frequency it stops being a capacitor at all. Measuring a component means measuring its impedance, magnitude and phase, at a chosen frequency, and then deciding which simple model it matches there. Bridges did this by balancing against known parts; modern LCR meters measure voltage and current phasors directly and compute it.
- The curve is the impedance magnitude of a real capacitor: capacitance C in series with an equivalent series resistance (ESR) and inductance (ESL).
- At low frequency it falls like an ideal capacitor. At the self-resonant frequency the capacitance and inductance cancel and only the ESR remains; above it, the part behaves as an inductor.
- Raise the ESL, as longer leads do, and the resonance moves down. The readouts give the resonance and the dissipation factor at 1 kHz.
Predict
A 10 µF capacitor has 5 nH of ESL. Roughly where does it stop being capacitive?
About 712 kHz: with L = 5 nH and C = 10 µF. Above that its impedance rises with frequency like an inductor's. That's why decoupling uses several sizes of capacitor in parallel, each covering its own range.
Name it
Bridges
A Wheatstone bridge compares an unknown resistor with known ones: with arms , , and , the detector reads zero when
Because it detects a null, it doesn't depend on the source's accuracy. AC bridges do the same for capacitors and inductors with complex arms.
LCR meters
An auto-balancing bridge, the core of an LCR meter, drives a test signal through the part, holds one end at virtual ground with an amplifier, and measures the voltage across the part and the current through it as phasors. Then , with both magnitude and phase. The meter reports it through a chosen model:
- Series: , natural for low impedances (ESR of large capacitors, inductors' winding resistance).
- Parallel: , natural for high impedances (small capacitors, leakage).
The two describe the same Z at one frequency; with , .
Loss factors
A capacitor's dissipation factor is ; an inductor's quality factor is . They describe the same thing from opposite sides: D = 1/Q.
Fixtures
Test leads and fixtures add their own impedance. Open and short compensation measures the fixture empty and shorted and removes both: for small parts, subtracting the short reading is often enough; for large impedances, the open reading's admittance is subtracted too.
Worked example
A Wheatstone bridge balances with = 1 kΩ, = 2 kΩ and = 4.7 kΩ. What is ?
Show the solution
- Balance condition.
- Why the detector doesn't matter. At balance no current flows through the detector, so its own accuracy doesn't matter, only the known resistors'.
- Accuracy. With 0.1% resistors, the result is good to about 0.2%.
Answer = 9.4 kΩ.
Worked example
A 10 µF capacitor has 0.1 Ω ESR and 5 nH ESL. Find its reactance, D and Q at 1 kHz, and its self-resonant frequency.
Show the solution
- Reactance at 1 kHz.
- D and Q.
- Self-resonance. There the impedance is just the 0.1 Ω ESR.
- Above resonance. Above that it acts as a 5 nH inductor.
Answer at 1 kHz, = 15.9 Ω, D = 0.0063 and Q = 159; it self-resonates at 712 kHz.
Worked example
An inductor measures 1.20 + j15.70 Ω at 100 kHz, and the shorted fixture measures 0.20 + j0.70 Ω. What are the inductor's L and Q?
Show the solution
- Subtract the short.
- Inductance.
- Q.
- Without the correction. Q would read 13.1 and L 25.0 µH: small parts need the fixture removed.
Answer L = 23.9 µH and Q = 15.
Check
A Wheatstone bridge balances with = 1 kΩ, = 2 kΩ and = 3.3 kΩ.
(a)
What is ?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
(b)
What does the detector read at balance?
Check
A 10 µF capacitor has 0.01 Ω ESR, measured at 10 kHz.
(a)
What is its dissipation factor?
(b)
And its Q?
Check
A 1 µF capacitor has 1 nH of ESL.
(a)
Where is its self-resonance?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
(b)
About what is its impedance at 100 MHz, well above resonance, where the ESL dominates?
Check
A part measures = 2 Ω in the series model, with Q = 5.
(a)
What parallel resistance describes it?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What is its series reactance?
Check
A part measures 1.5 + j12 Ω at 100 kHz; the shorted fixture measures 0.3 + j1 Ω.
(a)
What is its inductance after the short correction?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
And its Q?
Check
Why does a bridge's balance not depend on the accuracy of its source or detector?
Explain why
Why does an LCR meter ask whether to report a part in a series or a parallel model?
At a single frequency, any impedance is just a complex number, and it can be written either as a resistance in series with a reactance or as a conductance in parallel with a susceptance: both are exact at that frequency. They differ in what happens at other frequencies and in which elements stay nearly constant. A large capacitor's loss is mostly the resistance of its leads and foil, which is in series with the capacitance, so the series model gives a resistance that stays put as frequency changes. A small capacitor's loss is mostly leakage through its dielectric, which is in parallel, so the parallel model is the stable one. Choosing the model that matches the physics makes the reported values meaningful away from the test frequency.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.