title: Measuring impedance
heading: Bridges, LCR meters and the parts a component hides
eyebrow: C11 · Lesson 5 · Measuring impedance
xp: 40
---

::: hook
A capacitor labeled 10 µF is also a small resistor and a small inductor, and at some frequency it stops being a capacitor at all. Measuring a component means measuring its impedance, magnitude and phase, at a chosen frequency, and then deciding which simple model it matches there. Bridges did this by balancing against known parts; modern LCR meters measure voltage and current phasors directly and compute it.
:::

::: play
- The curve is the impedance magnitude of a real capacitor: capacitance C in series with an equivalent series resistance (ESR) and inductance (ESL).
- At low frequency it falls like an ideal capacitor. At the **self-resonant frequency** the capacitance and inductance cancel and only the ESR remains; above it, the part behaves as an inductor.
- Raise the ESL, as longer leads do, and the resonance moves down. The readouts give the resonance and the dissipation factor at 1 kHz.
:::

```sim plot
view: graph
x: f = 100..1e9 Hz log
y: Z = 0.001..10000 Ω log
slider: C = 0.1..100 step 0.1 = 10 µF
slider: R = 0.005..1 step 0.005 = 0.1 Ω
slider: L = 0.5..50 step 0.5 = 5 nH
plot: sqrt(R^2 + (2*pi*f*L*1e-9 - 1/(2*pi*f*C*1e-6))^2) | samples: 800 | label: |Z| of the real capacitor
plot: 1/(2*pi*f*C*1e-6) | dashed | label: ideal capacitor
readout: self-resonant frequency, kHz = 1/(2*pi*sqrt(L*1e-9*C*1e-6))/1000 | digits: 4
readout: dissipation factor at 1 kHz = R*2*pi*1000*C*1e-6 | digits: 3
```

::: predict
## A 10 µF capacitor has 5 nH of ESL. Roughly where does it stop being capacitive?

- [ ] 10 kHz
- [x] About 700 kHz
- [ ] About 70 MHz
- [ ] It's capacitive at every frequency

::: reveal
About 712 kHz: $1/(2\pi\sqrt{LC})$ with L = 5 nH and C = 10 µF. Above that its impedance rises with frequency like an inductor's. That's why decoupling uses several sizes of capacitor in parallel, each covering its own range.
:::
:::

::: nameit
## Bridges

A **Wheatstone bridge** compares an unknown resistor with known ones: with arms $R_1$, $R_2$, $R_3$ and $R_x$, the detector reads zero when

$$R_x = R_3\frac{R_2}{R_1}$$

Because it detects a null, it doesn't depend on the source's accuracy. AC bridges do the same for capacitors and inductors with complex arms.

## LCR meters

An **auto-balancing bridge**, the core of an LCR meter, drives a test signal through the part, holds one end at virtual ground with an amplifier, and measures the voltage across the part and the current through it as phasors. Then $Z = V/I$, with both magnitude and phase. The meter reports it through a chosen model:

- **Series**: $R_s + jX_s$, natural for low impedances (ESR of large capacitors, inductors' winding resistance).
- **Parallel**: $G_p + jB_p$, natural for high impedances (small capacitors, leakage).

The two describe the same Z at one frequency; with $Q = \lvert X_s\rvert/R_s$, $R_p = R_s(1 + Q^2)$.

## Loss factors

A capacitor's **dissipation factor** is $D = \text{ESR}/\lvert X_C\rvert = \omega C\,\text{ESR}$; an inductor's quality factor is $Q = \omega L/R$. They describe the same thing from opposite sides: D = 1/Q.

## Fixtures

Test leads and fixtures add their own impedance. **Open and short compensation** measures the fixture empty and shorted and removes both: for small parts, subtracting the short reading is often enough; for large impedances, the open reading's admittance is subtracted too.
:::

::: example
## A Wheatstone bridge balances with $R_1$ = 1 kΩ, $R_2$ = 2 kΩ and $R_3$ = 4.7 kΩ. What is $R_x$?

::: solution
1. **Balance condition.**
   $$\begin{aligned} R_x &= \frac{R_3R_2}{R_1} \\ &= \frac{4.7 \times 2}{1}\ \text{k}\Omega \\ &= 9.4\ \text{k}\Omega \end{aligned}$$
2. **Why the detector doesn't matter.** At balance no current flows through the detector, so its own accuracy doesn't matter, only the known resistors'.
3. **Accuracy.** With 0.1% resistors, the result is good to about 0.2%.

**Answer:** $R_x$ = 9.4 kΩ.
:::
:::

::: example
## A 10 µF capacitor has 0.1 Ω ESR and 5 nH ESL. Find its reactance, D and Q at 1 kHz, and its self-resonant frequency.

::: solution
1. **Reactance at 1 kHz.**
   $$\begin{aligned} X_C &= \frac{1}{2\pi \times 1000 \times 10^{-5}}\ \Omega \\ &= 15.9\ \Omega \end{aligned}$$
2. **D and Q.**
   $$\begin{aligned} D &= 0.1/15.9 \\ &= 0.0063 \\ Q &= 15.9/0.1 \\ &= 159 \end{aligned}$$
3. **Self-resonance.**
   $$\begin{aligned} f_0 &= \frac{1}{2\pi\sqrt{5 \times 10^{-9} \times 10^{-5}}} \\ &= 712\ \text{kHz} \end{aligned}$$
   There the impedance is just the 0.1 Ω ESR.
4. **Above resonance.** Above that it acts as a 5 nH inductor.

**Answer:** at 1 kHz, $X_C$ = 15.9 Ω, D = 0.0063 and Q = 159; it self-resonates at 712 kHz.
:::
:::

::: example
## An inductor measures 1.20 + j15.70 Ω at 100 kHz, and the shorted fixture measures 0.20 + j0.70 Ω. What are the inductor's L and Q?

::: solution
1. **Subtract the short.**
   $$\begin{aligned} Z &= 1.20 + j15.70 \\ &\quad - (0.20 + j0.70) \\ &= 1.00 + j15.00\ \Omega \end{aligned}$$
2. **Inductance.**
   $$\begin{aligned} L &= \frac{15.00}{2\pi \times 10^5}\ \text{H} \\ &= 23.9\ \mu\text{H} \end{aligned}$$
3. **Q.**
   $$\begin{aligned} Q &= \frac{15.0}{1.00} \\ &= 15 \end{aligned}$$
4. **Without the correction.** Q would read 13.1 and L 25.0 µH: small parts need the fixture removed.

**Answer:** L = 23.9 µH and Q = 15.
:::
:::

::: check
kind: parts
given: R1 = 1 | 2.2; R2 = 2 | 4.7 | 10; R3 = 0.47 | 3.3

## A Wheatstone bridge balances with $R_1$ = {R1} kΩ, $R_2$ = {R2} kΩ and $R_3$ = {R3} kΩ.

::: part
answer: R3*R2/R1
unit: kΩ
tolerance: 0.5%

### What is $R_x$?

::: misses
- [R3*R1/R2] Check which ratio the balance condition uses: $R_x = R_3R_2/R_1$.
- [any] $R_3R_2/R_1$.
:::
:::

::: part
answer: 0
unit: V
tolerance: 0

### What does the detector read at balance?

::: misses
- [any] That's what balance means.
:::
:::
:::

::: check
kind: parts
given: C = 1 | 10 | 100; E = 0.01 | 0.1 | 0.5; f = 0.1 | 1 | 10

## A {C} µF capacitor has {E} Ω ESR, measured at {f} kHz.

::: part
answer: 2*pi*f*1e3*C*1e-6*E
tolerance: 0.5%

### What is its dissipation factor?

::: misses
- [any] $D = \omega C\,\text{ESR}$.
:::
:::

::: part
answer: 1/(2*pi*f*1e3*C*1e-6*E)
tolerance: 0.5%

### And its Q?

::: misses
- [any] 1/D.
:::
:::
:::

::: check
kind: parts
given: C = 0.1 | 1 | 22; L = 1 | 5 | 20

## A {C} µF capacitor has {L} nH of ESL.

::: part
answer: 1/(2*pi*sqrt(L*1e-9*C*1e-6))/1e6
unit: MHz
tolerance: 0.5%

### Where is its self-resonance?

::: misses
- [any] $1/(2\pi\sqrt{LC})$.
:::
:::

::: part
answer: 2*pi*100e6*L*1e-9
unit: Ω
tolerance: 0.5%

### About what is its impedance at 100 MHz, well above resonance, where the ESL dominates?

::: misses
- [any] $2\pi fL$.
:::
:::
:::

::: check
kind: parts
given: Rs = 0.5 | 2 | 10; Q = 5 | 20 | 100

## A part measures $R_s$ = {Rs} Ω in the series model, with Q = {Q}.

::: part
answer: Rs*(1 + Q^2)
unit: Ω
tolerance: 0.5%

### What parallel resistance describes it?

::: misses
- [any] $R_p = R_s(1 + Q^2)$.
:::
:::

::: part
answer: Rs*Q
unit: Ω
tolerance: 0.5%

### What is its series reactance?

::: misses
- [any] $X_s = QR_s$.
:::
:::
:::

::: check
kind: parts
given: Rm = 1.5 | 3; Xm = 12 | 30; Rs = 0.1 | 0.3; Xs = 0.5 | 1; f = 100 | 1000

## A part measures {Rm} + j{Xm} Ω at {f} kHz; the shorted fixture measures {Rs} + j{Xs} Ω.

::: part
answer: (Xm - Xs)/(2*pi*f*1e3)*1e6
unit: µH
tolerance: 0.5%

### What is its inductance after the short correction?

::: misses
- [Xm/(2*pi*f*1e3)*1e6] Subtract the fixture's reactance first.
- [any] $(X_m - X_s)/\omega$.
:::
:::

::: part
answer: (Xm - Xs)/(Rm - Rs)
tolerance: 0.5%

### And its Q?

::: misses
- [any] Corrected reactance over corrected resistance.
:::
:::
:::

::: check
kind: choice

## Why does a bridge's balance not depend on the accuracy of its source or detector?

- [ ] Bridges use very accurate sources
- [x] At balance the detector reads zero, and the zero condition depends only on the ratio of the arms
- [ ] The detector is calibrated against the source
- [ ] It does depend on them

::: misses
- [1] Any source works, because it divides out of the balance condition.
- [3] No calibration is needed: the detector only has to recognize zero.
- [4] Only the detector's sensitivity matters, not its accuracy.
:::
:::

::: explain
## Why does an LCR meter ask whether to report a part in a series or a parallel model?

::: model
At a single frequency, any impedance is just a complex number, and it can be written either as a resistance in series with a reactance or as a conductance in parallel with a susceptance: both are exact at that frequency. They differ in what happens at other frequencies and in which elements stay nearly constant. A large capacitor's loss is mostly the resistance of its leads and foil, which is in series with the capacitance, so the series model gives a resistance that stays put as frequency changes. A small capacitor's loss is mostly leakage through its dielectric, which is in parallel, so the parallel model is the stable one. Choosing the model that matches the physics makes the reported values meaningful away from the test frequency.
:::
:::

::: practice
::: check
given: R1 = 1 | 10; R2 = 2 | 5; R3 = 1.5 | 6.8
answer: R3*R2/R1
unit: kΩ
tolerance: 0.5%

## Bridge balance: $R_1$ = {R1}, $R_2$ = {R2}, $R_3$ = {R3} kΩ. $R_x$?

::: misses
- [any] $R_3R_2/R_1$.
:::
:::

::: check
given: C = 4.7 | 47; E = 0.05 | 0.2
answer: 2*pi*1000*C*1e-6*E
tolerance: 0.5%

## D of {C} µF with {E} Ω ESR at 1 kHz?

::: misses
- [any] $\omega C\,\text{ESR}$.
:::
:::

::: check
given: C = 0.1 | 10; L = 2 | 8
answer: 1/(2*pi*sqrt(L*1e-9*C*1e-6))/1e6
unit: MHz
tolerance: 0.5%

## Self-resonance of {C} µF with {L} nH?

::: misses
- [any] $1/(2\pi\sqrt{LC})$.
:::
:::
:::