C11 · Lesson 4 · Multimeters in practice
Loading, burden, four-wire resistance and true RMS
C1 showed that a voltmeter loads the circuit it measures. A bench meter hides several more traps. Its current ranges drop a voltage that can upset the circuit (the burden). Its leads add a fraction of an ohm that swamps the reading of a small resistor unless you use four wires. And on AC, a cheap meter that assumes a sine wave can be wrong by 10% or more on a square wave or a motor drive's chopped output. Knowing what the meter actually does turns its number from a guess into a measurement.
- A 1 A current passes through a small resistor via two leads of resistance each. A two-wire meter measures the voltage at the source end, leads included; a four-wire (Kelvin) meter senses right at the resistor.
- With 0.1 Ω under test and 0.2 Ω leads, the two-wire reading suggests 0.5 Ω: five times too high. The four-wire reading is exact, because its sense wires carry no current.
- Shrink the lead resistance: the two readings converge. Four-wire measurement matters whenever the resistor is comparable to the leads.
Predict
An average-responding meter, calibrated to read correctly on sine waves, measures a ±1 V square wave. What does it display?
1.11 V. It rectifies and averages (giving 1 V for the square wave), then multiplies by 1.11, the ratio of RMS to rectified average for a sine. The square wave's true RMS is 1.00 V, so the reading is 11% high. A true-RMS meter would read 1.00 V.
Name it
Voltage: loading
A meter of input resistance (typically 10 MΩ) across a source of Thévenin resistance reads of the true voltage. Below about 1% error, must be under .
Current: burden
An ammeter is a small shunt resistor; the drop across it, the burden voltage, , is subtracted from the circuit. A meter's 200 mA range might use 1 Ω, dropping 0.1 V at 100 mA, enough to matter in a 1 V circuit.
Resistance: two wires or four
A two-wire measurement passes current through the leads and includes their resistance, . A four-wire (Kelvin) measurement forces current through one pair and senses voltage with another pair that carries no current, so it reads alone. It's standard below about 10 Ω and for sense resistors and windings.
AC: what "RMS" means
The RMS value is , the DC voltage that heats a resistor equally. An average-responding meter instead measures the rectified average and multiplies by 1.11 (, right only for sines). A true-RMS meter computes , up to a stated crest factor (peak over RMS). Useful RMS values:
| Waveform, amplitude A | RMS |
|---|---|
| sine | |
| square (±A) | A |
| triangle | |
| DC plus a sine | |
| pulses of height A, duty D | (crest factor ) |
Worked example
A 0.1 Ω current-sense resistor is measured two-wire with 0.2 Ω leads, then four-wire. What does each read?
Show the solution
- Two-wire. The reading includes both leads: five times the true value.
- Four-wire. It reads the true 0.1 Ω.
- In the sim. The sim shows the same at 1 A: 0.5 V against 0.1 V.
Answer two-wire reads 0.5 Ω, five times the true value, and four-wire reads 0.1 Ω.
Worked example
An average-responding meter measures a triangle wave of 1 V amplitude. What does it read, and what is the true RMS?
Show the solution
- Rectified average. The triangle's rectified average is 0.5 V.
- What the meter shows. It scales the average by the sine's form factor, 1.11:
- True RMS.
- The error. The meter reads 3.8% low.
Answer the meter reads 0.555 V, and the true RMS is 0.577 V, so the meter is 3.8% low.
Worked example
A 5 V supply drives 50 Ω, and a meter on its 200 mA range, with a 1 Ω shunt, measures the current. What does it read, and what is its burden voltage?
Show the solution
- Without the meter.
- With the meter. The shunt adds 1 Ω: The meter's own resistance has changed the circuit by 2.0%.
- Burden voltage. The drop across the shunt:
- In low-voltage circuits. Measure the drop across a known resistor already in the circuit instead.
Answer it reads 98.0 mA, 2.0% below the 100 mA that flows without it, and its burden voltage is 98 mV.
Check
A 1 MΩ meter measures a source with 100 kΩ of Thévenin resistance. By what percentage does it read low?
Check
An ammeter's range uses a 0.1 Ω shunt. What burden voltage does it drop at 100 mA?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A 0.5 Ω resistor is measured two-wire through leads of 0.05 Ω each. What does the meter read?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
An average-responding meter (calibrated for sines) measures waves of amplitude 5 V.
(a)
What does it show for a ±5 V square wave?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What does it show for a triangle wave of amplitude 5 V?
Check
A signal is 2 V DC plus a sine of amplitude 1 V. What does a true-RMS meter on DC+AC coupling read?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
What is the crest factor of a pulse train with duty cycle 0.05?
Check
You need to measure the 0.2 Ω winding resistance of a motor to 1%. What method?
Check
A 0.1 Ω resistor is measured with leads of 0.1 Ω each.
(a)
What does a two-wire measurement read?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
By what percentage is that high?
Check
A 5 V source drives 20 Ω, and an ammeter with 5 Ω of shunt resistance is inserted.
(a)
What does it read?
Write units the way you normally would: 1.5 mA, 1500 µA and 0.0015 A are the same answer.
(b)
What is its error relative to the true current?
Explain why
Why does a four-wire measurement eliminate lead resistance?
In a two-wire measurement the same leads carry the test current and sense the voltage, so the voltage drop across the leads, current times lead resistance, is added to the drop across the resistor. A four-wire meter uses one pair of leads to force the current and a separate pair, connected right at the resistor's terminals, to sense the voltage. The sense leads go into a high-impedance input and carry essentially no current, so there's no drop across them, and the voltage they report is the resistor's alone.
Practice
Keep practicing
11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.