title: Oscilloscope probes
heading: Compensation, loading and the ground lead
eyebrow: C11 · Lesson 9 · Oscilloscope probes
xp: 40
---

::: hook
The probe is part of the circuit the moment it touches it, and part of the measurement too. A standard 10× probe hides a precisely trimmed capacitor that must be adjusted for each scope input, or every square wave looks rounded or spiked. Its tip adds about 10 pF, which at 100 MHz is a load of only 160 Ω. And the clip-on ground lead, a few centimeters of wire, is an inductor that rings with that capacitance, painting oscillations on clean edges. Most "noise" and "ringing" seen on scopes by beginners is the probe, not the circuit.
:::

::: play
- A 10× probe is a 9 MΩ resistor with a trimmer capacitor $C_1$ across it, feeding the scope's 1 MΩ input, which together with the cable has about 90 pF. A 1 kHz square wave from the scope's 50 Ω calibrator output goes in.
- The output is a tenth of the input only if the two RC products match: $C_1$ = 90/9 = 10 pF. Set $C_1$ lower and the corners round off (undercompensated); higher and they overshoot (overcompensated).
- That's what the probe-adjustment screw does, against the scope's built-in square-wave output.
:::
:::

```sim circuit
V1 src 0 square 0 1 1k  @ 0,0 down
RS src in 50            @ 0,0 right
R1 in out 9M            @ 2,0 right
C1 in out 10p           @ 2,-1 right
R2 out 0 1M             @ 4,0 down
C2 out 0 90p            @ 5,0 down
slider: C1 3p..30p log
scope: v(in), v(out)
time: 0..2m s
```

::: predict
## A 10× probe feeds a scope whose input plus cable totals 90 pF across 1 MΩ. What should the probe's compensation capacitor across its 9 MΩ be?

- [ ] 90 pF
- [x] 10 pF
- [ ] 1 pF
- [ ] 810 pF

::: reveal
10 pF. The probe is a divider of two parallel RC pairs, and it divides by the same ratio at every frequency only if their time constants match: $9\text{ MΩ} \times C_1 = 1\text{ MΩ} \times 90\text{ pF}$. The capacitive divider then gives the same 10:1 as the resistive one.
:::
:::

::: nameit
## The compensated divider

A 10× probe's tip has $R_1$ = 9 MΩ in parallel with $C_1$; the scope has $R_2$ = 1 MΩ in parallel with $C_2$ (input plus cable). The division is flat with frequency when

$$R_1C_1 = R_2C_2 \quad\Rightarrow\quad C_1 = \frac{C_2}{9}$$

Undercompensated (C₁ too small) rounds square-wave corners; overcompensated (too large) spikes them. Adjust against the scope's calibrator before measuring anything with edges.

## Loading

The probe presents 10 MΩ in parallel with about 10 pF (a 1× setting is far worse: about 1 MΩ and 100 pF, and much lower bandwidth). The capacitance dominates at high frequency:

$$\lvert Z\rvert = \frac{1}{2\pi fC}$$

which is 160 Ω at 100 MHz. On a node driven through a source resistance $R_s$, it adds a rise time of about $2.2R_sC$.

## The ground lead

The ground clip's wire, about 1 nH per millimeter, forms a series LC with the tip capacitance that rings at

$$f = \frac{1}{2\pi\sqrt{LC}}$$

so a 15 cm lead (150 nH) with 10 pF rings near 130 MHz on every fast edge. A short ground spring at the tip pushes the resonance far above the signal.

## Other probes

**Active** probes (an amplifier at the tip, ~1 pF) for fast signals, **differential** probes for measurements not referenced to ground (lesson 17), and **current** probes (clamp-on, Hall effect or transformer) for current without breaking the circuit.
:::

::: example
## A 10 pF probe touches a node driven through 50 Ω. What rise time does it add, and what is its impedance at 100 MHz?

::: solution
1. **Rise time added.**
   $$\begin{aligned} t_r &= 2.2 \times 50\ \Omega \times 10\ \text{pF} \\ &= 1.1\ \text{ns} \end{aligned}$$
2. **Impedance at 100 MHz.**
   $$\begin{aligned} X_C &= \frac{1}{2\pi \times 10^8 \times 10^{-11}}\ \Omega \\ &= 159\ \Omega \end{aligned}$$
3. **What that means.** That's a significant load on a 50 Ω node, which is why fast nodes use low-capacitance active probes.

**Answer:** it adds 1.1 ns of rise time, and its impedance at 100 MHz is 159 Ω.
:::
:::

::: example
## A probe with 10 pF at its tip has a 15 cm ground lead. At what frequency will it ring?

::: solution
1. **Lead inductance.** A 15 cm lead is about 150 nH.
2. **Ringing frequency.**
   $$\begin{aligned} f &= \frac{1}{2\pi\sqrt{150\ \text{nH} \times 10\ \text{pF}}} \\ &= 130\ \text{MHz} \end{aligned}$$
3. **With a ground spring.** A 1 cm ground spring (10 nH) moves it to about 500 MHz.

**Answer:** it rings at about 130 MHz.
:::
:::

::: example
## A 10× probe has 9 MΩ in its tip. The scope input and cable together present 1 MΩ in parallel with 100 pF. What tip capacitance compensates it?

::: solution
1. **Equal time constants.** The divider is flat with frequency when both halves have the same time constant:
   $$9\ \text{M}\Omega \times C_\text{tip} = 1\ \text{M}\Omega \times 100\ \text{pF}$$
2. **Solve for the tip capacitance.**
   $$\begin{aligned} C_\text{tip} &= \frac{100\ \text{pF}}{9} \\ &= 11.1\ \text{pF} \end{aligned}$$
3. **Adjusting it.** A trimmer on the probe adjusts it until a square wave's corners are neither rounded nor peaked.

**Answer:** a tip capacitance of 11.1 pF compensates it.
:::
:::

::: check
given: C2 = 60 | 90 | 120; k = 9 | 99
answer: C2/k
unit: pF
tolerance: 0.5%

## A probe divides by {k} + 1 with a tip resistor {k} times the scope's 1 MΩ. The scope input and cable total {C2} pF. What compensation capacitance does the tip need?

::: right
Right. $C_2$ divided by {k}: {answer} pF.
:::

::: misses
- [C2*k] The tip's larger resistance needs a proportionally smaller capacitor.
- [any] Not yet. Match $R_1C_1 = R_2C_2$.
:::
:::

::: check
given: f = 10 | 100 | 500; C = 1 | 10 | 15
answer: 1/(2*pi*f*1e6*C*1e-12)
unit: Ω
tolerance: 0.5%

## A probe's tip capacitance is {C} pF. What is its impedance at {f} MHz?

::: right
Right. $1/(2\pi fC)$ = {answer} Ω.
:::

::: misses
- [1/(f*1e6*C*1e-12)] Include 2π.
- [any] Not yet. $1/(2\pi fC)$.
:::
:::

::: check
given: Rs = 25 | 100 | 1000; C = 1 | 10 | 15
answer: 2.2*Rs*C*1e-3
unit: ns
tolerance: 0.5%

## A node is driven through {Rs} Ω. How much rise time does a {C} pF probe add?

::: right
Right. $2.2R_sC$ = {answer} ns.
:::

::: misses
- [Rs*C*1e-3] The 10 to 90% rise of an RC is 2.2 time constants.
- [any] Not yet. $2.2R_sC$.
:::
:::

::: check
given: L = 10 | 50 | 150; C = 2 | 10 | 15
answer: 1/(2*pi*sqrt(L*1e-9*C*1e-12))/1e6
unit: MHz
tolerance: 0.5%

## A probe with {C} pF at its tip has {L} nH of ground lead. At what frequency does it ring?

::: right
Right. $1/(2\pi\sqrt{LC})$ = {answer} MHz.
:::

::: misses
- [1/sqrt(L*1e-9*C*1e-12)/1e6] That's in radians per second; divide by 2π.
- [any] Not yet. $1/(2\pi\sqrt{LC})$.
:::
:::

::: check
given: V = 0.25 | 1.2 | 4.8
answer: 10*V
unit: V
tolerance: 0.5%

## A 10× probe is used, but the scope's channel is set for a 1× probe. The screen shows {V} V. What is the real voltage?

::: right
Right. The probe divided by 10: {answer} V.
:::

::: misses
- [V/10] The probe attenuates; the real signal is larger than shown.
- [any] Not yet. Multiply by the probe's ratio.
:::
:::

::: check
given: l = 20 | 75 | 150
answer: l
unit: nH
tolerance: 0.5%

## About how much inductance does a {l} mm ground lead have, at roughly 1 nH per millimeter?

::: right
Right. About {answer} nH.
:::

::: misses
- [any] Not yet. Length in millimeters × 1 nH.
:::
:::

::: check
kind: choice

## A square wave from the scope's calibrator shows overshoot and a slow decay at each corner through a 10× probe. What's wrong?

- [ ] The probe is undercompensated
- [x] The probe is overcompensated: its trimmer capacitance is too large
- [ ] The ground lead is too short
- [ ] The scope's bandwidth is too low

::: misses
- [1] Undercompensation rounds the corners instead.
- [3] A short ground lead helps; a long one causes fast ringing, not a slow decay.
- [4] Too little bandwidth rounds edges; it doesn't add a slow overshoot.
:::
:::

::: check
kind: parts
given: C = 8 | 15; R = 25 | 50 | 500; f = 10 | 100

## A probe with {C} pF at its tip touches a node driven through {R} Ω.

::: part
answer: 2.2*R*C/1000
unit: ns
tolerance: 0.5%

### What 10–90% rise time does it add?

::: misses
- [any] $2.2RC$.
:::
:::

::: part
answer: 1/(2*pi*f*1e6*C*1e-12)
unit: Ω
tolerance: 0.5%

### What is its impedance at {f} MHz?

::: misses
- [any] $1/(2\pi fC)$.
:::
:::
:::

::: check
kind: parts
given: Rt = 9 | 99; Cin = 80 | 120

## A probe's tip has {Rt} MΩ, and the scope and cable present 1 MΩ in parallel with {Cin} pF.

::: part
answer: Cin/Rt
unit: pF
tolerance: 0.5%

### What tip capacitance compensates it?

::: misses
- [any] Equal time constants: $R_tC_t = R_\text{in}C_\text{in}$.
:::
:::

::: part
answer: Rt + 1
tolerance: 0.5%

### What is the probe's attenuation factor?

::: misses
- [any] $(R_t + 1\text{ MΩ})/1\text{ MΩ}$.
:::
:::
:::

::: explain
## Why must a 10× probe's two RC time constants match?

::: model
At low frequencies the capacitors are open and the probe divides by the resistor ratio, 9 MΩ to 1 MΩ, giving 10:1. At high frequencies the capacitors take over and it divides by the capacitor ratio instead, the larger capacitance getting the smaller share of the voltage. Only if both ratios are the same, which happens when $R_1C_1 = R_2C_2$, is the division 10:1 at every frequency in between. Otherwise the fast parts of a signal, its edges, are scaled differently from the slow parts, its flat tops, and square waves come out rounded or spiked.
:::
:::

::: practice

::: check
given: C2 = 60 | 75 | 90 | 100 | 110 | 135
answer: C2/9
unit: pF
tolerance: 0.5%

## Compensation for a 10× probe on a {C2} pF input?

::: misses
- [any] $C_2/9$.
:::
:::

::: check
given: f = 10 | 50 | 100 | 200 | 250 | 500; C = 10
answer: 1/(2*pi*f*1e6*C*1e-12)
unit: Ω
tolerance: 0.5%

## Impedance of {C} pF at {f} MHz?

::: misses
- [any] $1/(2\pi fC)$.
:::
:::

::: check
given: L = 10 | 25 | 50 | 75 | 100 | 150; C = 8
answer: 1/(2*pi*sqrt(L*1e-9*C*1e-12))/1e6
unit: MHz
tolerance: 0.5%

## Ringing frequency of {L} nH with {C} pF?

::: misses
- [any] $1/(2\pi\sqrt{LC})$.
:::
:::
:::