C11 · Lesson 23 · Sensors and signal conditioning
From a physical quantity to a clean voltage for the ADC
Most sensors produce tiny, awkward signals. A strain gauge changes its resistance by a fraction of a percent; a thermocouple produces about 40 µV per degree; a platinum thermometer changes by 0.4% per degree. Before an ADC can read them, they need signal conditioning: excitation, a bridge to turn small resistance changes into a voltage centered on zero, an instrumentation amplifier to raise it to the converter's range while rejecting common-mode noise, and a filter to stop aliasing. Each stage is a short calculation, and getting the gain right is what decides how many of the converter's bits are actually used.
- A strain gauge with gauge factor GF sits in one arm of a bridge excited by ; the other three arms are fixed resistors. The curve is the bridge output against strain, in microstrain (µε).
- For small strains the output is close to the straight line (dashed). At large strains the exact output bends away: a quarter bridge is slightly nonlinear.
- The readout gives the output at 1000 µε and the gain needed to bring it to a 3.3 V converter's full scale.
Predict
A quarter-bridge strain gauge (GF = 2) with 5 V excitation sees 1000 µε. About what voltage does the bridge produce?
2.5 mV: . A large strain for steel gives a signal smaller than the hum on a typical lab bench, which is why bridges use instrumentation amplifiers with high common-mode rejection.
Name it
Common sensors
| Sensor | Response | Typical sensitivity |
|---|---|---|
| strain gauge | GF ≈ 2 | |
| thermocouple (type K) | between hot and cold junctions | S ≈ 41 µV/°C |
| platinum RTD (Pt100) | = 100 Ω, α = 0.00385 /°C | |
| thermistor | −4%/°C near room temperature |
A thermocouple measures the difference between its hot junction and the cold junction where it meets copper, so the cold junction's temperature must be measured separately and added: cold-junction compensation.
The Wheatstone bridge
Four resistors, excited across one diagonal and read across the other, output zero at balance. One active gauge (a quarter bridge) gives
Two or four active gauges (half and full bridges) double or quadruple that and cancel temperature effects.
The conditioning chain
Excitation → bridge → instrumentation amplifier → anti-aliasing filter → ADC. Choose the gain so the largest expected signal nearly fills the converter's range:
and watch for self-heating: a current I through a sensor of resistance R dissipates , warming it by that power times its thermal resistance.
Worked example
A Pt100 RTD reads 100 °C. What is its resistance, and how much does a 1 mA excitation heat it?
Show the solution
- Resistance at 100 °C.
- Power dissipated.
- Self-heating. With a typical 0.2 °C/mW in still air, that's a 0.03 °C error.
Answer 138.5 Ω, and the excitation heats it by about 0.03 °C.
Worked example
A quarter bridge (5 V, GF = 2) must give a 3.3 V ADC full scale at 2000 µε. What gain is needed?
Show the solution
- Bridge output at 2000 µε.
- Gain.
- Building it. An instrumentation amplifier with a gain resistor sets that in one stage.
Answer a gain of 660.
Worked example
A type K thermocouple (about 41 µV/°C) reads 1.00 mV, and its cold junction is at 25 °C. What is the hot junction's temperature?
Show the solution
- Temperature difference. The voltage measures the difference between the junctions:
- Add the cold junction.
- Without compensation. Forgetting cold-junction compensation would read 24.4 °C, wrong by exactly the room temperature.
Answer the hot junction is at 49.4 °C.
Check
A 350 Ω strain gauge with GF = 2 is strained by 2000 µε. By how many milliohms does its resistance change?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A quarter bridge is excited by 5 V, with a GF = 2 gauge at 3000 µε. About what is its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A sensor's largest output is 2 mV and the ADC's full scale is 3.3 V. What gain fills the range?
Check
A thermocouple with a sensitivity of 41 µV/°C has its hot junction 100 °C above its cold junction. What voltage does it produce?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
What is a Pt100 RTD's resistance at 25 °C (α = 0.00385)?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A 100 Ω sensor carries 1 mA and has a thermal resistance of 0.5 °C/mW. How much does it heat itself?
Check
A thermocouple reads 2.05 mV (41 µV/°C) with its connector at 25 °C. What is the hot junction's temperature?
Check
A Pt100 RTD (α = 0.00385/°C) is at 50 °C, excited with 0.5 mA; its self-heating is 5 mW/°C.
(a)
What is its resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
How much does the excitation heat it?
Check
A quarter bridge with 5 V excitation and gauge factor 2.1 sees 500 µε.
(a)
What is its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
What gain brings it to 3.3 V?
Explain why
Why are strain gauges almost always read in a bridge instead of by measuring their resistance directly?
A strain gauge's resistance changes by tiny fractions: resolving one microstrain on a 350 Ω gauge means seeing a 0.7 mΩ change, two parts per million, on top of a large value, which needs extraordinary accuracy. A bridge subtracts the large unchanging part by comparing the gauge with fixed resistors, so its output is zero at rest and proportional to the change alone. That small voltage can then be amplified with high gain without saturating, and the bridge's differential output lets an instrumentation amplifier reject the common-mode noise picked up by the wiring.