C11 · Lesson 13 · Spectrum analyzers
Resolution bandwidth, noise floors and decibels
A scope shows a signal's shape; a spectrum analyzer shows what frequencies it contains and how strong each is, across a range of 100 dB or more, from a strong carrier down to a harmonic a millionth of its power. Its key setting is the resolution bandwidth, the width of the filter it sweeps across the band. A narrow filter separates tones that are close together and lowers the noise it shows, so it can see weak signals, but it makes the sweep painfully slow. Every measurement is a choice of that tradeoff.
- The trace is what an analyzer shows for a −30 dBm tone at 0 and a −60 dBm tone D kHz away, on a noise background of −160 dBm/Hz, with resolution bandwidth RBW.
- With a wide RBW, the weak tone is buried in the strong one's skirt and in noise. Narrow it: the two separate, and the noise floor drops by 10 dB for every factor of 10.
- The readouts give the displayed noise floor and the rough sweep time for a 1 MHz span, which grows as .
Predict
An analyzer's resolution bandwidth is reduced from 10 kHz to 100 Hz. What happens to its displayed noise floor?
It drops 20 dB. The filter passes noise power in proportion to its bandwidth, and 100 Hz is a hundredth of 10 kHz: dB less noise. A sinusoid's power, all at one frequency, passes either filter unchanged, so the signal stands 20 dB further out of the noise.
Name it
How it works
A swept analyzer mixes the input down and passes it through a narrow resolution bandwidth (RBW) filter while sweeping the frequency, displaying the power that gets through, in dBm. FFT analyzers compute the same from sampled data. A tone appears as the RBW filter's shape centered on its frequency.
RBW tradeoffs
- Resolution: two tones closer than about the RBW merge; a small tone near a large one also needs the filter's skirt to fall off fast enough.
- Noise floor: noise of density (dBm/Hz) shows up as dBm. The thermal floor is −174 dBm/Hz at room temperature, plus the analyzer's noise figure.
- Speed: a swept analyzer needs about seconds, with k around 2 to 3.
Units
- dBm: power relative to 1 mW. 0 dBm is 1 mW; +30 dBm is 1 W, often the most an analyzer's input survives.
- dBc: relative to the carrier. A harmonic at −45 dBm next to a 0 dBm carrier is −45 dBc.
- The signal-to-noise ratio read off the screen is the signal in dBm minus the floor in dBm, which depends on the RBW used.
Worked example
An analyzer has a noise figure of 8 dB. What noise floor does it show at 1 kHz RBW?
Show the solution
- Noise floor.
- What it hides. A signal below about −136 dBm is invisible at that setting.
- A narrower RBW. Dropping to 100 Hz RBW would reveal signals down to about −146 dBm.
Answer the noise floor is −136 dBm.
Worked example
How long does a 1 MHz span take at 1 kHz RBW, with k = 2?
Show the solution
- Sweep time at 1 kHz RBW.
- At 100 Hz RBW. The price of a 10 dB lower floor is a hundred times the sweep time.
Answer the sweep takes 2 s.
Worked example
A spectrum analyzer's noise floor is −93 dBm, and with a weak signal present it reads −90 dBm. What is the signal's true power?
Show the solution
- Signal plus noise. The display shows signal plus noise, so subtract in power.
- Subtract in milliwatts.
- Back to dBm.
- How big the error is. A signal right at the noise floor reads 3 dB high; one 10 dB above it reads only 0.4 dB high.
Answer the signal's true power is −93.0 dBm.
Check
Noise of density −160 dBm/Hz is viewed with a 100 Hz resolution bandwidth. What floor is displayed?
Check
The RBW is made 10 times narrower. By how many dB does the noise floor fall?
Check
About how long does a 1 MHz span take at 0.3 kHz RBW, with k = 3?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A carrier is at 0 dBm and its second harmonic at −55 dBm. What is the harmonic level in dBc?
Check
How much power is 7 dBm?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A −40 dBm tone is viewed on an analyzer with a 5 dB noise figure at 100000 Hz RBW. What SNR does the display show?
Check
Two tones 5 kHz apart must be seen separately. Which RBW should you choose?
Check
A spectrum analyzer with a 10 dB noise figure uses a 10 Hz resolution bandwidth.
(a)
What noise floor does it show?
(b)
And with the RBW ten times narrower?
Check
An analyzer reads −88 dBm on a weak signal with a −93 dBm noise floor.
(a)
What is the signal's true power?
(b)
By how much does the display overstate it?
Explain why
Why does narrowing the resolution bandwidth make weak signals easier to see?
A sinusoid puts all its power at one frequency, so any filter wide enough to include that frequency passes all of it, however narrow. Noise spreads its power evenly across frequency, so a filter passes noise power in proportion to its width. Narrowing the RBW therefore leaves the signal unchanged while cutting the noise that shares the display with it, lowering the floor by 10 dB per factor of 10. The cost is time: the narrower filter takes longer to respond, so the sweep must slow down as the square of the reduction.
Practice
Keep practicing
11 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.