C12 · Lesson 30 · I²C and a temperature sensor
Two wires, many devices, and a conversation for each read
A board with a temperature sensor, an accelerometer, a clock chip and a memory would run out of pins if each had its own wires. I²C connects them all to the same two: a data line (SDA) and a clock line (SCL). Every device has an address, and every exchange is a short conversation the controller starts: a start signal, an address, a direction, then bytes, each acknowledged by whoever received it. Reading one register of a sensor takes about half a millisecond at the standard 100 kHz, and the waveforms are simple enough to read by eye on a logic analyzer.
- The program reads the temperature sensor at address 0x48 every 100 ms and prints its reading in hundredths of a degree. Run it, then look at the SDA and SCL lanes (zoomed to the first read).
- Find the pieces: SDA falling while SCL is high (start), 9 clocks for the address byte with its write bit and the sensor's acknowledgment, 9 for the register number, a repeated start, 9 for the address with the read bit, then two data bytes, and SDA rising while SCL is high (stop).
- Change the sensor's temperature slider and run again: the printed value follows it.
Predict
A device's 7-bit address is 0x48. What byte does the controller send to start reading from it?
0x91: the address goes in the top 7 bits and the direction in bit 0 (1 for read), so . Writing would send 0x90. Datasheets sometimes quote these 8-bit forms, a frequent source of confusion.
Name it
The bus
SDA and SCL are open-drain: devices only pull them low, and pull-up resistors bring them high. The controller drives SCL; data changes only while SCL is low, except for two special events:
- start: SDA falls while SCL is high;
- stop: SDA rises while SCL is high.
Each byte is 8 bits, most significant first, followed by a ninth clock in which the receiver pulls SDA low to acknowledge (ACK) or leaves it high (NACK). A controller reading NACKs the last byte to say it's done.
Addresses and transactions
Every device has a 7-bit address; the first byte after a start is the address shifted left with the direction in bit 0 (0 write, 1 read). If no device answers, the address byte is NACKed. Reading a register is a write then a read:
start, address+W, register, repeated start, address+R, data..., stop
Standard mode is 100 kHz; fast mode 400 kHz. Each byte takes 9 clocks.
Pull-ups and speed
The bus's capacitance C (devices plus wiring) charges through the pull-up R. From 30% to 70% of the supply takes , and the standard allows at most 1000 ns at 100 kHz and 300 ns at 400 kHz, so
This sensor
A TMP102-style sensor returns two bytes: a 12-bit two's-complement temperature, left-justified, in units of 1/16 °C (0.0625 °C).
Worked example
The sensor returns 0x19 then 0x80. What's the temperature?
Show the solution
- Join the bytes. Together they make 0x1980.
- Shift right by 4.
- Check the sign. Bit 11 is 0, so it's positive.
- Scale to degrees.
Answer 25.5 °C.
Worked example
A 400 kHz bus has 100 pF of capacitance. What's the largest pull-up that meets the 300 ns rise time?
Show the solution
- Solve the rise time for R.
- Pick a standard value. A standard 3.3 kΩ works.
- A bigger pull-up. A 10 kΩ pull-up would only manage about 100 kHz on that bus.
Answer 3.54 kΩ, so a standard 3.3 kΩ.
Worked example
Reading a 2-byte register from an I²C sensor at 100 kHz takes an address byte, a register byte, a repeated start with the address again, and two data bytes. About how long?
Show the solution
- Count the byte bits. Five bytes of 9 bits each (8 data plus acknowledge):
- Add the bus conditions. About 3 more for the start, repeated start and stop make 48 bit-times.
- Time at 100 kHz. Each bit-time is 10 µs:
- At 400 kHz. It's 120 µs.
- What it means. Reading many sensors over I²C at 100 kHz adds up quickly.
Answer about 480 µs at 100 kHz, and 120 µs at 400 kHz.
Check
A device's address is 48. What's the first byte after start to 0? (0 write, 1 read)
Check
A positive reading arrives as 19, 00. What's the temperature?
Check
In 12-bit two's complement at 0.0625 °C per count, what raw value does −10 °C produce?
Check
At 100 kHz, a transaction sends 2 bytes (each 9 clocks) plus about one clock for the start and stop. How long does it take?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
The bus has 50 pF and must rise in 300 ns. What's the largest pull-up?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
Check
A read ends with the controller sending NACK after the last byte. Why?
Check
A temperature sensor sits somewhere on the I²C bus. Scan every address from 0x08 to 0x77 and print the one that acknowledges.
C on the course's RISC-V board (10 MHz, no floating point). #include "board.h" for the registers; print(x) shows a number. Tab indents; press Esc and then Tab to move on.
Check
The sensor at 0x48 is below freezing. Read it and print its temperature in °C, handling negative values.
MicroPython on the course's board: machine (Pin, PWM, ADC, DAC, UART, I2C, SPI, Timer, WDT) and time. Each call into the hardware takes about 40 µs. Tab indents; press Esc and then Tab to move on.
Check
An I²C bus has 50 pF and must rise in 300 ns.
(a)
What is the largest pull-up?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
(b)
What current does a device sink pulling it low?
Check
A temperature sensor returns bytes 50 then 128; the reading is the 16-bit value shifted right by 4, in sixteenths of a degree, and positive here.
(a)
What is the 12-bit reading?
(b)
What temperature?
Explain why
How can many devices share one SDA wire without fighting over it?
SDA is open-drain: no device ever drives it high, they can only pull it low or let go, and a pull-up resistor raises it when everyone has let go. If two devices disagree, the one pulling low simply wins, and no current fights between outputs. That's what makes acknowledgment work: the receiver pulls the line low during the ninth clock while the sender lets go. It also lets several controllers detect each other: one that sends a 1 but sees a 0 knows another is talking, and backs off. Only the device whose address was sent takes part in a transaction, so the others ignore the bus until the next start.
Practice
Keep practicing
12 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.